136 changes: 108 additions & 28 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -5,28 +5,34 @@ Plugin for polling Modbus devices and publishing the data to thin-edge.io. If us

## Table of contents

- [Overview](#overview)
- [Requirements](#requirements)
- [Demo](#demo)
- [Config files](#config-files)
- [modbus.toml](#modbustoml)
- [devices.toml](#devicestoml)
- [Updating the config files](#updating-the-config-files)
- [Logs and systemd service](#logs-and-systemd-service)
- [Cumulocity Integration](#cumulocity-integration)

- [Installation via Software Management](#installation-via-software-management)
- [Log file access](#log-file-access)
- [Config management](#config-management)
- [Cloud Fieldbus](#cloud-fieldbus)
- [Writing operations](#writing-operations)

- [Testing](#testing)
- [Build](#build)
- [Debian package](#debian-package)
- [Deployment](#deployment)
- [As Python script (for dev only)](#as-python-script-for-dev-only)
- [As deb file](#as-deb-file)
- [tedge-modbus-plugin](#tedge-modbus-plugin)
- [Table of contents](#table-of-contents)
- [Overview](#overview)
- [Requirements](#requirements)
- [Demo](#demo)
- [Config files](#config-files)
- [modbus.toml](#modbustoml)
- [devices.toml](#devicestoml)
- [Updating the config files](#updating-the-config-files)
- [Logs and systemd service](#logs-and-systemd-service)
- [Cumulocity Integration](#cumulocity-integration)
- [Installation via Software Management](#installation-via-software-management)
- [Log file access](#log-file-access)
- [Config management](#config-management)
- [Cloud Fieldbus](#cloud-fieldbus)
- [Write operations](#write-operations)
- [thin-edge.io Commands](#thin-edgeio-commands)
- [Payload Formats](#payload-formats)
- [Write to Register (c8y\_SetRegister / modbus\_SetRegister)](#write-to-register-c8y_setregister--modbus_setregister)
- [Write to Coil (c8y\_SetCoil / modbus\_SetCoil)](#write-to-coil-c8y_setcoil--modbus_setcoil)
- [Testing](#testing)
- [Build](#build)
- [Debian package](#debian-package)
- [Deployment](#deployment)
- [As Python script (for dev only)](#as-python-script-for-dev-only)
- [As deb file](#as-deb-file)
- [Contributing](#contributing)
- [Coding Style](#coding-style)

## Overview

Expand Down Expand Up @@ -91,13 +97,17 @@ This includes the basic configuration for the plugin such as poll rate and the c
- connection to thin-edge.io (MQTT broker needs to match the one of tedge)
- log level (e.g. INFO, WARN, ERROR)
- measurement combination (opt-in feature to reduce the amount of created measurements in the cloud)
- subscribe_topics (MQTT topics for receiving write commands)

### devices.toml

This file includes the information for the connection(s) to the Modbus server(s) and how the Modbus Registers and Coils map to thin-edge’s Measurements, Events and Alarms. It's also possible to overwrite the measurement combination on a device level and on every single measurement mapping.

The device config can be managed via Cumulocity IoT or created with the Cloud Fieldbus operations.

Key configuration fields:
- `name` - Required for name-based write operations. Used to match metrics in write commands.

### Updating the config files

A watchdog observer will take care of restarting the MQTT and Modbus connection when either
Expand Down Expand Up @@ -172,11 +182,47 @@ For adding a modbus RTU device you need to use unit-ID of the slave device in th

### Write operations

The plugin supports writing to Modbus registers and coils through Cumulocity IoT operations.
The plugin supports writing to Modbus registers and coils through thin-edge.io commands (modbus_SetRegister/modbus_SetCoil) or Cumulocity IoT operations (c8y_SetRegister/c8y_SetCoil).

#### thin-edge.io Commands

The plugin subscribes to MQTT topics for receiving write commands:
- `te/device/+///cmd/modbus_SetRegister/+` - for writing to registers
- `te/device/+///cmd/modbus_SetCoil/+` - for writing to coils

These commands are processed directly by the modbus reader service. The Cumulocity operations (c8y_SetRegister/c8y_SetCoil) are converted to thin-edge.io commands via operation templates.

