Getting Started
An original Awair Element contains:
- STM32F103VET6 sensor-board controller
- STM32F103RBT6 front-panel controller
- Glead ZYM-BI201 Bluetooth 4.0 module based on the TI CC2540
- MXCHIP EMW3165 Wi-Fi module containing the STM32F411 and Broadcom radio
- Telaire T6703, Sharp GP2Y10, FIS QS-01, and SHT30 sensors
- Macronix MX25L1606E 2 MiB SPI flash on the EMW3165 board
Rewair replaces firmware on the EMW3165. A CMSIS-DAP probe is required for the initial installation and for low-level recovery.
Wire a CMSIS-DAP probe, such as a Raspberry Pi Pico running picoprobe, to the test points on the opposite side of the EMW3165 module:
-
TP80/TP81: SWD, required for flashing and recovery -
TP103/TP104: debug UART, optional
Verify the pin direction and voltage before powering the target. The core workflow does not require the debug UART.
Version tags publish complete firmware bundles on the
Releases page. A bundle
contains the STM32 bootloader and application, the external-flash lookup table
and BCM43362A2 WLAN firmware, the SRAM SPI-flash loader, SHA-256 checksums, and
manifest.json.
The normal installation preserves DCT and saved configuration. The separate
rewair-default-dct.bin recovery asset erases saved configuration and includes
a build-generated MAC address. Never install one unchanged DCT image on
multiple devices.
For a source build and the exact flash commands, continue to Building and Flashing.
If no Wi-Fi credentials are saved, Rewair starts an open setup network named
rewair-setup-<xxxx>, where <xxxx> is derived from the final two bytes of
the Wi-Fi MAC address. Join it and open http://192.168.0.1/. The captive
portal should normally open automatically.
Select a network and save its credentials. Rewair stores the network and switches from access-point mode to station mode. Once joined, open the device's LAN address to use the same portal.
See Networking and MQTT for fallback behavior and Home Assistant setup.
If an experimental flash no longer boots, use the scripts and instructions in
tools/recovery
to restore the stock F411 firmware. Low-level SPI-flash details are covered in
SPI Flash and Recovery.