This custom Home Assistant integration provides monitoring and control capabilities for Renogy devices over Bluetooth Low Energy (BLE). Charge controllers and DCC chargers use BT-1 or BT-2 modules. Supported batteries, inverters, and Smart Shunt 300 devices advertise directly over BLE.
Disclaimer: This integration is experimental software. Use caution when controlling electrical loads, and ensure any connected equipment is properly rated and protected.
Supported device families:
- Renogy charge controllers using BT-1 or BT-2, including Rover and Wanderer
- Renogy DC-DC chargers using BT-1 or BT-2, including DCC and RBC model families
- Renogy batteries using the legacy, Battery Pro, or RNGPRO protocol:
- Legacy
BT-TH-*names containingBATTorBATTERY - Battery Pro names beginning with
RNGRBPorRNGC - RNGPRO-family names beginning with
RNGPRO - Battery Pro advertisements containing manufacturer ID
0xE14C
- Legacy
- Renogy inverters advertising
RNGRIU* - Renogy Smart Shunt 300 devices advertising
RTMShunt300*
Expected to work, but not yet confirmed:
- Renogy Adventurer
Support is protocol-family based, so behavior can vary by model and firmware. When reporting a problem, include the exact model, Bluetooth name, integration debug logs, and a comparison with the Renogy app.
- Automatic discovery of Renogy BLE devices
- Automatic discovery of supported Renogy battery advertisements
- Automatic discovery of Renogy inverter devices advertising
RNGRIU* - Automatic discovery of Smart Shunt 300 devices advertising
RTMShunt300* - Monitor battery status (voltage, current, temperature, charge state)
- Monitor solar panel (PV) performance metrics
- Monitor load status and statistics
- Monitor inverter AC output, frequency, load power, temperature, and diagnostic metadata
- Monitor Smart Shunt voltage, current, power, state of charge, and derived energy
- Turn the DC load output on/off (supported controllers only)
- Configure supported DCC charging parameters, battery type, and maximum current
- Monitor controller information
- Telemetry exposed as Home Assistant sensors
- Energy dashboard compatible sensors
- Configurable polling interval
- Automatic error recovery
- Home Assistant instance (version 2026.3 or newer)
- A compatible Bluetooth adapter on your Home Assistant host device
- Bluetooth discovery enabled in Home Assistant
Includes Amazon affiliate links which provide a small commission to support this project.
- Compatible Renogy device (see above)
- Charge controllers and DCC chargers require a BT-1 or BT-2 Bluetooth module.
- Supported Renogy batteries use their built-in BLE radio.
- Renogy inverters advertise directly over BLE as
RNGRIU*. - Smart Shunt 300 devices use their built-in BLE radio and do not require a BT-1 or BT-2 dongle.
- Make sure to purchase the correct module for your device. Different devices use different ports.
- Bluetooth radio for Home Assistant
- ESP32 for Bluetooth proxy (Recommended)
- USB Bluetooth adapter
This integration can be installed via HACS (Home Assistant Community Store).
- Ensure you have HACS installed
- Search for "Renogy" in the HACS store and install it
- Restart Home Assistant
The integration is configurable through the Home Assistant UI after installation:
- Go to Settings > Devices & Services
- Click the "+ Add Integration" button
- Search for "Renogy" and select it
- The integration will automatically start scanning for devices
- Polling Interval: Adjust how frequently the device is polled (10-600 seconds, default: 60)
- Can be configured per device in the device settings
- Lower values provide more frequent updates but may impact battery life
- Connection Mode: Starting in
0.6.0, devices expose connection mode options in the config entry options flow- Smart Shunt 300 devices support
sustainedandintermittent - Batteries, controllers, DCC chargers, and inverters support
intermittentandpersistent_session - See docs/connection-modes.md for behavior and recommendations
- Smart Shunt 300 devices support
- Inverter Profile: Inverter entries can use the generic register layout or
the model-specific
RIV4835CSH1Sprofile- Existing entries can switch profiles through Reconfigure without being deleted
- See docs/inverter-profiles.md for selection guidance
The integration provides the following sensor groups:
- Voltage
- Current
- Temperature
- State of Charge
- Charging Status
- Voltage
- Current
- Power
- Temperature
- State of Charge
- Remaining and rated capacity
- Cycle count
- Cell count and voltage diagnostics, when reported
- Protection status, when the protocol exposes it
- Voltage
- Current
- Power
- Daily Generation
- Total Generation
- Status
- Current Draw
- Power Consumption
- Daily Usage
- Battery Voltage
- AC Output Voltage
- AC Output Current
- AC Output Frequency
- Input Frequency
- Load Active Power
- Load Apparent Power
- Temperature
- Device ID
- Model
Some Renogy charge controllers expose a controllable DC load output. This integration creates a switch entity that can turn the DC load on or off.
Caution: This feature is experimental. Write commands may be interpreted differently by devices or firmware versions, which could cause unexpected load behavior. Use appropriate fusing and wiring, and verify behavior in a safe test setup before relying on it.
Supported DC-DC chargers also expose configuration entities for battery type, maximum charging current, charging voltages, protection thresholds, charge timing, temperature compensation, and solar cutoff current.
Caution: DCC configuration writes change charger behavior. Confirm that every value is appropriate for the connected battery and electrical system before applying it.
- Temperature
- Device Information
- Operating Status
- Shunt Voltage
- Shunt Current
- Shunt Power
- Shunt State of Charge
- Shunt Charge Status
- Shunt Energy
Caution: Shunt support is experimental.
All sensors are automatically added to Home Assistant's Energy Dashboard where applicable.
It can be extremely helpful to enable debug logging when troubleshooting issues.
- Open your Home Assistant instance and navigate to the Renogy integration
- Select "Enable debug logging"
- Navigate to the Home Assistant Core logs
- Select the three dots in the top right and choose "Show raw logs"
- Verify the device is supported by this integration
- For controllers or DCC chargers, confirm a BT-1 or BT-2 module is installed
- For batteries, confirm the advertisement matches one of the documented battery names or manufacturer IDs
- For inverter devices, confirm the BLE name starts with
RNGRIU - For Smart Shunt 300 devices, confirm the BLE name starts with
RTMShunt300 - Check that Bluetooth is enabled on your Home Assistant host
- Ensure the device is within range (typically 10m/33ft)
- Restart the Bluetooth adapter
- If the device shows as unavailable:
- Check the device is powered on
- Verify it's within range
- Check Home Assistant logs for specific error messages
- Try reducing the polling interval temporarily for testing
- Verify your device firmware is up to date
- Check the Renogy app to compare readings
- Note that some values (like daily totals) reset at midnight
- Smart Shunt energy is integration-derived rather than read directly from the device
- For bugs, please open an issue on GitHub
- Include Home Assistant logs and your device model information