Python package with reference library of serial commands (and responses) for PIP-4048MS inverters - aka:
- PIP-4048MS
- IPS-4000WM
- Voltronic Axpert MKS 5KVA Off-grid Inverter-Chargers
Good overview and technical discussion here http://forums.aeva.asn.au/viewtopic.php?f=31&t=4332
- a Raspberry Pi 3
- using 2x USB to serial adapters (like https://www.adafruit.com/product/18)
- to connect to 2x PIP-4048MS inverters connected in parallel
python ./setup.py install
$ mpp-solar -h
usage: mpp-solar-script.py [-h] [-c COMMAND]
[-ll {DEBUG,INFO,WARNING,ERROR,CRITICAL}]
[-d DEVICE] [-b BAUD] [-l] [-s] [-t] [-R]
MPP Solar Command Utility
optional arguments:
-h, --help show this help message and exit
-c COMMAND, --command COMMAND
Command to run
-ll {DEBUG,INFO,WARNING,ERROR,CRITICAL}, --loglevel {DEBUG,INFO,WARNING,ERROR,CRITICAL}
Set the logging level
-d DEVICE, --device DEVICE
Serial device to communicate with
-b BAUD, --baud BAUD Baud rate for serial communications
-l, --listknown List known commands
-s, --getStatus Get Inverter Status
-t, --getSettings Get Inverter Settings
-R, --showraw Display the raw results
$ mpp-solar -l
-------- List of known commands --------
PBT: Set Battery Type
PSDV: Set Battery Cut-off Voltage
Q1: Q1 query
QBOOT: DSP Has Bootstrap inquiry
QDI: Device Default Settings inquiry
QFLAG: Device Flag Status inquiry
QID: Device Serial Number inquiry
QMCHGCR: Max Charging Current Options inquiry
QMUCHGCR: Max Utility Charging Current Options inquiry
QOPM: Output Mode inquiry
QPGSn: Parallel Information inquiry
QPI: Device Protocol ID inquiry
QPIGS: Device General Status Parameters inquiry
QPIRI: Device Current Settings inquiry
QPIWS: Device warning status inquiry
QVFW: Main CPU firmware version inquiry
QVFW2: Secondary CPU firmware version inquiry
$ mpp-solar -s
================ Status ==================
Parameter Value Unit
ac_input_frequency 00.0 Hz
ac_input_voltage 000.0 V
ac_output_active_power 0152 W
ac_output_apparent_power 0207 VA
ac_output_frequency 50.0 Hz
ac_output_load 004 %
ac_output_voltage 230.2 V
allowscconflag 01
battery_capacity 100 %
battery_charging_current 018 A
battery_discharge_current 00000 A
battery_temperature 046 Deg_C
battery_voltage 57.40 V
battery_voltage_from_scc 57.45 V
bus_voltage 459 V
chargeaveragecurrent 00
fan_lock_status Not locked
fan_pwm_speed 0030 Percent
inverter_charge_status bulk stage
inverter_heat_sink_temperature 0057 Deg_C
inverter_temperature 034 Deg_C
pv_input_current_for_battery 0021 A
pv_input_voltage 069.9 V
scc_charge_power 1258 W
scc_flag SCC is powered and communicating
scc_pwm_temperature 051 Deg_C
sync_frequency 50.00
transformer_temperature 057 Deg_C