v2.0.0 - Browser configuration, multiple sensors and redesigned dashboard
Version 2.0.0 is a large update: everything is now configured in the browser, multiple RS-485 buses with multiple sensors are supported, and the dashboard has been redesigned.
Highlights
Redesigned dashboard
- Board view: every sensor as one row with temperature, humidity, dew point, absolute humidity, comfort, a 24-hour trend and its status: all sensors at a glance.
- Meters view: one panel per sensor with large values.
- Dark and light theme, chosen in Settings; mobile layout for phones and tablets.
- Status per sensor: OK, warning, alarm or offline, with the out-of-limits value highlighted.
- One chart with a tab per quantity; every sensor keeps its own colour everywhere.
Multiple buses and sensors (#18)
- Several USB/RS-485 interfaces, each with several Modbus slaves.
- Per sensor: name, slave ID, function code, registers and scale (XY-MD02, XY-MD04 and similar).
- A failing sensor or unplugged interface no longer affects the others and is retried automatically.
Settings in the browser
- New Settings tab for buses and sensors, display, region, data retention, server and security.
- Admin password for Settings, optionally for the whole app.
Notifications
- Telegram and e-mail (SMTP) alerts when limits are exceeded (for all sensors or per sensor), when values are back to normal and when a sensor goes offline.
MQTT
- Publishes the values of every sensor to an MQTT broker (Home Assistant, Node-RED, SCADA).
Run as a service
- Install scripts for Linux/Raspberry Pi (systemd) and Windows: the app starts at boot, also without anyone logged in.
Translations
- All texts available in Dutch, English, German, French and Spanish.
Fixes
- Negative temperatures are now read correctly (signed registers).
- A missing serial port at startup no longer stops data collection permanently.
- Security hardening of login sessions, redirects and stored passwords.
Upgrading from 1.x
- Existing data is kept. The Modbus settings from
.envbecome Bus 1 / Sensor 1 automatically; all existing measurements belong to that sensor. DATA_RETENTION_DAYS,DEBUG_LOGGING,TIMEZONEandDEFAULT_LANGUAGEfrom.envare taken over once; after that the Settings tab is leading.- Listen address and port are set in the Settings tab (default
0.0.0.0:8050). - On first visit of the Settings tab you create an admin password.
- New dependency:
paho-mqtt— runpip install -r requirements.txt(or re-run the service install script). - Requires Python 3.10 or newer.