Skip to content

Temperature monitoring not showing for standalone node #536

@devachnid

Description

@devachnid

Describe the bug
Temperature monitoring is not showing in the dashboard for my standalone node

To Reproduce
Steps to reproduce the behavior:

  1. Configure temperature monitoring as per https://github.com/rcourtman/Pulse/blob/main/docs/TEMPERATURE_MONITORING.md
  2. Open Pulse UI - no temperatures being shown
Image

Expected behavior
Temperatures shown on dashboard

Environment:

  • Pulse Version: 4.22.0-rc.6
  • Installation Type: ProxmoxVE LXC

Additional context
journalctl -u pulse -f | grep -i temp = no output
journalctl -u pulse-backend -f | grep -i temp = no output
ssh root@192.168.1.200 "sensors -j" gives

{"coretemp-isa-0001":{"Adapter":"ISA adapter","Package id 1":{"temp1_input":50.000000,"temp1_max":85.000000,"temp1_crit":95.000000,"temp1_crit_alarm":0.000000},"Core 0":{"temp2_input":49.000000,"temp2_max":85.000000,"temp2_crit":95.000000,"temp2_crit_alarm":0.000000},"Core 1":{"temp3_input":48.000000,"temp3_max":85.000000,"temp3_crit":95.000000,"temp3_crit_alarm":0.000000},"Core 2":{"temp4_input":50.000000,"temp4_max":85.000000,"temp4_crit":95.000000,"temp4_crit_alarm":0.000000},"Core 3":{"temp5_input":46.000000,"temp5_max":85.000000,"temp5_crit":95.000000,"temp5_crit_alarm":0.000000},"Core 4":{"temp6_input":46.000000,"temp6_max":85.000000,"temp6_crit":95.000000,"temp6_crit_alarm":0.000000},"Core 8":{"temp10_input":44.000000,"temp10_max":85.000000,"temp10_crit":95.000000,"temp10_crit_alarm":0.000000},"Core 9":{"temp11_input":44.000000,"temp11_max":85.000000,"temp11_crit":95.000000,"temp11_crit_alarm":0.000000},"Core 10":{"temp12_input":49.000000,"temp12_max":85.000000,"temp12_crit":95.000000,"temp12_crit_alarm":0.000000},"Core 11":{"temp13_input":45.000000,"temp13_max":85.000000,"temp13_crit":95.000000,"temp13_crit_alarm":0.000000},"Core 12":{"temp14_input":45.000000,"temp14_max":85.000000,"temp14_crit":95.000000,"temp14_crit_alarm":0.000000}},"i350bb-pci-0103":{"Adapter":"PCI adapter","loc1":{"temp1_input":70.000000,"temp1_max":120.000000,"temp1_crit":110.000000}},"coretemp-isa-0000":{"Adapter":"ISA adapter","Package id 0":{"temp1_input":48.000000,"temp1_max":85.000000,"temp1_crit":95.000000,"temp1_crit_alarm":0.000000},"Core 0":{"temp2_input":46.000000,"temp2_max":85.000000,"temp2_crit":95.000000,"temp2_crit_alarm":0.000000},"Core 1":{"temp3_input":46.000000,"temp3_max":85.000000,"temp3_crit":95.000000,"temp3_crit_alarm":0.000000},"Core 2":{"temp4_input":42.000000,"temp4_max":85.000000,"temp4_crit":95.000000,"temp4_crit_alarm":0.000000},"Core 3":{"temp5_input":42.000000,"temp5_max":85.000000,"temp5_crit":95.000000,"temp5_crit_alarm":0.000000},"Core 4":{"temp6_input":41.000000,"temp6_max":85.000000,"temp6_crit":95.000000,"temp6_crit_alarm":0.000000},"Core 8":{"temp10_input":40.000000,"temp10_max":85.000000,"temp10_crit":95.000000,"temp10_crit_alarm":0.000000},"Core 9":{"temp11_input":42.000000,"temp11_max":85.000000,"temp11_crit":95.000000,"temp11_crit_alarm":0.000000},"Core 10":{"temp12_input":43.000000,"temp12_max":85.000000,"temp12_crit":95.000000,"temp12_crit_alarm":0.000000},"Core 11":{"temp13_input":45.000000,"temp13_max":85.000000,"temp13_crit":95.000000,"temp13_crit_alarm":0.000000},"Core 12":{"temp14_input":45.000000,"temp14_max":85.000000,"temp14_crit":95.000000,"temp14_crit_alarm":0.000000}}}

pulse-diagnostics-sanitized-2025-10-11.json

💡 Tip: If you're experiencing connection issues, API errors, or missing data, you can attach diagnostics from Settings → Diagnostics tab → Export for GitHub (sanitized version)