Added
A logbook entry for the case in which surplus is actually lost: the inverter curtails once the
feed-in passes the peak-shaving threshold and it can no longer route the current into the
battery. That is the counter-condition to the peak-shaving branch, which does not start on a
full battery, so until now the one situation that costs yield was the only one not reported.
The debounced export trigger reports it once per crossing, the half-hour run keeps a lasting
curtailment visible.
Changed
The charge-current simulation halves the search interval instead of stepping through it in
1 A increments. The simulated capacity is monotonic in the current, so bisection returns the
same value in a fixed number of rounds. The stepping scan ran up to the configured maximum
whenever the demand could not be covered in the window at all, which is the most common case
and the one where the result is only a fallback.
The optional parts of the helper package ship commented out instead of asking to delete them.
Home Assistant validates each group as a whole, so one forgotten placeholder in the wallbox or
backup-circuit blocks dropped the mandatory half-hourly house meter with it, and the error then
pointed at an unassigned field rather than at its cause.
Traces are kept for 800 runs instead of 400, so a diagnosis still finds the day before last.
The diagnostic recording is set up outside the web root. Everything under /config/www is
served at /local without any authentication, and the recording describes the site in detail.
The setup releases one directory through allowlist_external_dirs and names Samba, the file
editor or scp as the way to fetch the file.
The weather recording keys each source by its integration instead of its entity id. Entity names
carry the site location on some integrations, and only the source matters for comparing forecast
error; one entity per integration keeps the mapping unambiguous. Without a registry entry the
position in the selection is used, never the entity id.
The note appended to the peak-shaving message when no morning blockade ran is marked as
informative instead of a misjudgement of the forecast. Shaving a peak is what the branch is for,
and it costs nothing while the battery still takes charge; the new curtailment entry reports the
case that does.
Removed
The calendar guard that suppressed the morning blockade from November to February, together
with the snow detection that hung off it. The detection could never fire, because its own
condition required one of those months while the blockade excluded them in the same chain.
What the guard was for is answered more precisely elsewhere: the blockade only starts when the
forecast expects an export peak worth shaving, and the reality check pulls the available
surplus down to what the panels actually produce, so covered panels keep it from starting.
Fixed
Two field descriptions offered a shadow BMS as supplied although the package states it is not
included, and the description of the battery power sensor did not name the sign convention the
export and discharge detection depend on.
The blueprint description named the state before the discharge planning existed. It now says
what the automation does today, which is the first text Home Assistant shows in the list.
The description of the first time-of-use field promised a nightly recharge from the grid. That
behaviour went away when the discharge planning took over the registers. The field now states
what it does and names the inverter operation mode the value needs to take effect.
Three comments claimed a 30 s debounce for the two export triggers where the code has two
minutes for both. The reason for the equal debounce is now written once, at the trigger it
belongs to, instead of being restated in contradictory form at three places.
The optimizer request in the package waited up to two minutes. The run sits in the same queue
as monitoring and peak shaving, so a hanging optimizer delayed control; it now gives up after
twenty seconds, which is ample for a local service and diagnosis only anyway.