Repository navigation
ClearPlan v3.1.0
ClearPlan v3.1.0
ClearPlan v3.1.0 is the simulator-backed technical-note release. It provides a
patient-free way to inspect the integrated plan-review interface and preserves
a separate locally built Eclipse/ESAPI mode.
Highlights
- Vendor-free Windows x64 simulator with seven deterministic synthetic
scenarios - Integrated overview plus focused PQM, PlanCheck, field-name, and wide DVH
pages - Read-only field-ID and PlanFieldNamer-compatible name conformance, including
couch-before-direction ordering such as179-181 T30 UZ - RefDB JSON and Excel workbook sources normalized into one validated catalog
- Bounded optional network-source loading and last-valid workspace retention
- Versioned neutral
ReviewSnapshotused by the simulator and Eclipse host - Illustrative, unvalidated, read-only RayStation adapter example
- Reproducible ZMP Short Communication manuscript, three synthetic figures,
and machine-readable evidence - Proposed local commissioning scaffold that clearly separates public
regression fixtures from site-specific clinical acceptance
Verification
- 125 C# tests, zero failures
- 20 Python RayStation-example tests, zero failures
- Python fake-context export accepted by the C# snapshot validator with zero
issues - Seven simulator scenarios validated
- Deterministic UI captures and DVH export verified
- Synthetic PDF report generated and validated
- Cross-runtime deterministic ZIP verified with Windows PowerShell 5.1 and
PowerShell 7.4 - Public workbook validated: 3 tables, 19 constraints, 7 structures
- Source, settings, Office XML, vendor-dependency, version, and privacy guards
passed
Start modes
The attached ClearPlan-Simulator-v3.1.0-win-x64.zip runs without Eclipse,
ESAPI, proprietary TPS assemblies, or patient data. Start
ClearPlan.Simulator.exe and select a scenario, or pass
--scenario mixed-review.
The Eclipse/ESAPI runner remains a separate local build. It requires
institution-approved vendor assemblies, a locally commissioned constraint
catalog and PlanCheck implementation, and site-specific validation. Licensed
vendor assemblies are not included in this release.
The RayStation adapter under examples/raystation is an illustrative contract
example only. It has not been runtime-validated or clinically commissioned.
Evidence boundary
All results in the technical note are deterministic and synthetic. This
release does not establish clinical sensitivity, specificity, false-positive
rate, workflow efficiency, error reduction, or patient-safety benefit.
The .sha256 asset contains the SHA-256 checksum of the simulator archive.