Skip to content

Conversation

AlexJones0
Copy link

This is using the wrong mask and so is sending all four alerts on a SW-triggered fatal alert, but should actually just be sending the 1 alert designated for fatal SW alerts.

@AlexJones0 AlexJones0 changed the title ot_ibex_wrapper: Fix Fatal SW alert signal ot_ibex_wrapper: fix fatal SW alert signal Oct 13, 2025
This was using the wrong mask and so was sending all four alerts on a
SW-triggered fatal alert, but should actually just be sending the 1
alert for fatal SW alerts.

Also change the naming of the alert fields to more closely align with
the actual alert indexes, rather than being specific to the alert test
register.

Signed-off-by: Alex Jones <alex.jones@lowrisc.org>
@jwnrt jwnrt merged commit 22622fa into lowRISC:ot-9.2.0 Oct 14, 2025
9 checks passed
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.