GPU APC (Automatic Prefix Caching)

GPU APC models vLLM-style Automatic Prefix Caching: full KV-cache blocks that are already resident in GPU HBM are reused across requests (and across turns of the same session) instead of being recomputed. When a new request shares a prompt prefix with something already cached in the GPU, those blocks are matched, ref-counted, and shared — the request skips prefill for the matched tokens.

APC sits above the distributed KV-cache (KVC) tiers. The lookup order for a prefix is fastest-first: GPU APC → CPUMemory → LocalNVMe → DistributedFS. When APC evicts an idle block, it can write it through to the first KVC tier (CPU DRAM) so the prefix is still reusable from a slower tier later.

APC is a per-worker feature implemented in opal/worker/vllm_worker.py; the eviction policy lives in opal/kvcache/eviction_policy.py.

Ready-to-run example

The repo ships a working config with APC enabled:

  • Config: configs/defaults_apc.json — a worker with enable_gpu_apc: true, LRU eviction, and a CPU DRAM tier for evicted-block write-through.

Run it directly:

PYTHONPATH=`pwd`:$PYTHONPATH python ./opal/main.py -c ./configs/defaults_apc.json

To see APC activity in the log (evictions, hits, proactive migration):

OPAL_LOG_LEVEL=INFO PYTHONPATH=`pwd`:$PYTHONPATH python ./opal/main.py -c ./configs/defaults_apc.json

defaults_apc.json ships with two workload stages — a synthetic UniformReqRate stage and an otel trace stage. APC works with either; multi-turn / agentic workloads (the otel stage, see OTel Trace Replay) benefit most because later turns re-hit the prefix cached from earlier turns.

The parts of defaults_apc.json that drive APC

APC is configured entirely inside worker.vllm_params, with two other sections mattering for capacity and write-through: worker.hw (how much HBM exists) and kvc (where evicted blocks go).

1. worker.vllm_params — the APC knobs

"vllm_params": {
  "enable_gpu_apc": true,        // master switch — nothing below matters if false
  "apc_eviction_policy": "lru",  // which policy decides what to evict
  "apc_lru_ttl": 0,              // seconds a block is immune to eviction after last access
  "block_size": 16,              // KV block granularity (tokens per block == hashing unit)
  "gpu_memory_utilization": 0.9, // (standard vLLM) fraction of HBM usable for KV cache
  "max_num_seqs": 256,
  "max_num_batched_tokens": 8192,
  "max_kvc_ready_requests": 8,
  "chunked_prefill": true
}
Key Default What it does
enable_gpu_apc false Master switch. Must be true to turn APC on. When off, no APC state is allocated and the eviction monitor never starts.
apc_eviction_policy "lru" Which eviction policy to instantiate. Currently only "lru" is implemented (make_apc_policy raises on anything else).
apc_lru_ttl 0 Seconds a block stays immune to eviction after its last access. 0 = no TTL (evict purely by recency). A positive value protects hot prefixes from being evicted under a short burst — evict() skips any idle block still inside its window.
block_size 16 Tokens per KV block. This is also the APC hashing granularity — one cached block == block_size tokens == one physical GPU block. Smaller blocks = finer prefix sharing but more hashing overhead.
gpu_memory_utilization 0.9 Standard vLLM knob: fraction of GPU memory available for KV cache. Together with worker.hw.memory_gb it sets total_gpu_blocks, which caps how much can live in APC.

Two additional, optional knobs control proactive eviction (draining idle APC blocks to CPU DRAM before HBM fills up). They aren't in the shipped file but are read if present:

Key Default What it does
hbm_eviction_threshold 0.9 When idle-APC utilization of non-active GPU capacity exceeds this fraction, the background monitor proactively evicts (migrates) blocks to the CPU tier.
apc_eviction_check_interval_sec 1.0 Base interval for the background eviction monitor. It self-tightens toward 0.1 s as utilization climbs above the threshold.

2. worker.hw — how much GPU there is to cache in

"hw": {
  "gpu": "H100",
  "memory_gb": 80,   // HBM per GPU — larger = more APC capacity
  "tflops": 989.5,
  "mem_bw_TBps": 3.3,
  "tp": 1            // tensor-parallel degree; KV cache is spread across TP ranks
}

total_gpu_blocks = (memory_gb * tp * 1024^3 - model_size_bytes) / (block_size * kv_bytes_per_token). More HBM (or higher tp) means more blocks, means a bigger prefix cache and fewer evictions.

3. kvc — where evicted blocks land (write-through target)

"kvc": {
  "kvc_tiers": ["CPUMemory"],
  "chunk_size": 16,          // KVC-tier hashing granularity
  "CPUMemory": {
    "bandwidth_GBps": 50,
    "latency_nsec": 200,
    "concurrency": 1000000,
    "capacity_GB": 8
  }
}

When APC evicts an idle block whose prefix lands exactly on a chunk_size boundary, it fires a background store() to the first KVC tier (CPUMemory here). That prefix can then still be re-fetched from CPU DRAM instead of being fully recomputed. If you list no KVC tiers, evicted blocks are simply dropped (recompute-on-miss).

Keep block_size (APC) and kvc.chunk_size aligned (both 16 here). APC only writes through on chunk-aligned prefixes because the KVC tier re-hashes at its own chunk_size; a mismatch means many evictions are never persisted.

How APC decides what to keep (LRU + ref counting)

  • Ref counting. Every block a request is actively using is pinned (ref_count > 0) and cannot be evicted. When a request finishes with a block it decrefs; the block stays discoverable and shareable but becomes evict-eligible once its count hits 0. Shared prefixes across concurrent requests just bump the same block's ref count.
  • LRU ordering. Only idle (ref_count == 0) blocks sit in the eviction queue, front = least-recently-used. A block released back to idle re-enters at the most-recently-used end. Eviction cost is O(victims), not O(resident) — pinned blocks are never scanned.
  • TTL. With apc_lru_ttl > 0, an idle block still inside its window is skipped (left in place) during eviction.

Tuning APC

Symptom / goal Turn this knob
APC never fills / few hits Workload has little prefix overlap, or total_gpu_blocks is huge — nothing to tune. Try a multi-turn/agentic (otel) workload.
Hot prefixes evicted too eagerly under bursts Raise apc_lru_ttl to protect recently-used blocks for N seconds.
Want more room in APC Raise worker.hw.memory_gb, raise tp, or lower gpu_memory_utilization headroom pressure.
Evicted prefixes aren't reusable later Add / enlarge a CPUMemory tier in kvc and keep chunk_size == block_size.
Proactive migration too aggressive/lazy Tune hbm_eviction_threshold (lower = migrate earlier) and apc_eviction_check_interval_sec.
Finer prefix sharing Lower block_size (e.g. 8) — more sharing, more hashing overhead; align kvc.chunk_size with it.

Verifying APC is working

At OPAL_LOG_LEVEL=INFO you'll see, per worker:

  • GPU APC enabled: policy=LRUPolicy, block_size=16, ... at startup.
  • [LRU.evict] requested=… evicted=… scanned=… ttl_skipped=… eviction_queue=… pinned=… resident=… on each eviction.
  • [APC] [Evict] Memory util=… > eviction threshold=… Proactively migrated N block(s) to CPU DRAM … when the background monitor fires.

Per-tier prefix-cache hit rate (with apc as the fastest tier) is reported in the run's statistics — see Statistics collection and processing. Each simulation run is saved under simulation-runs/sim-…/ (see the README "Output" section).