Repository navigation
Entities
← Documentation · Configuration · Events and actions
These features describe CTPlus / Management Software mode. Which entities appear depends on the configured object counts and ranges.
| Panel object | Home Assistant entity | Purpose |
|---|---|---|
| Area | alarm_control_panel |
Arm, stay arm, force arm, disarm and alarm status |
| Input / zone | binary_sensor |
Sealed or active state, with alarm information in attributes |
| DGP door | lock |
Lock, unlock and momentary release |
| Door contact | binary_sensor |
Physical open/closed state reported by the panel |
| RAS / keypad | Read-only lock/contact entities | Limited status; no door control |
| Relay / output | switch |
On/off control and status |
| Door activity | event |
Access grants, confirmed denials, egress and door exceptions |
| Last event | sensor |
Latest panel event and diagnostic attributes |
| Sync Users Now | button |
Download user names for the associated panel |
Each configured area has its own alarm control panel entity.
| Action | Behaviour |
|---|---|
| Arm away | Validated arming; the panel can refuse if inputs are unsealed |
| Arm home / stay | Stay-arms the area using the panel's programmed behaviour |
| Force arm | Arms regardless of unsealed inputs |
| Disarm | Disarms the area |
Force arm does not isolate unsealed inputs. An open input may immediately trigger an alarm. Home Assistant exposes this as alarm_arm_custom_bypass, but its behaviour here is the panel's force-arm command.
Changes made from a keypad, CTPlus or another panel client are reflected in Home Assistant when the corresponding events arrive. An area in alarm reports triggered; its alarm_inputs and alarm_input_names attributes identify the inputs reported in alarm.
Stay-armed areas report armed_home. The polled status word cannot distinguish stay from away, so an area already stay-armed before Home Assistant starts can initially show armed_away until an appropriate arm/disarm event is received. A known stay-arm state is preserved across subsequent polling.
- On means unsealed / active.
- Off means sealed / normal.
Inputs update from event traffic and status recalls. Motion detectors that do not send seal events need runtime input polling; a sensor's response speed then depends on the polling interval.
Alarm state is separate from seal state. The in_alarm attribute reports whether the input is in alarm; when applicable, alarm_area and alarm_area_name identify its area. Raw status attributes are available for troubleshooting. The status-bit interpretation is documented in the protocol reference.
A door's lock state and physical position are different. An unlocked door can still be closed, and a locked output does not prove the door has closed.
Use the lock entity for control and the Door Contact binary sensor for open/closed status. The contact indication depends on the panel's contact wiring and programming. The companion door tile can also use a separately selected reed/input sensor.
| Action | Result |
|---|---|
Open Door / lock.open
|
Momentary access grant using the panel's programmed release behaviour; does not change the latched lock mode |
Unlock / lock.unlock
|
Leaves the door unlocked until a later lock command or panel logic changes it |
Lock / lock.lock
|
Requests the locked mode |
DGP doors (17+) support these controls. RAS doors/keypads (1–16) are read-only because a RAS may be an arming station rather than a door controller. RAS status is a limited interpretation, not a substitute for a confirmed physical contact.
DGP lock attributes include door_state, lock_state, secure_state and raw/decoded door status values. Startup status polling now populates DGP lock and contact information; live events keep it updated. Where no usable state is known, the entity can remain unknown.
The panel also distinguishes automatic lock modes, secure/unsecure, access grants, forced doors and doors open too long. Home Assistant exposes a practical subset; site-specific programming can affect how these states relate.
Relays appear as standard switches. Use them for equipment already connected to, and appropriately controlled by, the panel's outputs.
Live relay updates require output events on the dedicated communication path. If the state only changes after a reload or poll, check that filter first.
Each configured door has an access event entity. Its event_type can be:
access_grantedaccess_granted_egress-
access_denied— card rejection without an identified user -
access_denied_void— explicit void denial with a user number when supplied door_forceddoor_open_too_long
The entity's state is a timestamp for the most recent event. Read the attributes for the event type, door and user details. Named access messages appear in Activity; History remains the event timestamp timeline.
Optional user name sync adds names to credential-based events. A panel-generated release may have no user, and an exit-button event does not necessarily identify a person. Last successful credentialed user information is retained so a denial or following system release does not erase who last gained access. Use last_user / last_user_name for that purpose; user / user_name describe the current event.
- Object names are imported from
export.panel, rather than downloaded directly from the panel. User names have their own download feature. - Timezone/schedule entities are not automatically imported from Tecom. A tile's schedule display uses an entity you supply.
- Door modelling, especially forced/open-too-long presentation and site-specific logic, continues to be refined.
- Direct area, input and door name downloads remain an area for future investigation.
- Printer mode does not offer the structured state and control features listed above.