Skip to content

Valve Sizing

stephanielue8088 edited this page Nov 26, 2023 · 13 revisions

SECTIONS

ASME Section VIII

Selection and Sizing of Pressure Relief Valves

How to Choose a Regulator

How to Perform Tube Fittings

How to Choose a Regulator

What is the purpose of a regulator

  • Help to main or control desired pressure and flow in response to system changes
  • Control upstream or downstream pressure in response to changes in the system
    • Changes include fluctuation in flow, pressure, temperature etc

What are the problems of not choosing the correct size of your regulator

  • Inefficiency
  • Poor Performance
  • Frequent troubleshooting
  • Potential Safety Hazards

How do pressure regulators differ from valves

  • Valves: Control system flow rates and do not self-adjust
  • Regulators: Control pressure, not flow, and are self-adjusting

Two Types of Regulators

  • Pressure Reducing

    • Sense outlet pressure
    • Control their own downstream pressure
  • Back - Pressure

    • Sense inlet pressure and control pressure from upstream

image

image


Important Characteristics to Consider: System Flow, System Pressure, System Temperature, Process Sensitivity and System Media

System Flow

  • Determine rate of flow in your system
  • Determine sizing of regulator components
    • (For ex.) Larger diaphragm or piston if better to control lower-pressure applications

System Pressure

  • Selection must be appropriately rates for (i) Maximum (ii) Minimum and (iii) Operating System Pressures

System Temperature

  • Joule - Thomson Effect can cause rapid cooling due to pressure drops
  • One must be confident that the choice in regulator can stand up to the typical expected operating conditions and environmental factors

Process Sensitivity

  • Sensitivity of your process plays a role in determining the best mode of control to choose in your regulators
  • Most regulators are either spring-loaded or dome-loaded
  • Spring Loaded
    • Controlled by operator turning an external knob
    • This controls the spring's force on the sensing element
  • Dome Loaded
    • Use fluid pressure from within the system to provide the set pressure on the sensing element

System Media

  • Understand material compatibility between all elements of your regulator and your system media

[Note!]: Your regulator supplier should be able to provide you with sizing information, pressure and flow requirements, temperature ranges, and the correct mode of control for your system needs.

Clone this wiki locally