This custom Home Assistant integration provides monitoring and control capabilities for Renogy devices over Bluetooth Low Energy (BLE). Charge controllers and DCC chargers use BT-1 or BT-2 modules. Supported batteries, inverters, and Smart Shunt 300 devices advertise directly over BLE.

Disclaimer: This integration is experimental software. Use caution when controlling electrical loads, and ensure any connected equipment is properly rated and protected.

Supported Devices

Supported device families:

  • Renogy charge controllers using BT-1 or BT-2, including Rover and Wanderer
  • Renogy DC-DC chargers using BT-1 or BT-2, including DCC and RBC model families
  • Renogy batteries using the legacy, Battery Pro, or RNGPRO protocol:
    • Legacy BT-TH-* names containing BATT or BATTERY
    • Battery Pro names beginning with RNGRBP or RNGC
    • RNGPRO-family names beginning with RNGPRO
    • Battery Pro advertisements containing manufacturer ID 0xE14C
  • Renogy inverters advertising RNGRIU*
  • Renogy Smart Shunt 300 devices advertising RTMShunt300*

Expected to work, but not yet confirmed:

  • Renogy Adventurer

Support is protocol-family based, so behavior can vary by model and firmware. When reporting a problem, include the exact model, Bluetooth name, integration debug logs, and a comparison with the Renogy app.

Features

  • Automatic discovery of Renogy BLE devices
  • Automatic discovery of supported Renogy battery advertisements
  • Automatic discovery of Renogy inverter devices advertising RNGRIU*
  • Automatic discovery of Smart Shunt 300 devices advertising RTMShunt300*
  • Monitor battery status (voltage, current, temperature, charge state)
  • Monitor solar panel (PV) performance metrics
  • Monitor load status and statistics
  • Monitor inverter AC output, frequency, load power, temperature, and diagnostic metadata
  • Monitor Smart Shunt voltage, current, power, state of charge, and derived energy
  • Turn the DC load output on/off (supported controllers only)
  • Configure supported DCC charging parameters, battery type, and maximum current
  • Monitor controller information
  • Telemetry exposed as Home Assistant sensors
  • Energy dashboard compatible sensors
  • Configurable polling interval
  • Automatic error recovery

Prerequisites

  • Home Assistant instance (version 2026.3 or newer)
  • A compatible Bluetooth adapter on your Home Assistant host device
  • Bluetooth discovery enabled in Home Assistant

Hardware

Includes Amazon affiliate links which provide a small commission to support this project.

  • Compatible Renogy device (see above)
    • Charge controllers and DCC chargers require a BT-1 or BT-2 Bluetooth module.
    • Supported Renogy batteries use their built-in BLE radio.
    • Renogy inverters advertise directly over BLE as RNGRIU*.
    • Smart Shunt 300 devices use their built-in BLE radio and do not require a BT-1 or BT-2 dongle.
    • Make sure to purchase the correct module for your device. Different devices use different ports.
  • Bluetooth radio for Home Assistant

Installation

This integration can be installed via HACS (Home Assistant Community Store).

  1. Ensure you have HACS installed
  2. Search for "Renogy" in the HACS store and install it
  3. Restart Home Assistant

Configuration

The integration is configurable through the Home Assistant UI after installation:

  1. Go to Settings > Devices & Services
  2. Click the "+ Add Integration" button
  3. Search for "Renogy" and select it
  4. The integration will automatically start scanning for devices

Advanced Configuration Options

  • Polling Interval: Adjust how frequently the device is polled (10-600 seconds, default: 60)
    • Can be configured per device in the device settings
    • Lower values provide more frequent updates but may impact battery life
  • Connection Mode: Starting in 0.6.0, devices expose connection mode options in the config entry options flow
    • Smart Shunt 300 devices support sustained and intermittent
    • Batteries, controllers, DCC chargers, and inverters support intermittent and persistent_session
    • See docs/connection-modes.md for behavior and recommendations
  • Inverter Profile: Inverter entries can use the generic register layout or the model-specific RIV4835CSH1S profile
    • Existing entries can switch profiles through Reconfigure without being deleted
    • See docs/inverter-profiles.md for selection guidance

