# Midea Heat Pump Water Heater v0.1.0
Midea Heat Pump Water Heater v0.1.0
Major architectural upgrade - Direct Modbus integration eliminates external dependencies.
What's New in v0.1.0
Built-in Modbus Client
- Self-contained integration - No longer requires external modbus.yaml configuration
- Direct register communication - Built-in pymodbus client handles all Modbus operations
- Simplified setup - Single configuration block in configuration.yaml
- Better connection handling - Automatic reconnection and error recovery
- Configurable polling - User-defined scan intervals
Enhanced Configuration
- Friendly name support - Customize entity display names
- Direct register addressing - Configure temp, mode, power, and target registers
- Temperature scaling options - Built-in offset and scale parameters
- Flexible temperature limits - User-defined min/max values
Breaking Changes from v0.0.2
Configuration Migration Required:
Old Configuration (v0.0.2):
# Required separate modbus.yaml file
modbus: !include modbus.yaml
midea_heatpump_hws:
water_heatpump:
heater_switch: switch.water_heatpump_on_off_toggle
mode_sensor: sensor.water_heatpump_mode
temperature_sensor: sensor.water_heatpump_temperature_bottom_of_tank_T5L
# ... additional configNew Configuration (v0.1.0):
midea_heatpump_hws:
water_heatpump:
friendly_name: "Hot Water System"
modbus_host: 192.168.1.80
modbus_port: 502
modbus_unit: 1
scan_interval: 30
temp_register: 102
target_temp_register: 2
mode_register: 1
power_register: 0
temp_offset: -15
temp_scale: 0.5
target_temperature: 65
min_temp: 40
max_temp: 75Migration Steps
- Remove external modbus configuration - Delete modbus sensors and switches from modbus.yaml
- Update configuration.yaml - Replace entity references with direct modbus parameters
- Remove modbus include - No longer need
modbus: !include modbus.yaml
Technical Improvements
Modbus Communication
- AsyncModbusTcpClient - Uses modern async modbus client
- Robust error handling - Graceful connection failure recovery
- Optimized polling - Batch register reads in single operations
- Connection management - Automatic connect/disconnect handling
Register Support
- Temperature monitoring - Register 102 with offset/scale support
- Target temperature control - Register 2 for setpoint writes
- Operation mode control - Register 1 (values: 1=Eco, 2=Performance, 4=Electric)
- Power state control - Register 0 for on/off operations
Dependencies
- pymodbus>=3.0.0 - Added for direct modbus communication
- Home Assistant 2024.1+ - Required for modern water_heater features
Known Issues
- Single device limitation - Currently supports one heat pump per installation
- Manual configuration - No UI config flow (YAML only)
- Network dependency - Requires stable connection to RS485 adapter
What's Next
Planned for v0.2.0:
- Configuration UI (eliminate YAML editing)
- Enhanced diagnostics (connection status monitoring)
- Multi-device support
- Energy monitoring capabilities
Full documentation: [README.md](https://github.com/0xAHA/Midea-Heat-Pump-HA/blob/main/README.md)