Skip to content

commands

Eric Busboom edited this page Aug 31, 2026 · 2 revisions

Command reference

Every subcommand and flag, the exit-code contract, and the stdout/stderr split.

Command reference

mbdeploy [--version] [--agent] <subcommand> [options]

mbdeploy --help and mbdeploy <subcommand> --help are always authoritative; this page is the same surface written out with the reasoning attached.

Top-level flags

Flag Effect
--version Print the installed version and exit.
--agent Print the bundled agent manual to stdout and exit.
-h, --help Print usage and exit.

--version and --agent are handled before a subcommand is required, so both work on their own.

Conventions that apply everywhere

  • Exit code 0 means success. Check it; never infer success from stdout text. Full contract below.
  • stdout carries data, stderr carries status. See Output streams.
  • --config PATH overrides the registry location on every subcommand that reads or writes it: deploy, list, probe, connect, and serve.
  • Options may appear anywhere, including between two positional arguments. mbdeploy connect tovez --baud 9600 "HELLO" parses the way it reads; plain argparse cannot do this, so every subparser opts into intermixed parsing explicitly.
  • All project paths are relative to the current working directory.

build

Compile the firmware by shelling out to the project's build script.

Flag Effect
--clean Clean before building (passes --clean to the build script).
--verbose Show full build output (passes --verbose).
-j N Build with N parallel jobs (passes -j N).
--build-cmd CMD Replace the whole build command. Split on whitespace.

Without --build-cmd, the command is <python> build.py in the current directory. If build.py is not there and no --build-cmd was given, build prints an error and exits 1 rather than guessing. The build subprocess's exit code is build's exit code.


deploy

Flash firmware to one board.

mbdeploy deploy [target] [options]
Flag Effect
--build Build before flashing.
--clean Clean before building; implies --build.
-j N Parallel jobs for that build.
--force-relay Allow flashing a board whose role marks it a relay.
--hex PATH Flash this hex instead of ./MICROBIT.hex.
--target-mcu MCU Target MCU for pyOCD (default nrf52833).
--config PATH Registry location.
--remote Flash a board advertising on the LAN instead of a local one. See The remote client.

deploy has no --verbose. Only build does; deploy --verbose is a parse error. --build-cmd is likewise build-only — a deploy --build always runs the default build command.

target is optional; omitted, it auto-picks the unique non-relay registry entry and errors if that is ambiguous. Targeting rules, and why a /dev/… path is handled the way it is, are on The device model. What actually gets run against the board is on Building and flashing.

mbdeploy deploy                     # the only robot on the bench
mbdeploy deploy 2                   # by enum
mbdeploy deploy gopiv               # by five-letter name
mbdeploy deploy /dev/ttyACM0        # whichever board is on that port right now
mbdeploy deploy --build             # build first, then flash
mbdeploy deploy gopiv --clean       # clean build, then flash
mbdeploy deploy 2 --hex build/MICROBIT.hex --target-mcu nrf52833
mbdeploy deploy bridge1 --force-relay

list

Print every board the registry knows, plus anything newly attached.

Flag Effect
--config PATH Registry location.
--fast Skip the live SWD name read for connected boards that have no recorded name.
--target-mcu MCU MCU used for that name read (default nrf52833).
--remote List boards advertising on the LAN instead. --fast and --target-mcu are then ignored — no SWD read happens remotely.

list merges the saved registry with the current live probe list. It reads a name over SWD only for a board that is connected and has no name recorded at all (neither device_name nor board_name) — an entry that already has one is never re-read. --fast skips even those reads, at the cost of showing a blank name for a board nothing has ever recorded.

With no boards known and none attached, list prints no devices found and exits 0.

probe

Actively probe every connected board and update the registry.

Flag Effect
--config PATH Registry location.
--target-mcu MCU MCU used for the SWD name read (default nrf52833).
--clear Empty the registry first, keeping only currently connected boards.

probe refreshes each connected board's port, opens that port and sends HELLO to capture an announcement, and reads the five-letter name over SWD for any board that has none recorded. It then saves the registry and prints the same table list does. Run it whenever ports may have changed — after replugging, or before first use of a board mbdeploy has never seen.

probe --clear is the only operation that removes registry entries.