#### Payload Formats

The plugin supports two payload formats for write operations:

1. **Explicit address format** - directly specify register/coil address and parameters
2. **Name-based format** - use metrics array with name field to match configuration in devices.toml

For the name-based format, the `name` field in devices.toml registers/coils configuration is required to match the metrics. The matching uses prefix matching: if the metric name starts with the configured name, it will match. For example, a metric name `"foo_bar_setPoint"` will match a register with `name = "foo_bar"` in devices.toml.

**Command Status Flow:**
- Commands with `"status": "init"` are automatically converted to `"executing"` by the plugin
- The plugin processes the command and updates status to `"successful"` or `"failed"`
- The topic format must be: `te/device/<device-name>///cmd/modbus_SetRegister/<mapper-id>` where `<device-name>` must match a device name in devices.toml

Example name-based payload input for modbus plugin:
```json
{
"status": "init",
"metrics": [{
"name": "Test_Int16_xxxxxxxx",
"timestamp": "2025-09-23T01:00:00Z",
"value": 123
}]
}
```

#### Write to Register (c8y_SetRegister / modbus_SetRegister)

#### Write to Register (c8y_SetRegister)
Write values to Modbus registers. The plugin supports both integer and float register writes.

Write values to Modbus registers requires the following json to be included in the operation:
**Explicit Address Format:**

```json
{
Expand All @@ -192,6 +238,26 @@ Write values to Modbus registers requires the following json to be included in t
}
```


**Integer Register Writes:**
- For integer registers, the plugin performs a read-modify-write operation
- It first reads the current register value, applies bit masking based on `startBit` and `noBits`, then writes the updated value
- This ensures that only the specified bits are modified while preserving other bits in the register

**Float Register Writes (Name-based format only):**
- Float values are supported for registers configured with `datatype = "float"` in devices.toml
- Supported float sizes: 16-bit (half precision), 32-bit (single precision), 64-bit (double precision)
- The plugin automatically handles endianness conversion based on the device's `littlewordendian` setting
- Float writes require the name-based format and proper configuration in devices.toml

**Protocol Support:**
- TCP/IP Modbus: Specify `ipAddress` and ensure the device is reachable
- RTU Modbus: Device must be configured in devices.toml with serial port settings

**Error Handling:**
- If the Modbus device is offline or unreachable, the command will immediately fail with status `"failed"`
- No automatic retry mechanism is implemented; failed commands must be resent

To create an operation to write a value to a Modbus register using Cumulocity, you can use the [go-c8y-cli](https://goc8ycli.netlify.app/docs/cli/c8y/operations/c8y_operations_create/) tool:

```
Expand All @@ -205,10 +271,11 @@ In the Cumulocity UI, the widget '[Asset table](https://cumulocity.com/docs/cock
![Image](./doc/write-register-asset-table.png)


#### Write to Coil (c8y_SetCoil)
#### Write to Coil (c8y_SetCoil / modbus_SetCoil)

Write values to Modbus coils. Coils are single-bit outputs that can be set to 0 or 1.

Write values to Modbus coils requires the following json to be included in the operation:
:
**Explicit Address Format:**

```json
{
Expand All @@ -222,6 +289,19 @@ Write values to Modbus coils requires the following json to be included in the o
}
```

**Name-based Format:**
- Coils can be written using the name-based format with metrics array
- The coil `name` in devices.toml must match the metric name (using prefix matching)
- The metric value must be 0 or 1

**Protocol Support:**
- TCP/IP Modbus: Specify `ipAddress` and ensure the device is reachable
- RTU Modbus: Device must be configured in devices.toml with serial port settings

**Error Handling:**
- If the Modbus device is offline or unreachable, the command will immediately fail with status `"failed"`
- No automatic retry mechanism is implemented; failed commands must be resent

To create an operation to write a value to a Modbus coil using Cumulocity, you can use the [go-c8y-cli](https://goc8ycli.netlify.app/docs/cli/c8y/operations/c8y_operations_create/) tool:

```
Expand Down