Skip to content

Entities

Josh edited this page Sep 4, 2026 · 1 revision

Entities and supported behaviour

← Documentation · Configuration · Events and actions

These features describe CTPlus / Management Software mode. Which entities appear depends on the configured object counts and ranges.

Panel object Home Assistant entity Purpose
Area alarm_control_panel Arm, stay arm, force arm, disarm and alarm status
Input / zone binary_sensor Sealed or active state, with alarm information in attributes
DGP door lock Lock, unlock and momentary release
Door contact binary_sensor Physical open/closed state reported by the panel
RAS / keypad Read-only lock/contact entities Limited status; no door control
Relay / output switch On/off control and status
Door activity event Access grants, confirmed denials, egress and door exceptions
Last event sensor Latest panel event and diagnostic attributes
Sync Users Now button Download user names for the associated panel

Alarm areas

Each configured area has its own alarm control panel entity.

Action Behaviour
Arm away Validated arming; the panel can refuse if inputs are unsealed
Arm home / stay Stay-arms the area using the panel's programmed behaviour
Force arm Arms regardless of unsealed inputs
Disarm Disarms the area

Force arm does not isolate unsealed inputs. An open input may immediately trigger an alarm. Home Assistant exposes this as alarm_arm_custom_bypass, but its behaviour here is the panel's force-arm command.

Changes made from a keypad, CTPlus or another panel client are reflected in Home Assistant when the corresponding events arrive. An area in alarm reports triggered; its alarm_inputs and alarm_input_names attributes identify the inputs reported in alarm.

Stay-armed areas report armed_home. The polled status word cannot distinguish stay from away, so an area already stay-armed before Home Assistant starts can initially show armed_away until an appropriate arm/disarm event is received. A known stay-arm state is preserved across subsequent polling.

Inputs and zones

  • On means unsealed / active.
  • Off means sealed / normal.

Inputs update from event traffic and status recalls. Motion detectors that do not send seal events need runtime input polling; a sensor's response speed then depends on the polling interval.

Alarm state is separate from seal state. The in_alarm attribute reports whether the input is in alarm; when applicable, alarm_area and alarm_area_name identify its area. Raw status attributes are available for troubleshooting. The status-bit interpretation is documented in the protocol reference.

Doors: control and contact state

A door's lock state and physical position are different. An unlocked door can still be closed, and a locked output does not prove the door has closed.

Use the lock entity for control and the Door Contact binary sensor for open/closed status. The contact indication depends on the panel's contact wiring and programming. The companion door tile can also use a separately selected reed/input sensor.

Action Result
Open Door / lock.open Momentary access grant using the panel's programmed release behaviour; does not change the latched lock mode
Unlock / lock.unlock Leaves the door unlocked until a later lock command or panel logic changes it
Lock / lock.lock Requests the locked mode

DGP doors (17+) support these controls. RAS doors/keypads (1–16) are read-only because a RAS may be an arming station rather than a door controller. RAS status is a limited interpretation, not a substitute for a confirmed physical contact.

DGP lock attributes include door_state, lock_state, secure_state and raw/decoded door status values. Startup status polling now populates DGP lock and contact information; live events keep it updated. Where no usable state is known, the entity can remain unknown.

The panel also distinguishes automatic lock modes, secure/unsecure, access grants, forced doors and doors open too long. Home Assistant exposes a practical subset; site-specific programming can affect how these states relate.

Relays

Relays appear as standard switches. Use them for equipment already connected to, and appropriately controlled by, the panel's outputs.

Live relay updates require output events on the dedicated communication path. If the state only changes after a reload or poll, check that filter first.

Door access events

Each configured door has an access event entity. Its event_type can be:

  • access_granted
  • access_granted_egress
  • access_denied — card rejection without an identified user
  • access_denied_void — explicit void denial with a user number when supplied
  • door_forced
  • door_open_too_long

The entity's state is a timestamp for the most recent event. Read the attributes for the event type, door and user details. Named access messages appear in Activity; History remains the event timestamp timeline.

Optional user name sync adds names to credential-based events. A panel-generated release may have no user, and an exit-button event does not necessarily identify a person. Last successful credentialed user information is retained so a denial or following system release does not erase who last gained access. Use last_user / last_user_name for that purpose; user / user_name describe the current event.

Scope and limitations

  • Object names are imported from export.panel, rather than downloaded directly from the panel. User names have their own download feature.
  • Timezone/schedule entities are not automatically imported from Tecom. A tile's schedule display uses an entity you supply.
  • Door modelling, especially forced/open-too-long presentation and site-specific logic, continues to be refined.
  • Direct area, input and door name downloads remain an area for future investigation.
  • Printer mode does not offer the structured state and control features listed above.

Clone this wiki locally