IDEC-TUI

An interactive terminal for communicating with IDEC MicroSmart PLCs over the IDEC Maintenance Protocol.

IDEC-TUI provides a persistent command shell around MiSmSerial.py. It is intended for maintenance, testing, register inspection, diagnostics, and direct PLC interaction without opening WindLDR.

IDEC-TUI terminal

Current capabilities

  • Interactive serial connection to an IDEC PLC
  • Persistent connection settings
  • Command history and tab completion
  • Read and write word registers
  • Read and write individual bits
  • Read inputs and control outputs using I and Q aliases
  • Read and write IEEE-754 floating-point values
  • Read timer information and write timer or counter values
  • Read PLC error-code words
  • Read and write blocks of registers
  • Read and write multi-register unsigned integers
  • Automatic Maintenance Protocol BCC-mode detection
  • Optional raw TX/RX debugging
  • PLC clock setting from the host computer
  • Hardware and health diagnostics through the check command
  • Direct access to additional public MiSmSerial methods

The interactive TUI currently uses the serial Maintenance Protocol. The repository also contains TCP, SD-card, and HMI-related libraries, but those are not the active transport used by hoc_tui.py.

Compatibility

The current implementation has been exercised with FC5A and FC6A hardware over USB serial connections.

The Maintenance Protocol is shared across several IDEC MicroSmart generations, so some earlier CPUs may also work. CPU identification is intentionally conservative:

  • Legacy D8002 CPU codes are reported as FC5A or earlier
  • The broad CPU class, such as 10-I/O, is printed when known
  • Unique FC6A CPU codes are identified directly
  • Attached expansion modules are checked independently from the CPU generation

Exact CPU and module identification depends on the information exposed by the PLC. Some older expansion modules may not have a known type mapping.

Requirements

  • Python 3.10 or newer
  • pyserial
  • A serial or USB Maintenance Protocol connection to the PLC
  • readline for history and tab completion on Linux and macOS

Install the Python dependency with either:

python3 -m pip install pyserial

or on Debian, Ubuntu, and Linux Mint:

sudo apt install python3-serial

Installation

git clone https://github.com/FOSSBOSS/IDEC-TUI.git
cd IDEC-TUI
chmod +x hoc_tui.py
./hoc_tui.py

The program is currently run directly from the source tree. hoc_tui.py and MiSmSerial.py must remain importable from the same project directory.

Linux serial permissions

The current user must have permission to access the serial device. On many Linux systems, that means membership in the dialout group:

sudo usermod -aG dialout "$USER"

Log out and back in after changing group membership.

Common PLC serial devices include:

/dev/ttyACM0
/dev/ttyACM1
/dev/ttyUSB0

Quick start

Start the terminal:

./hoc_tui.py

Configure the connection:

plc[disconnected]> config

Typical USB settings are:

Port: /dev/ttyACM0
Device: FF
Baud: 9600
Timeout: 1.0
Bytesize: 8
Parity: N
Stopbits: 1
Debug: n
BCC mode: auto

Connect and read a register:

plc[disconnected]> connect
Connected to /dev/ttyACM0 (baud=9600, device=FF, bcc_mode=auto)

plc[connected]> read D8002
0

Disconnect or quit:

plc[connected]> disconnect
plc[disconnected]> q

Saved settings and history

Connection settings are saved to:

~/.plc_terminal_config.json

Command history is saved to:

~/.plc_terminal_history

On systems with readline, the up and down arrow keys navigate command history and Tab completes commands, methods, and common register names.

Built-in commands

Command Description
config Configure and save serial connection settings
connect Open the configured serial connection
disconnect Close the current serial connection
status Show connection state and saved configuration
check Run the bundled PLC diagnostic and return to the TUI
set-time Set the PLC clock from the host computer
methods List supported and dynamically detected methods
help Show command help
clear Clear the terminal
q, quit, exit Exit IDEC-TUI

PLC commands

Word registers

read <address>
write <address> <value>

Examples:

read D0100
write D0100 42
read D8005

read returns an unsigned 16-bit value from 0 through 65535.

Bits

read_bit <address>
write_bit <address> <0|1>

Examples:

read_bit M0000
write_bit M0000 1
read_bit M8004.15
write_bit M8004.15 0

The word.bit form reads or modifies one bit within a word value.

Physical inputs and outputs

input <address>
output <address> <0|1>

Examples:

input I0
input X0
output Q0 1
output Q0 0

I is accepted as an input alias for X. Q is accepted as an output alias for Y.

Floating-point values

read_float <address> [endian]
write_float <address> <value> [endian]

Examples:

read_float D0200
read_float D0200 1
write_float D0200 12.5

The optional word-order argument is:

0 = low word first
1 = high word first

Timers and counters

read_timer [timer_number] [count]
write_counter <counter_number> <preset>

Examples:

read_timer
read_timer 0 4
write_counter 10 500

PLC error words

read_error [address] [number_of_bytes]

Examples:

read_error
read_error 0 12

The default reads the six documented error-code words.

