Version 0.1.0 is the first stable release of the SEM Analysis Pipeline.
Archived software DOI: https://doi.org/10.5281/zenodo.21845096
The released capability is paired-acquisition external-aggregate projected
aspect ratio. It uses automatic multiscale silhouette segmentation, explicit
abstention, and paired physical-mask IoU quality control. It does not measure
isolated-crystal morphology or three-dimensional sphericity.
Verification
- All 27 repository tests pass on macOS and Ubuntu with Python 3.11, 3.12, and
3.13. - A clean 64-image rerun reproduced all 32 manuscript field dispositions, all
16 accepted primary and secondary aspect ratios, and all 22 available
paired-mask IoUs exactly. - The blinded real-envelope synthetic challenge accepted 33 of 60 images, with
minimum accepted-mask IoU 0.9566 and maximum absolute aspect-ratio error
2.69%. - All eight complete accepted synthetic pairs passed paired-mask QC, with
maximum cross-acquisition aspect-ratio difference 1.56%. - An independent public-only audit regenerated the challenge corpus, reran the
tagged candidate package, and reproduced the published synthetic results.
A separate Claude Code audit independently reproduced the released
single-image score report byte-for-byte.
Frozen validation assets
sem_paired_real_envelope_validation_frozen.zip:
7ea6207e8f622917202a7565d6a09ae8d6a42d27822b26636e0f3749073a3541sem_real_envelope_predictions_frozen.zip:
0ac1166024c34826f88b40d98ae7f24d27da5d4f74fe131fe2175643844c423esem_real_envelope_scores_single.json:
154e3552eff82db1720167f0d9686cc6f0949620e757ca18b5ba57e3b21a2758sem_real_envelope_scores_paired.json:
21d6ed9869d14621aaef1fadb8f0dee09a0aa914fac03af0340ed76cc36ebf9e
Regenerating the private manifest in an independent environment changed nine
harmonic-amplitude decimal serializations by at most 6.94e-18; all 60
rendered images and all 60 truth masks remained byte-identical.
Synthetic validation is limited to one isolated, fully visible, bright,
star-convex aggregate within the documented acquisition envelope. It is not
experimental ground truth for touching, truncated, charging-affected, or
otherwise unmodeled SEM fields. The public manuscript-reference tables are
internally consistent, but the 64-image experimental segmentation cannot be
independently rerun from this software release because the source images and
exact experimental run manifests are handled in a separate research-data
deposit.