Sensors

The integration provides the following sensor groups:

Controller and DCC Battery Sensors

  • Voltage
  • Current
  • Temperature
  • State of Charge
  • Charging Status

Renogy Battery Sensors

  • Voltage
  • Current
  • Power
  • Temperature
  • State of Charge
  • Remaining and rated capacity
  • Cycle count
  • Cell count and voltage diagnostics, when reported
  • Protection status, when the protocol exposes it

Solar Panel (PV) Sensors

  • Voltage
  • Current
  • Power
  • Daily Generation
  • Total Generation

Load Sensors

  • Status
  • Current Draw
  • Power Consumption
  • Daily Usage

Inverter Sensors

  • Battery Voltage
  • AC Output Voltage
  • AC Output Current
  • AC Output Frequency
  • Input Frequency
  • Load Active Power
  • Load Apparent Power
  • Temperature
  • Device ID
  • Model

DC Load Control

Some Renogy charge controllers expose a controllable DC load output. This integration creates a switch entity that can turn the DC load on or off.

Caution: This feature is experimental. Write commands may be interpreted differently by devices or firmware versions, which could cause unexpected load behavior. Use appropriate fusing and wiring, and verify behavior in a safe test setup before relying on it.

DCC Configuration

Supported DC-DC chargers also expose configuration entities for battery type, maximum charging current, charging voltages, protection thresholds, charge timing, temperature compensation, and solar cutoff current.

Caution: DCC configuration writes change charger behavior. Confirm that every value is appropriate for the connected battery and electrical system before applying it.

Controller Info

  • Temperature
  • Device Information
  • Operating Status

Smart Shunt Sensors

  • Shunt Voltage
  • Shunt Current
  • Shunt Power
  • Shunt State of Charge
  • Shunt Charge Status
  • Shunt Energy

Caution: Shunt support is experimental.

All sensors are automatically added to Home Assistant's Energy Dashboard where applicable.

Troubleshooting

Enable Debug Logging

It can be extremely helpful to enable debug logging when troubleshooting issues.

  1. Open your Home Assistant instance and navigate to the Renogy integration
  2. Select "Enable debug logging"
  3. Navigate to the Home Assistant Core logs
  4. Select the three dots in the top right and choose "Show raw logs"

Device Not Found

  1. Verify the device is supported by this integration
  2. For controllers or DCC chargers, confirm a BT-1 or BT-2 module is installed
  3. For batteries, confirm the advertisement matches one of the documented battery names or manufacturer IDs
  4. For inverter devices, confirm the BLE name starts with RNGRIU
  5. For Smart Shunt 300 devices, confirm the BLE name starts with RTMShunt300
  6. Check that Bluetooth is enabled on your Home Assistant host
  7. Ensure the device is within range (typically 10m/33ft)
  8. Restart the Bluetooth adapter

Connection Issues

  • If the device shows as unavailable:
    1. Check the device is powered on
    2. Verify it's within range
    3. Check Home Assistant logs for specific error messages
    4. Try reducing the polling interval temporarily for testing

Data Accuracy

  • Verify your device firmware is up to date
  • Check the Renogy app to compare readings
  • Note that some values (like daily totals) reset at midnight
  • Smart Shunt energy is integration-derived rather than read directly from the device

Support

  • For bugs, please open an issue on GitHub
  • Include Home Assistant logs and your device model information

License

This project is licensed under the Apache License 2.0 - see the LICENSE file for details.

About

Home Assistant integration for monitoring Renogy devices via BLE

Topics

Resources

Contributing

Stars

41 stars

Watchers

2 watching

Forks

Releases

Sponsor this project

Packages

Used by

Contributors

Languages