Background monitoring watches your drives while Diskoria is not in front of you. It wakes on a timer, reads each drive's health, records the temperature, and raises an alert if something crosses a line you set.

It is the difference between finding out a drive is failing and being told.

It runs for as long as the process is alive -- including when the window is closed to the tray. Closing the last window with "Close to system tray" switched off quits the process, and monitoring stops with it. See Tray and Flyout.

What it does on each cycle

Every poll, for every drive:

  1. Reads the drive's S.M.A.R.T.? or NVMe? health data.
  2. Stores a temperature reading in a local history database.
  3. Compares the readings against your thresholds.
  4. Raises a Windows notification and changes that drive's tray icon if a threshold has been crossed.

The default interval is 3 minutes, adjustable in Settings. It is on by default.

Internal drives are monitored; USB drives are opt-in. External drives come and go, so they are left out unless you turn on "Show USB drives in the tray" in Settings -- one switch that adds them to both the tray and the poll, since an icon with no reading behind it would be no use.

A sleeping drive is not woken to be measured. Before each reading Diskoria asks the drive whether it is spun down -- a question that does not itself spin it up -- and skips a drive that is. Without that, a reading every three minutes would keep an external disk turning indefinitely. The cost is a gap in the temperature history while the drive sleeps, which is the honest record: it was asleep, not at some assumed temperature.

What it checks

More than the three thresholds you can see in Settings. The full list:

Condition Fires when
Temperature warning Temperature reaches your warning threshold (default 60 degC)
Temperature critical Temperature reaches your critical threshold (default 70 degC)
NVMe critical warning The drive raises its own internal alarm flag
New reallocated sectors The reallocated count increases
New pending sectors The pending count increases
New uncorrectable sectors The uncorrectable count increases
Wear high Wear passes your threshold (default 90%)
Available spare low An NVMe drive's spare pool drops under its own threshold

The sector? conditions fire on an increase, not on a non-zero count. This matters. A drive that reallocated 24 sectors two years ago and has been stable ever since will not nag you every three minutes -- but the day it reallocates its twenty-fifth, you hear about it.

That is the right behaviour, and it is also why you should still look at Drive Health occasionally. Monitoring tells you about change. It will not tell you that a drive you just plugged in already has a bad history.

What an alert looks like

A Windows notification, titled with the drive and the severity:

Diskoria -- Drive Meridian ST2000-CX (Warning) Meridian ST2000-CX -- temperature reached 58 degC (threshold: 55 degC)

At the same time that drive's tray icon switches to its alert appearance, so the state persists after the notification disappears. See Tray and Flyout.

Cooldowns, so it does not nag

Each drive-and-condition pair has its own cooldown. Without one, a drive sitting one degree over the warning line would notify you on every single poll -- which is how people learn to ignore notifications.

Cooldowns are stored in the history database and survive a restart, so quitting and reopening Diskoria does not reset them and start the nagging again.

For a longer silence on one drive, right-click its tray icon and use "Ignore alert for:" -- 1 hour, 6 hours, 24 hours or 7 days.

Temperature history

Every poll appends a temperature reading, kept for up to 7 days. That is what fills the chart on Drive Health.

The consequence worth knowing: with monitoring off, that chart stays empty forever. It says

No history data yet -- collecting on next monitor cycle

which is accurate but easy to read as a fault. It is not: nothing is collecting because nothing is running.

Both the database and the settings live under %PROGRAMDATA%\Diskoria.

Testing it without waiting

Settings has a "Test notifications" row with Warning and Critical buttons. They raise a real alert for the first drive in your list, immediately.

Do this once, before you rely on any of it. Windows Focus Assist, Do Not Disturb, and per-app notification settings all silently swallow notifications, and you do not want to discover that from a drive that failed three weeks ago.

If something goes wrong

No notifications appear -- check Windows Settings > System > Notifications, confirm Diskoria is allowed, and check Focus Assist / Do Not Disturb. Use "Test notifications" to confirm rather than waiting for a real alert.

The temperature chart is empty -- monitoring is off, or has not completed a poll yet. Give it one interval.

A USB drive is not being monitored -- external drives are opt-in. Turn on "Show USB drives in the tray" in Settings. If it is already on and the drive still shows nothing, its bridge is one of the ones that will not forward health commands -- see Drive Health.

A gap in an external drive's temperature history -- expected. A drive that has spun down is left alone rather than woken for a reading, so the poll is skipped until it is back in use.

Monitoring stops when I close the window -- see Tray and Flyout for the close-to-tray rule.