82 changes: 82 additions & 0 deletions knowledge-base/scrollablepanel-prevent-scrollbars-moving.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,82 @@
---
title: Preventing Scrollbars from Moving When Clicking on the ScrollablePanel
description: Learn how to stop the automatic scrolling behavior of RadScrollablePanel to the focussed control inside.
type: how-to
page_title: How to Stop Scrollbars from Moving in RadDock for WinForms Windows
slug: scrollablepanel-prevent-scrollbars-moving
tags: panelsandlabels, scrollbar, auto-scroll, custom-class
res_type: kb
ticketid: 1663867
---

## Environment

|Product Version|Product|Author|
|----|----|----|
|2024.3.806|RadGridView for WinForms|[Dinko Krastev](https://www.telerik.com/blogs/author/dinko-krastev)|

## Description
When clicking on the content of the RadScrollablePanel, the scrollbars automatically move to make the focused control visible. This behavior is due to the `RadScrollablePanel` automatically scrolling to the active control. The goal is to disable this automatic scrolling behavior so that the scrollbars do not move when a window is clicked.

## Solution
To prevent the scrollbars from moving when clicking on a window, you need to override the `ScrollToControl` method of the `RadScrollablePanelContainer`. This involves creating a custom class that derives from `RadScrollablePanelContainer` and then using this custom container in your `RadScrollablePanel`.

First, create a custom `RadScrollablePanelContainer`:

````C#
public class MyRadScrollableContainer : RadScrollablePanelContainer
{
private RadScrollablePanel myParentPanel;

public MyRadScrollableContainer() : base(null)
{
}

public MyRadScrollableContainer(RadScrollablePanel parentPanel) : base(parentPanel)
{
this.DoubleBuffered = true;
this.SetStyle(ControlStyles.Selectable, true);
this.myParentPanel = parentPanel;
}

protected override Point ScrollToControl(Control activeControl)
{
Point result = Point.Empty;
if (myParentPanel != null)
{
result = new Point(-this.myParentPanel.HorizontalScrollbar.Value, -this.myParentPanel.VerticalScrollbar.Value);
}
return result;
}
}

````

Then, create a custom `RadScrollablePanel` that uses your custom container:

````C#
public class CustomRadScrollablePanel : RadScrollablePanel
{
protected override RadScrollablePanelContainer CreateScrollablePanelContainer()
{
return new MyRadScrollableContainer(this);
}

public override string ThemeClassName
{
get
{
return typeof(RadScrollablePanel).FullName;
}
}
}

````

Finally, replace the default `RadScrollablePanel` with your custom version in the applicable part of your application, such as the `OnWindowCreate()` method.

By implementing this custom container, you disable the default behavior that automatically scrolls to the active control, thus preventing the scrollbars from moving when a window is clicked.

## See Also
- [RadDock Overview](https://docs.telerik.com/devtools/winforms/controls/dock/overview)
- [Customizing RadScrollablePanel Behavior](https://docs.telerik.com/devtools/winforms/controls/panels/scrollable-panel/customizing-behavior)