Repository navigation
Events and Actions
← Documentation · Automation examples · Protocol reference
Prefer entity-targeted actions for normal controls. Replace the example IDs with your own.
| Action | TecomHA behaviour |
|---|---|
alarm_control_panel.alarm_arm_away |
Validated area arming |
alarm_control_panel.alarm_arm_home |
Stay arm |
alarm_control_panel.alarm_arm_custom_bypass |
Force arm; does not isolate unsealed inputs |
alarm_control_panel.alarm_disarm |
Disarm |
lock.open |
Momentary DGP door release |
lock.unlock |
Latched DGP door unlock |
lock.lock |
DGP door lock |
switch.turn_on / switch.turn_off
|
Relay control |
button.press on Sync Users Now
|
User name download for that button's panel |
Example action blocks for Developer Tools → Actions or an automation:
action: alarm_control_panel.alarm_arm_away
target:
entity_id: alarm_control_panel.house_alarm
data: {}action: lock.open
target:
entity_id: lock.front_entry
data: {}See the alarm control panel and lock documentation for Home Assistant's standard actions. The entity guide explains Tecom-specific behaviour.
In Developer Tools → Events, listen to either:
tecom_challengerplus_ctplus_eventtecom_challengerplus_event
The same decoded panel event is fired under both names for compatibility. Use one in an automation to avoid handling the same event twice.
Illustrative door-open payload:
event_type: tecom_challengerplus_ctplus_event
data:
entry_id: "your_config_entry_id"
code: 165
code_hex: "0xA5"
object: 17
object_hex: "0x0011"
raw: "0f0c68c8389fa511000000000000"
text: "Door 17 Open"
message: "Door 17 Open"The entry_id identifies the panel configuration entry. Additional fields depend on the event. They can include area, user, user_name, last_user and last_user_name. A system-generated release can have no user. Do not interpret the absence of a name as proof that a credential was not used; name sync may simply be unavailable.
Where available, CTPlus event-table metadata is included:
eventtable_descriptioneventtable_response_requiredeventtable_required_2nd_responseeventtable_send_reset_to_paneleventtable_restore_event_codeeventtable_update_statuseventtable_status_options
The protocol reference lists known codes. Prefer ordinary entity state triggers for simple open/closed, relay or alarm automations.
Door event entities expose access granted, egress, confirmed card/void denials, forced and open-too-long activity. The entity state is the time of the event; event_type is an attribute. Triggering only on a change of the event_type attribute can miss repeated events of the same type. Use the event entity's timestamp state when building an event-entity automation.
Multiple panels: events include entry_id, and each door entity checks both the panel entry and door number. Event-bus automations should also filter by entry_id when several panels share object numbers.
The integration records tecom_challengerplus_access_activity for supported events on loaded door access entities. It includes entry_id, entity_id, device_id when registered, name, message, icon, code, event_type and door. Entity/device identifiers are present before Home Assistant filters Activity. The message is a snapshot of the name available at the time; it does not repeat the door's entity label.
| Event | Example message |
|---|---|
| Credentialed grant | Access granted - J. Smith |
| System release | Access granted - System |
| Exit button | Access granted (exit button) |
| Explicit void denial | Access denied - J. Smith (void) |
| Card rejection | Access denied - Card rejected |
Without a synced name, an identified user is shown as User 1041. Card rejection 0x4B does not identify a user or distinguish unknown from voided cards. The decoded general event has denial_reason: card_rejected, an empty raw and raw_redacted: true. Explicit 0x8B has denial_reason: void. See confirmed denial layouts.
Denials and anonymous releases do not overwrite the last successful credentialed access. Automations that mean a successful access should filter access_granted or access_granted_egress; a timestamp change can now also represent a denial. Entity IDs remain unchanged.
Home Assistant can show its native event-type row alongside the named entry. History remains a timestamp timeline, and old Activity is not rewritten. Do not exclude the access entity to hide the native row, as that can hide both. The generic “Event detected” label alone does not establish that the integration reloaded.
All names below use the tecom_challengerplus. prefix.
| Action | Purpose and scope |
|---|---|
dump_debug |
Writes a debug JSON file. Optional entry_id; omitting it dumps all loaded panels. |
download_users |
Downloads user names for all loaded panels. Use the per-panel button for a targeted download. |
force_arm_area |
Takes area and force-arms that number on every loaded panel. Prefer the entity-targeted custom-bypass action when selecting one panel. |
request_full_sync |
Requests a full status refresh for the selected panel. |
reinitialize_session |
Re-sends the CTPlus session initialisation for the selected panel. |
reset_comms_path_event_buffer |
Maintenance-only reset/clear of the selected communication path's event buffer. |
retrieve_events |
Legacy alias for the buffer reset above. It clears/resets the buffer; it is not a normal event download. |
send_raw_hex |
Sends a raw payload for protocol testing. Takes hex and optional entry_id. |
test_event |
Fires the internal tecom_challengerplus_test event with an optional note. |
request_full_sync, reinitialize_session, both buffer-reset names and send_raw_hex accept entry_id. It is required for these actions when multiple panels are loaded. Use the configuration entry identifier, not an entity ID; the action raises an error rather than guessing which panel to use.
Do not put buffer resets into routine startup or recovery automations: they discard queued event information. Sending raw commands also requires a known, verified payload.
For a single-panel installation, a manual status refresh is:
action: tecom_challengerplus.request_full_sync
data: {}To capture diagnostic data without changing the event queue:
action: tecom_challengerplus.dump_debug
data: {}See Troubleshooting for locating and reviewing the resulting file.