v0.4.0 – two-phase covers, CEN/CEN+ devices, wall pushbutton events
Three additions: a two-phase travel model for covers, CEN/CEN+ scenario controls as Home Assistant devices with UI-selectable triggers, and a bus event for wall pushbuttons in dimmer mode. Nothing is renamed and no entity_id or unique_id changes; the event-contract changes are additive (a new mac key on the CEN/CEN+ bus events, one new event). A myhome.yaml written for 0.3.x keeps behaving exactly as it did: the cover model and the scenario controls are opt-in through new keys.
Fixed
- Timed cover targets (
set_cover_position, tilt) were cancelled by the gateway: MyHOMEServer1 answers a movement command with a "stopped" frame immediately followed by the "opening"/"closing" one, and that stop was taken as the end of the run, so the shutter ran to the end stop. The stop echo arriving within 1.5 s of our own command is now ignored; real stops (keypad) are still honoured. Found live on the first calibrated shutter. myhome.send_messagecrashed with an internal error on frames that OWNd's typed parser does not model, such as a CEN+ virtual press (*25*21#1*#2##, WHERE starting with#). Well-formed frames are now sent as generic commands; malformed ones raise a proper validation error. Found while testing the scenario controls.
Added
-
Wall pushbutton events. The gateway echoes what a physical light pushbutton sent (
*1*1000#WHAT*WHERE##) right before the actuator answers; those frames were dropped. They are now republished asmyhome_light_pushbutton_event(mac,where,what,event,message). The point is dimmer-mode pushbuttons wired to relays: a hold sendsdim_up/dim_downabout twice a second and nothing else on the bus reflects it, so this is the only way to turn such a button into a dimming remote for, say, a Zigbee bulb. Short presses giveon/offnext to the status the entity already follows. Found on a bedside pushbutton. -
CEN / CEN+ scenario controls as devices, with device triggers and an event entity. A wall keypad has no state, so until now its presses existed only as
myhome_cenplus_event/myhome_cen_eventbus events, usable from YAML and invisible everywhere else. Declaring the control under the newscenario_control:block inmyhome.yamlnow creates a device on the gateway carrying one event entity (event.<name>_scenario_control, state = timestamp of the last press, attributesevent_type,pushbutton,protocol,object/where) and a set of device triggers, so "Button 2 held down on Living Room Keypad" can be picked in the automation editor instead of hand-written event triggers. Both CEN+ (object, buttons 1-32, including the long-press repeat and the four rotary events) and CEN (where, buttons 0-31) are supported;buttonsdecides which combinations the picker offers, never what reaches the bus. Controls that are not declared keep firing the bus events and create nothing, exactly as in 0.3.x.The device-trigger module is ported from fedem95/MyHOME by fedem95 (AGPL-3.0): the base-schema extension, the type/subtype split and the delegation to Home Assistant's own event trigger are theirs; the concept was also explored by mantovanellimatteo/MyHOME. The event-entity model is ported from adrael/MyHOME by raphael (AGPL-3.0), whose
event.pyimplements the same shape for a doorbell.See Configuration → Scenario control and Recipes → Device triggers and blueprints.
-
macin themyhome_cenplus_event/myhome_cen_eventpayloads. Additive: the existingobject,pushbuttonandeventkeys are untouched, so automations written before 0.4.0 keep matching. It carries the normalised MAC of the gateway that saw the frame, so a multi-gateway plant can tell two controls with the same object number apart — which is what the device triggers filter on. Suggested by fedem95, whose fork adds the same key. -
Two automation blueprints, in
blueprints/automation/myhome/:cenplus_button_light.yaml(short press toggles a light, long press turns it off) andcenplus_button_cover.yaml(hold up/down to open/close a cover, short press to stop). HACS does not install blueprints, so they are imported by URL — see Recipes → Importing the blueprints. -
Two-phase travel model for basic covers (
slat_time). On most roller shutters the motor run is not all lift: from fully closed the first seconds only tilt the slats ("lamelle") open while the curtain stays on the floor, and when closing the motor keeps running for the same few seconds after the curtain has touched the floor, to close them again. The linear 0-100 estimate therefore reported "5 %" with the curtain still on the floor, and set position 50 % from closed ended around 55-60 %. Declaringslat_time(seconds, default0= previous behaviour) splits every run into a slat phase and a curtain phase:current_positionnow describes the curtain only —0= curtain on the floor whatever the slats do,100= fully open;current_tilt_positiondescribes the slats —0= closed,100= open — and the cover isclosedonly when both are0;- the tilt services (
cover.open_cover_tilt,cover.close_cover_tilt,cover.set_cover_tilt_position,cover.stop_cover_tilt) appear on covers with aslat_time, which makes "closed with the slats open" a single service call; above the floor the slats are always open, so tilt commands are ignored there; cover.set_cover_positioncomputes the run through both phases (from closed, 5 % costsslat_time + 0.05 × (opening_time - slat_time)seconds), and movements started from a physical keypad are tracked through the same model.
See Configuration → The two-phase travel model and Recipes → Covers.
-
Separate
opening_timeandclosing_timefor basic covers. Both default toshutter_run, which stays the one value most installations need; set them when the motor is measurably slower in one direction. The idea of separate up/down travel times comes from andrea-parisi/MyHOME. -
Basic covers expose
Slat time,Opening timeandClosing timeas extra state attributes when those keys are in use, next to the existingShutter run.
Changed
cover.set_cover_positionwith a target of0or100now runs the cover into its end stop instead of stopping it with a timer at the computed moment. The end stop is what re-calibrates a time-based estimate, and the stop command was redundant there.- The estimated tilt is persisted next to the position, so "closed with the slats open" survives a restart or a reload.