Additional MiSmSerial methods

When connected, methods also lists additional public methods found on the current MiSmSerial object. These methods can be called directly from the TUI.

Examples:

read_block D0100 4
read_uint D0105 2 1
write_block D0100 [1, 2, 3]
write_uint D0105 69420 2 1
write_timer 420 100

Arguments are parsed as Python-style values where possible. Decimal, binary, octal, hexadecimal, booleans, strings, lists, and numeric values can be used:

42
0x002A
0b101010
true
[1, 2, 3]

Automatic BCC mode

The serial Maintenance Protocol does not use the same request-BCC convention on every CPU, adapter, or bridge.

The available modes are:

auto
enq
no_enq

auto first tries a BCC that includes the ENQ byte. If the PLC returns NAK code 10, the request is retried without ENQ in the BCC calculation. The successful mode is retained for the current connection.

Use auto unless a specific connection requires a fixed mode.

Debug output

Enable debug in config to print Maintenance Protocol traffic:

TX(ascii): FF0RD800202
TX(hex):   05464630524438303032303232420d
RX(hex):   063031303030303033370d

This is useful for protocol investigation, BCC troubleshooting, and comparing requests with WindLDR captures.

PLC diagnostic

The check command launches the bundled debug.py diagnostic. In the current layout, hoc_tui.py expects it at:

SERIAL/debug.py

The diagnostic can:

  • Scan available serial ports for a responsive PLC
  • Report the host operating system and current host time
  • Report the connected serial device
  • Read the CPU type code from D8002
  • Report a legacy CPU as FC5A or earlier with its broad I/O class
  • Read the connected expansion-module count from D8037
  • Identify known expansion modules from the D8470 register range
  • Decode the D8005 general-error bitfield
  • Read selected PLC status bits
  • List active outputs
  • Read the raw D8056 value
  • Read the firmware version from D8029
  • Read the PLC date and time

Example:

plc[connected]> check
Running diagnostic: .../SERIAL/debug.py
Disconnected.

PLC connection: OK on /dev/ttyACM0
Hardware inventory:
  CPU type D8002: 0x0000 (0)
  CPU: FC5A or earlier CPU detected
  CPU class: 10-I/O
  Connected expansion modules: 2 (D8037)
  Expansion slot 1: FC6A-J4CN1
  Expansion slot 2: FC6A-J4CN1

Diagnostic finished with exit code 0
Connected to /dev/ttyACM0

When check is started from an active TUI connection, the TUI closes the port, runs the diagnostic, and then attempts to reconnect using the saved configuration.

Setting the PLC clock

With the PLC connected:

plc[connected]> set-time

This writes the host computer's current local date and time to the PLC clock registers and applies the new clock value.

Safety

This project can write directly to PLC registers and physical outputs.

Commands such as these can immediately alter machine behavior:

write
write_bit
output
write_block
write_uint
write_timer
write_counter
force
force_io

Before writing:

  • Confirm the correct PLC is connected
  • Confirm the register or output address
  • Make sure the machine is in a safe state
  • Do not rely on software alone for emergency-stop or safety interlocking
  • Avoid forcing outputs on operating equipment unless the consequences are fully understood

The TUI exposes additional public library methods dynamically. That is useful for development, but it also means advanced or experimental methods may be available from the prompt.

Current limitations

  • The interactive TUI currently connects through MiSmSerial
  • Operand addresses currently use the four-digit registers
  • Exact CPU generation cannot always be determined from D8002
  • Hardware type tables are incomplete for modules older than FC5A
  • The TUI does not currently upload or download PLC user programs
  • This is not a replacement for WindLDR project editing
  • Hardware and protocol support is still being validated across PLC generations

Repository files

File Purpose
hoc_tui.py Interactive terminal application
MiSmSerial.py Serial Maintenance Protocol client
SERIAL/debug.py PLC connectivity, health, CPU, and module diagnostic
setTime.py Standalone PLC clock-setting utility

License

IDEC-TUI is released under the MIT License. See LICENSE for the complete license text.

Project status

IDEC-TUI is usable for direct serial maintenance work, register inspection, and diagnostics, but it remains an active protocol-development project. Raw protocol debugging and conservative hardware reporting are intentional parts of the current design.

Tested on Hardware:

CPU Series Modules: FC5A, FC6A

Expansion Series modules: FC4A, FC5A, FC6A

Exact compatabliity is unknown, but modules remained responsive with a wide array of mixxing and matching hardware. Responsive hardware does not mean supported operation.

FC5A Stack used in tui.png

Further testing on FC6A

About

An interactive termnial for commanding your IDEC PLC.