OADM 2.5.0
Added
-
Live View page: saved views of several cameras at once, opened in tabs. Create a view, drag cameras from the list
into it, move and resize them on a grid, and save it for every user. Up to 16 cameras per view; "Change views" in the
roles decides who may create and change views. -
Live view: zoom and focus for cameras with a remote zoom or focus lens, in a bar over the picture: Zoom and Focus
sliders, Autofocus, Autofocus area (drag a frame over the picture) and Reset focus. Needs the new
permission Optics Control (Operator has it). -
Live view: PTZ cameras move by dragging from the circle in the middle of the picture, zoom with the mouse wheel,
center on a click, and go to Home or a preset from the bar. -
RTSP port per camera: right-click a camera, OADM > RTSP port, for cameras behind a port forward such as the
AXIS Virtual Loan Tool. The live view and the Metadata Monitor use it; nothing changes on the camera. -
Live view: decoding on the graphics card (Settings > This computer > "Decode video on the graphics card", on by
default). The client tests the graphics card at every start in a separate process; when it does not work the processor
decodes and the live view shows what to do (Linux: install the video driver of the graphics card). -
Live view: fullscreen (button top left or double-click; Esc closes) with a stream of its own at the size of the
screen, and Adaptive or Full quality (button top left). -
Settings > This computer: Show video details over the picture (codec, resolution, frame rate, bitrate, graphics
card or processor) and Frame rate (adaptive quality), 20 by default.
Fixed
- A logout, a new password or a disabled user now ends that user's open live views, Web View pages and event streams at
once; a role change can no longer be missed while the user is busy. - Users page: unsaved changes of the permission matrix survive a reconnect and adding a user; a save made on an older
matrix is refused instead of undoing another administrator's change; rows no longer show the wrong permission after
collapsing a group or searching. - Web View: devices that need a login or a password get no requests from open tabs; turning the plugin off stops open
tabs; tabs close when the role loses "Open devices"; Reload works every time; tab titles follow a moved device; large
uploads through the web interface keep the server's disk from filling up. - PTZ: a drag can no longer leave the camera turning (a second button, Alt+Tab, closed controls), the stop is never
overtaken by a late move, and choosing the same preset again goes there again. - Zoom and focus: an answer for the previous source no longer lands on the new one.
- RTSP port: setting it for many cameras is one write, and the live view really uses the new port at once.
- Add devices: "Save to credential list" is for administrators only.
Changed
- Live view: the resolution follows the size of the picture and changes without a gap: the old picture stays until the
new one is there. The video stops 2 seconds after it is hidden (another page, a minimized window) and starts again
when shown. - Live view: the picture area shows only the picture, a progress ring or an error. Fullscreen, quality and the source
buttons show when you point at the picture; zoom, focus and PTZ open with a button at the bottom right. The header
shows the model and the source name. - Metadata Monitor: the RTSP port field moved to the device list (OADM > RTSP port).
- Live view: the video uses 16:9 whenever the camera offers it, also on cameras with a 4:3 sensor.
- Live view: the video details are a small card at the top right with one line each (codec, resolution, frame rate,
bit rate, decoding), so the zoom, focus and PTZ controls keep the bottom. - Live view: zoom, focus and PTZ are shown when the live view opens, in one row with the Controls button.
- RTSP port dialog: a shorter text above the port.