Smart Home Control 26.9.1

Fixed

  • The device menu no longer opens twice. The menu is modal, but a global
    NVDA gesture reaches the add-on anyway, so pressing the shortcut again built
    a second dialog on top of the first. Two of them are not only confusing to
    listen to: the second one took over the reference the live update hangs on
    and cleared it when it closed, so the dialog left standing silently stopped
    being updated. The shortcut now brings the open menu to the front.

Changed

  • Credentials are no longer kept in NVDA's configuration. NVDA writes the
    complete configuration into the log when it starts, so everything stored
    there travels with every log a user sends in - the email address in plain
    text. Email addresses, passwords and tokens now live in a file of their own
    beside the add-on, which the log never sees. What is stored has not changed:
    passwords and tokens stay encrypted and readable only on the machine and
    user account they were saved on. Existing credentials move by themselves on
    the first start; if that file cannot be written, they stay where they were
    rather than being lost.
  • The checks are part of the repository now and run in the build workflow.
    Ten scripts that assert what has already broken in this add-on once - a
    translation without context, a lamp that remembered its colour mode, a
    sensor dropout, a tree that lost its selection. They used to live on one
    disk and only ran when someone remembered them.
  • The readme says how to translate the add-on: where the template is,
    what a .po file needs, and that the manual is optional.

Installation

  1. Download the .nvda-addon file below
  2. Open the file with NVDA
  3. Confirm the installation
  4. Restart NVDA

See the README for setup instructions per platform.

v26.8.2

Choose a tag to compare

@github-actions github-actions released this 30 Aug 14:59

Smart Home Control 26.8.2

Cosori air fryers

The CAF-P583S series (Dual Blaze) is supported, in any country variant.

  • What it shows: the cooking state, the loaded programme, the remaining
    time and both temperatures - the measured one and the one the programme was
    set to, in the unit the appliance reports. The measured value is damped, so
    the line is not re-read every fifteen seconds without saying anything new,
    and it is left out in standby where the appliance stops measuring.
  • Start a programme with the appliance's own temperature and time or with
    values chosen here, change the cooking time while it runs, and stop
    it
    - each after a prompt. The temperature cannot be changed during a cook;
    the appliance does not accept one then, and a line in the tree says where it
    can be set instead.
  • The programme list is learned, not written down. Every programme loaded
    on the appliance is noted and can be started by name from then on. Merely
    selecting one there is enough.
  • The end of a programme is announced, as are one starting to run and one
    being paused - with the device menu open or closed. One switch under
    Notifications turns all three off.
  • Starting may not mean heating: Cosori state that their air fryers cannot be
    switched on remotely. The confirmation therefore says "set", and the
    programme state says within one poll whether the appliance began by itself
    or is waiting for its own start button.

Fixed

  • A lamp remembered its colour mode for good. A mode set from the add-on
    was cached and outranked the lamp itself indefinitely, so an MSL450 put into
    white mode at the lamp or in the Meross app went on being shown in colour
    mode. The cache now expires after a minute.
  • A sensor dropout is no longer announced or recorded. A Levoit purifier
    reports -1 for its particulate sensor when it has no reading. That reached
    the interface as a measurement and the history as a data point; now the last
    good reading stays on the line and nothing is recorded.
  • Ctrl+B in the favorites tab removed the whole power strip when it was
    standing on a single outlet.
  • The favorites layer now requires the switching press to follow the
    announcement within a few seconds, adjustable in the settings. A digit
    pressed by accident much later announces the status again instead of
    switching.
  • The selected line no longer moves by itself when the tree is refreshed
    mid-programme, and a line is no longer announced twice.
  • The connection test announced its result twice, once as the status line
    and once as a message with the same content.
  • The selection survives a refresh. Every rebuild of the device tree put
    it back on the first entry: whoever stood at the fifth device started over
    at the top. The entry is found again by its identity - not by its label,
    which carries the values - and a line that has disappeared in the meantime
    falls back to its device.
  • A refresh is announced once, not two or three times. It rebuilt the
    whole tree even when only values had changed, and deleting and re-adding
    the entries reported a selection each time, with the focus that followed
    reporting it once more. The structure is now compared first; an unchanged
    list is only written into.
  • A platform switched off in the settings leaves the tree. Its polling
    stopped at once, but its devices stayed - offered for switching, answering
    nothing - until NVDA was restarted.
  • A VeSync account holding only unsupported devices reported "no devices",
    which reads exactly like a refused sign-in. The types are now named in the
    log and the account is reported as connected.

