Describe the bug
When deploying either VCF 9.0.0.0 or 9.0.1.0, the Cloud Builder run fails on the step "Validate NSX Install Image is Available," with the message of: "NSX install image validation failed for NSX Version - 9.0.2.0.25150386 Remediation: Please download NSX install image with Version - 9.0.2.0.25150386 Reference Token: XXXXXX "
Reproduction steps
- Download the VCF Installer and ESX files for 9.0.1.0
- Copy them to the 9.0.1.0 folder in the holorouter
- Run VCF deployment for 9.0.1.0
Expected behavior
VCF 9.0.1.0 Deployment to complete
Additional context
I tried the suggestion posted here: https://community.broadcom.com/vmware-cloud-foundation/discussion/holodeck-901-vcf-deployment-fails
- Download the VCF Installer and ESX files for 9.0.2.0
- Copy them to the 9.0.1.0 folder in the holorouter
- Update /holodeck-runtime/templates/bom.json to reflect the 9.0.2 file names
- Run VCF deployment for 9.0.1.0
I have confirmed that this workaround does solve the problem, and VCF 9.0.1.0 was able to deploy as expected.