How to work with OOS once it runs.

Controls

Front-panel keys and knobs work as labelled. The Menu button at the bottom left reaches every function. A channel key held for more than half a second, or a finger held on a channel's card, switches that channel between AC and DC coupling. A short press switches a channel that is off on and opens its menu. With several channels on, the first press on one that is not selected only selects it, so the knobs act on it (its card has the coloured border); the next press opens its menu, and a press with its menu open switches it off. A tap on a channel's card selects and opens the menu the same way; a tap with the menu open closes it.

Backlight

Display > Backlight sets the panel's brightness from 10 to 100 %, in steps that look even to the eye. It is a setting of the scope (/oos/system.conf).

Auto

Works on the channels that are on, at full bandwidth, and sets the memory depth back to Auto; each channel then gets its own bandwidth back. With no signal it restores the set-up. Afterwards a bar at the top of the plot offers a few periods, many periods, the rising edge or the falling edge of the trigger channel; its x or a tap elsewhere closes it.

Windows and full screen

Display > Windows splits the plot into two windows side by side, two stacked, or four. The same page puts each channel, math channel and the LA into a window; a new split spreads the channels that are on. All windows share the time base, and a drag in a window moves a channel of that window. Zoom, XY and the analysers use one window. The button with four corners at the top right of the plot gives the plot the whole screen; it shows inward corners then and brings the top bar and the cards back. The box button under it arms one drag: the next drag on the plot draws a box, and that box is the zoom window. A tap does not zoom.

Views

Instead of one screen with everything on it, Display > Views (2, 3 or 4) gives screens to switch between. Each view keeps what is shown and where: the windows, the second pane, the measurements and their bar, DVM and counter, the cursors, the zoom, the histogram, the analyser page, XY and full screen. The channels, the time base, the trigger and the acquisition are the same in all of them; what changes while a view is shown stays with it, and a view not used yet starts with the plot alone. To switch: the numbers left of the top bar's buttons, a swipe from the left or right edge of the plot inwards (a vertical drag there still moves a channel or the trigger level), the Quick key set to Next view, or SCPI :DISPlay:VIEW <n> (:DISPlay:VIEW:COUNt <1..4>). The views are saved with a setup.

Text size

Display > Text size makes the text larger: Normal is the original look, Large and Larger use fonts 2 and 4 pixels bigger in the top bar, the cards, the measurement and cursor rows, the menus, the keyboard and the dialogs. The rows under the plot grow with them, so the plot gets a little shorter. Where a long text would not fit (a narrow channel card with four channels on, a long button label in the start menu, a narrow table column) it stays at the next smaller size, and the dense figure tables of the eye / jitter view keep the normal size. The setting is kept with the other preferences and across restarts; Default set-up and Recall keep it.

Bandwidth and noisy signals

A channel's bandwidth is Auto by default: the limit follows the sample rate, as on the stock system. With Full, the noise of a slow signal can be larger than the trigger hysteresis and the hardware triggers on the other edge too; the display still shows the edge you set, and Trigger > Noise reject widens the hysteresis.

Keyboard

Names, formulas and WLAN passwords are typed on the on-screen keyboard. The arrows either side of Space move the insertion point, a tap into the entry puts it there; typing and Delete work at that point.

Generator

Tap the frequency in the generator window for a keypad with units; the limits apply by themselves. The - and

  • buttons step it. Changes inside one amplitude range take effect at once and keep the output running.

Analysers

Menu > Analysers holds Spectrum, Eye / jitter, Power analysis, Bode and the bandwidth test. Eye/Jitter opens as a full analysis page with optional side or lower panes and has source/rate settings and Close in its pane header. Other analyser views use the button with three dots at the top right for Exit and Settings.

Bode with an external generator

In Analysers > Bode pick the Generator preset (Rigol DG, Siglent SDG, UNI-T UTG900 for the UTG932 and UTG962, or SCPI for one that takes FREQ and VOLT), then Connection: LAN with Gen address (IP, port 5555 if none is given; the knob moves the last number) or USB for a generator in the USB-A port of the scope. On USB the scope takes the first USBTMC instrument it finds (no PC, no driver), asks it for *IDN? and shows the answer; without one the sweep stops with the reason (no USB device, a device that is not USBTMC, no permission). Rigol DG and Siglent SDG generators are USBTMC instruments as well. The scope sets channel 1 of the generator to a sine of Amplitude (Vpp) without offset, switches its output on and steps through the frequencies. Over SCPI, :BODE:GENerator "usb" selects USB and :BODE:GENerator "192.0.2.20:5025" the LAN again.

  • UNI-T UTG900 commands: :CHANnel1:MODe CONTINUE, :CHANnel1:BASE:WAVe SINe, :CHANnel1:AMPLitude:UNIT VPP, :CHANnel1:BASE:AMPLitude, :CHANnel1:BASE:OFFSet 0, :CHANnel1:BASE:FREQuency, :CHANnel1:OUTPut ON, from the UNI-T UTG900 series programming manual (REV 00, 2022-07-15; the English UTG900E manual has the same commands). Not yet tried with a real UTG900.

Bode with a free-running sweep

For a generator that the scope does not control, but that sweeps on its own and gives a sync (marker) pulse at the start of each sweep. Wire the generator to the input of the device under test and to the input channel (CH1), the output of the device to the output channel (CH2), and the sync output to CH4. In Analysers > Bode set Generator = Free-running sweep, then the same Start freq, Stop freq, Sweep time and Sweep (Lin or Log) as on the generator, the Sync channel, its edge and level (the sync pulse must cross the level; set the channel's scale so the pulse is on the screen). Input (ref) Off compares the output with Ref level in dBV (0 dBV = 1 V RMS) instead of an input channel. Points is the number of frequencies read from the sweep. Start / stop sweep sets the time base and the memory for one sweep, triggers once (SINGLE) on the sync edge and waits; start the sweep on the generator. The plot shows the gain over frequency, the settings come back afterwards.

