UPS Management
ZNAS integrates with Network UPS Tools (NUT) to monitor an attached UPS (Uninterruptible Power Supply) and automatically shut down the server when battery thresholds are reached.
The UPS feature is optional. It is installed from Requisites → Optional Features and does not affect the portal if not enabled.
Click Enable UPS Feature in Requisites → Optional Features to install NUT (Network UPS Tools). Once installed, the UPS battery widget appears in the portal's top bar.

- Go to Settings → UPS
- Click Scan for UPS devices
The portal scans USB and other interfaces and lists detected UPS devices.
In the UPS Settings panel:
| Field | Description |
|---|---|
| UPS name | Logical name for the UPS (e.g. myups) |
| Driver | NUT driver (e.g. usbhid-ups, apcsmart) — auto-detected from scan |
| Port | Device path (e.g. auto, /dev/ttyS0) — auto-detected |
| Description | Human-readable label |
Click Apply to write the NUT configuration files and start the NUT services.
Configure when the portal should shut down the server:
| Threshold | Description |
|---|---|
| Battery % | Shut down when battery drops below this percentage |
| Runtime remaining (s) | Shut down when estimated runtime drops below this value |
| Grace period (s) | Wait this many seconds after threshold is breached before issuing shutdown |
The most conservative threshold triggers first (whichever is reached first — battery % or runtime).
When NUT is running and a UPS is configured, a compact battery widget appears in the top bar showing:
- Battery percentage (color-coded: green / yellow / red)
- Charging / on battery / online indicator
- Load percentage
Click the widget to open the full UPS settings panel.
The full settings panel shows a visual battery gauge and a metrics grid:
| Metric | Description |
|---|---|
| Battery charge % | Current battery level |
| Battery runtime | Estimated time remaining |
| Input voltage | AC input voltage |
| Output voltage | AC output voltage |
| Load % | Current UPS load |
| UPS status | Online / On battery / Charging |
| Temperature | UPS temperature (if supported by driver) |
The portal monitors the UPS continuously. When thresholds are breached:
- The grace period countdown begins
- An alert is dispatched to all configured alert targets
- After the grace period, the server shuts down cleanly
Note: The shutdown requires either polkit permission for the
zfsnasservice account (standard on Ubuntu 22.04+) or adding the shutdown command to the sudoers whitelist. See Security for details.
Go to Settings → UPS → Uninstall. The portal stops the services, removes the NUT packages, and cleans up the configuration.
| Problem | Solution |
|---|---|
| UPS not detected | Try Full Scan instead of USB-only; check USB cable; run lsusb to verify USB visibility |
| NUT services fail to start | Check logs with sudo journalctl -u nut-server; verify the driver name and port |
| Battery widget not showing | Ensure NUT is running and the UPS is responding |
| Shutdown not triggered | Verify polkit or sudoers permission for the zfsnas user; check the shutdown threshold settings |
| Wrong battery percentage | Some UPS models require calibration; check the NUT driver documentation |
# List detected UPS devices (USB only, fast)
sudo nut-scanner -C -N
# Query UPS status (replace 'myups' with your UPS name)
upsc myups
# Check battery-related values
upsc myups | grep battery
# Check NUT service status
systemctl status nut-server nut-clientGetting Started