Changed

  • Credentials are proven at the platform before they are saved, and they
    reach a session that is already running - a wrong password used to be
    accepted silently and surfaced only at the next NVDA start. A refused
    sign-in offers to enter them again, at the tab concerned. Two parallel
    sign-ins of the same platform can no longer happen.
  • The add-on writes its version into the log, so a test report can be
    tied to the build that produced it.
  • Every text now carries a note for translators, saying what it is and
    where it stands - a button, a status line, or one of the line beginnings
    the device tree and the F1 help have to agree on word for word. 365 of them
    had none, and the build now refuses a text without one.
  • The three texts the add-on store shows - the name, the description and
    "What's new" - are translated through the catalogue as well, the way the
    official add-on template does it. The localised manifests in the package
    are generated from it, so a further language needs nothing but its .po
    file. "What's new" is markdown now: NVDA renders it and reads it line by
    line.
  • A refused command records the cloud's answer and the payload that was
    sent, instead of only the message shown to the user.
  • The manual claimed the add-on logs neither passwords nor tokens nor the
    email address. True of the add-on - but NVDA writes the whole configuration
    into the log at startup, and the email address stands there in plain text.

Installation

  1. Download the .nvda-addon file below
  2. Open the file with NVDA
  3. Confirm the installation
  4. Restart NVDA

See the README for setup instructions per platform.

v26.8.1beta1

v26.8.1beta1 Pre-release
Pre-release

Choose a tag to compare

@github-actions github-actions released this 17 Aug 19:45

Smart Home Control 26.8.1beta1

Initial pre-release, for testing. What the add-on does:

  • Four platforms, each usable on its own. Meross (plugs, power strips,
    lights, LED strips, diffusers, hubs with temperature, humidity and water
    sensors), Netatmo (thermostats and valves, weather station and indoor air as
    a display), VeSync / Levoit (air purifiers and tower fans) and Cozytouch /
    Atlantic (hot water heat pump, experimental – one device model tested so
    far).
  • One tree view for everything. NVDA+Shift+H opens it: arrow keys to
    navigate, Enter to switch, speech and tone feedback for every action.
  • A favorites layer. Devices used often – down to a single outlet of a
    power strip – get a digit and are switched with two keystrokes, without
    opening the menu. One assignable shortcut, not eighteen separate gestures.
  • Changes made elsewhere are announced, whether they came from the
    manufacturer app, a voice assistant or the button on the device itself.
  • A history of switching actions and sensor readings, with a detail view
    that can be read line by line and a CSV export. Dates, times and separators
    follow the system region, and the timestamp survives a spreadsheet intact.
  • Sign-in once, with the manufacturer account. New credentials are proven
    at the platform before they are stored, so a typo is caught while it can
    still be corrected. Storage is encrypted and local (Windows DPAPI).
  • Careful with the cloud budget. Meross allows 200 messages per hour and
    device; background polling keeps a reserve that only user-initiated queries
    may spend.
  • English and German. The source language is English, so an interface
    without a matching translation stays English rather than becoming German.
    Another language is a matter of one .po file.

Known in this pre-release

  • After a refresh, and after a platform is connected late, the selected entry
    in the device tree is announced two or three times, once with the wrong
    level; the NVDA log notes an error in its tree handling. The cause is the
    tree being rebuilt while it holds the focus. Nothing is lost, and switching
    devices is unaffected.
  • The same rebuild puts the selection back on the first entry – a position
    further down the list is not kept across a refresh.
  • Switching a platform off in the settings stops the polling immediately, but
    its devices stay in the tree until NVDA is restarted.

Installation

  1. Download the .nvda-addon file below
  2. Open the file with NVDA
  3. Confirm the installation
  4. Restart NVDA