V6.13.0

Choose a tag to compare

@github-actions github-actions released this 20 Sep 12:58
d667cf0

Added

  • An optional second state-of-charge sensor. Where a more accurate BMS measures the same
    battery, the whole cascade now computes in its scale, and the difference to the inverter's
    own reading is applied at the register boundary only: added when the discharge floor is
    written, subtracted when it is read back. The inverter enforces its ToU registers against
    its own BMS, so a floor derived from the accurate reading was enforced at the wrong state
    of charge. Without the sensor the difference is zero and nothing changes.
  • A logbook message when the second reading is unusable and control falls back to the
    inverter's own value. Nothing about the behaviour shows that fallback, and a reading taken
    as zero would pull the floor to the bottom.

Changed

  • The state-of-charge field is now explicitly the value the inverter itself sees; the more
    accurate sensor belongs in the new field. Instances that followed the earlier hint and put
    a shadow sensor in the old field have to swap the two before the new one takes effect.
  • The inverter's shutdown state of charge is converted into the control scale before the
    backup reserve builds on it, because that reserve is what holds in an outage.
  • Without discharge planning the ToU minimum is written converted as well, so the configured
    percentage means the same state of charge everywhere it is used.
  • The balancing voltage stays as an input, now only as the threshold at which the measured pack
    voltage counts as full while every BMS is offline — the fallback that starts a balancing run
    when no cell voltages are readable. It is named and described for that role; value and effect
    are unchanged.

Removed

  • The blueprint no longer writes any voltage to the inverter. Raising the float voltage for a
    cell-balancing run, setting it back when the cooldown timer expires and the midnight check that
    caught a voltage left raised by a lost timer are gone, together with the two float-voltage
    inputs and the timer triggers that existed only to drive them. Writing a setpoint the charger
    already manages means owning its failure modes for no gain: cell balancing works through the
    throttled charge current alone.