  • Each frequency is read in a short window of the record, about 4 periods long and never wider than 25 % in frequency, by a fit of a sine that follows the sweep. Where the sweep passes a frequency in less than one period, that frequency is left out (the message says so). Over three decades, 20 Hz needs a sweep time of a few seconds; a linear sweep needs much more time for its low end than a logarithmic one.
  • Phase comes from the fit of both channels and is shown only with an input channel, where both fits are clean.
  • Sweeps up to about 0.9 s run as normal records (100 ms/div at most), the trigger one division from the left edge. Longer sweeps run in scan mode (Auto Roll off during the sweep, up to 200 s/div, 500 s and more): the trigger sits at the centre, the sweep in the right half, and the record holds min/max pairs. There the gain is half the peak-to-peak value in each window, and there is no phase. The start of the sweep is taken from the sync edge in the record itself.
  • On a 2-channel model use CH1 for the output, CH2 for the sync and Input (ref) Off.
  • :BODE:RUN ON starts it over SCPI, :BODE:DATA? returns the points (phase NaN where there is none).

Panes

Display > Pane puts a second view under the waveform: Spectrum with a peak list, Results with statistics, cursors and peaks, decoder Events, or Trend with two charts. Tap the pane's title for its settings, a trend chart to change its measurement, the peak list's button to sort it. The x closes the pane.

Measurements

A default set-up shows six in the strip under the plot. Measure > Dock moves that strip to the left, the right, or above the trace. In Measure > Add item a tap adds a measurement of the source channel and a second tap removes it. Measure > Labels on trace draws level lines and arrows with their values on the waveform.

Overclocking

System > Overclock sets the sample clock from the next power-on. Above 1.25 GHz the noise rises, and 2 GHz gives wrong samples: it is for tests only. See docs/models.md.

Web remote

Open http://<scope>:8080/. Click on the picture to touch the screen, drag to swipe. It scales with the window, so it also works on a phone. The buttons at the bottom save a screenshot or the last record to your computer; records above 2 million points have to be saved on the scope or read over SCPI. The live picture is a PNG of about 90 KB; "Live picture format" can switch it to the uncompressed 1.8 MB BMP, or to a JPEG of about 75 KB that the scope's video encoder makes at under a third of the processor time of a PNG (text a little less sharp; screenshots stay PNG). The choice is kept in the browser. The PNG is made off the scope's frame loop, only of a changed screen, up to 20 a second (about 13 reach a browser over Ethernet); the page gets each new picture as soon as it is made, and while the screen stands still it gets "not modified" instead. The scope's own screen does not slow down for it. Pause stops the pictures, and a tab in the background stops them too. The Update link leads to the update page.

Files

Setups are kept on OOS's own persistent area /oos and survive a power cycle. Screenshots and CSV files go to a USB stick in the front port (FAT32, exFAT or ext4), into the folder OOS, and can be pulled whenever nothing is being saved. Without a stick they go to /tmp/oos, which is in RAM and lost at power-off, unless you set another directory with --store-dir. The web remote saves them to your computer too. /oos holds 16 MiB for calibration and settings.

Self-calibration

System > Self-cal. Let the scope warm up for 30 minutes and disconnect all inputs first. It takes about 5 minutes per channel and pass, with 4 passes. Results go to /oos/cal and are preferred over the factory files, which are never changed.

Updates

Take oos-<version>.oosupd from the latest release, or build a package yourself (target/image/oos-dev.oosupd), then install it on the running scope:

curl --max-time 300 --data-binary @oos-<version>.oosupd http://<scope>:8080/update

or open http://<scope>:8080/update in a browser. The scope restarts into the new build by kexec before anything is written, and the new build installs itself from there; if its kernel hangs, a power-cycle starts the previous build again. After the install, power-cycle: that start is the trial (coming from 0.1.0, which has no kexec start, too). From 0.1.6 or older go to 0.1.7 first: 0.1.8 and later bring another device tree (the GPU and the video encoder on), and only 0.1.7 and later start such an image by kexec with its own tree; 0.1.6 refuses it. The new build runs on trial. If it crashes in a loop or never becomes stable, the previous image is written back. System > Update shows the state and System > Roll back update returns to the previous image. Details: docs/update.md.

Network

Tap the network box at the top right: it shows the addresses of Ethernet and WLAN and the address of the web remote. For WLAN, put an RTL8188EU stick into the front USB port, tap Find WLAN networks, tap a network and enter the password. It joins by itself from then on. Everything open on Ethernet is then open on that network too. Details: docs/wlan.md. The page also shows the speed of the Ethernet link; a link at 10 Mbit/s gets one more autonegotiation (10 Mbit retry, on by default, docs/network.md).

Date and time

The scope has no clock battery and starts in 2013. System > Date and time > Time from NTP (off by default) sets the clock from pool.ntp.org or another server whenever a network link comes up, and every hour; Time zone picks the zone with its daylight saving rules (or takes a POSIX TZ string), Set the clock takes it by hand. From then on file names carry the local date and time (shot-20261111-143005.png) instead of a number. The settings are in /oos/system.conf, see docs/network.md.

Waveform files

Storage saves CSV and a compact binary file wave-NNN.bin (wave-<date>-<time>.bin once the clock is set), little endian: OOSW, u32 version (1), u32 channels, u64 samples per channel, f64 dt, f64 t0, then per channel its number (u32) and the samples (f32, volts). Both hold the record on the screen.

Experimental limits

/oos/limits.conf overrides limits for your own tests. Every applied value is shown at start and in the System info. See the disclaimer and docs/models.md.