v0.9.2

  • Feature: Battery First / Grid First SOC limit controls on MIN TL-XH (PR #311): Two new number controls confirmed against V1.39: batt_first_charge_stopped_soc (H3048, 0–100%) stops charging at a set SOC in Battery First mode; grid_first_discharge_stopped_soc (H3067, 1–100%) stops discharging at a set SOC in Grid First mode (V1.39: US model / firmware ZACA-08+). batt_first_charge_power_rate (H3047) is now also available on TL-XH (was MOD/MID only). All appear as sliders under the Battery device.

  • Feature: Grid Connection Status sensor (PR #311): New text sensor on hybrid profiles with VPP equipment status (SPH, SPM, MOD, MIN TL-XH, WIT, SPA, SPE, MID V2.01). Reports On-grid / Off-grid / Unknown / Offline under the Grid device.