Skip to content

v0.9.35 — PV/forced charge power register (reg 74)

Latest

Choose a tag to compare

@btli btli released this 05 Jun 22:25
· 6 commits to main since this release
8ca8ea2

Final release (promotes 0.9.35b7).

Fixed

  • Reg 74 (HOLD_FORCED_CHG_POWER_CMD) addressable on the local Modbus path — added to REGISTER_TO_PARAM_KEYS; was missing, which forced consumers onto the wrong register 64.
  • Reg 74 unit metadata corrected to 100W units (0-150 = 0-15 kW), same encoding as AC charge power (reg 66); fixed register comment, HoldingRegisterDefinition, scaling note, and HybridInverter.set_forced_charge_power()/get_charge_discharge_power() (now accepts 0-150). Hardware-verified: FlexBOSS reg74=20→2.0 kW, 18kPV reg74=120→12.0 kW.
  • Packaging — restored classifiers placement in pyproject.toml (uv build was broken).