The table

list and probe print the same table:

ENUM  CONN  DEVICE NAME  COMMON NAME  ROLE          PORT                     UID
1     yes   gopiv        robot        NEZHA2        /dev/cu.usbmodem2121102  9906360200052820…
2     no    tovez                                                            9906360200052820…
  • CONN is yes when the board is attached right now, no when it is only remembered from an earlier probe. Connected boards sort first, then by enum, then by UID; a board with no enum sorts last.
  • PORT is blank for a disconnected board — its remembered port no longer refers to anything.
  • DEVICE NAME is the board's own five-letter name.
  • COMMON NAME is a human label, shown so you can find the board on a desk. It is never a target.

connect

Open a serial session with a board, or send it one line and print the reply.

mbdeploy connect <target> [word ...] [options]
Flag Effect
--baud N Baud rate (default 115200). Ignored under --remote.
--timeout SEC Budget for the whole exchange (default 2).
--config PATH Registry location.
--remote Talk to a board advertising on the LAN instead.

target is required — there is no auto-pick. Everything after it is joined with spaces and sent as a single newline-terminated line, so quoting is optional:

mbdeploy connect tovez "HELLO"
mbdeploy connect tovez SET SPEED 50      # sends "SET SPEED 50\n"
mbdeploy connect tovez --baud 9600 "HELLO"
mbdeploy connect tovez "HELLO" --timeout 5
mbdeploy connect tovez                   # interactive; Ctrl-D or Ctrl-C to exit

Opening the port holds DTR and RTS low, so connecting does not reset the board; whatever it was doing keeps running.

How the reply is bounded

--timeout is the budget for the whole exchange, not a per-read timeout:

  • The board has that long to say anything at all.
  • Once it has answered and then stayed quiet for about 0.4 s, the read stops early — so a multi-line reply comes back whole without waiting out the timeout.
  • A board that streams continuously (telemetry, an ack loop) is cut off at --timeout rather than hanging the command.

Raise --timeout for a board that is slow to answer; the same flag caps how much of a chatty board's stream you capture.

One port, one owner

A serial port cannot be shared. connect fails if a monitor, an editor terminal, or another connect already holds the port — and while connect is running, probe cannot read that board's announcement.


serve

Run the fleet daemon. Fully documented on The fleet daemon; the flags are:

Flag Effect
--config PATH Registry location.
--poll-interval SEC Seconds between USB polls (default 2).
--base-port N First of a sequential TCP port pair handed to each board (default 0 — OS-assigned ephemeral ports).
--bind ADDR Address to bind listeners to and advertise (default: all interfaces).
--token SECRET Shared secret clients must send as AUTH <token>. Mutually exclusive with --token-file.
--token-file PATH Read that secret from a file instead, so it never appears in a process listing or in systemctl cat.
--no-flash Reject every FLASH request with ERR flash disabled.
--target-mcu MCU Target MCU for flashes (default nrf52833).
--service-name NAME Override the mDNS instance name for every board this process manages. Only meaningful on a single-board host.
--print-service Render the systemd unit for this exact invocation to stdout and exit, touching nothing.
--install-service Write that unit to disk and exit without running the daemon.
--system / --user Which scope --print-service/--install-service targets. --system is the default.

serve has no --baud: the daemon always opens a board's port at 115200.


Exit codes

0 = success, non-zero = failure. Always check the exit code rather than scraping stdout.

Command Exit code
build The build subprocess's exit code; 1 if build.py is missing and no --build-cmd was given.
deploy 0 on success — specifically, the exit code of the final pyocd reset. See below for the failure cases.
list, probe 0, including when there are no devices at all.
connect 0 when the board answered, or when an interactive session ends. 1 on the failures below.
serve 0 after a clean SIGINT/SIGTERM shutdown; 1 on a startup error such as an unreadable or empty --token-file, or a failed --install-service write.

deploy exits non-zero when:

  • the target token matched no registry entry;
  • a /dev/… path could not be resolved live — nothing on the path, no live map, or the board on it is not in the registry;
  • auto-pick found zero or more than one non-relay entry;
  • the resolved board is a relay and --force-relay was not given;
  • the resolved board is not currently connected;
  • the build step failed — its exit code is propagated;
  • pyocd flash failed and the automatic mass-erase recovery also failed — the erase's or the retried flash's exit code is propagated;
  • pyocd reset returned non-zero.

connect exits non-zero when:

  • the target matched no registry entry, the board is not connected, or it has no serial port;
  • the port could not be opened — wrong path, or another program holds it;
  • a message was sent and nothing came back within --timeout.

That last one is worth internalising: a board running no announcing firmware answers nothing, so connect <board> "HELLO" exits 1 against it. That is correct behaviour, not a fault. See Troubleshooting.

Output streams

  • stdout carries data: the device table, the board's serial reply, the agent manual, the version string, no devices found.
  • stderr carries status: every Error: … line, the interactive-session banner, the mass-erase notice, and relayed flash progress.

For connect the split is a contract, not a convention: the board's reply is the only thing on stdout, so

mbdeploy connect tovez STATUS | grep -q OK

works without the banner contaminating the data.

Notes for scripting

  • Probe before deploying to any board mbdeploy has not seen. The registry entry is what supplies role, and without one deploy refuses a path target rather than flash a board it cannot relay-check.
  • Prefer an enum or the five-letter name over a port path. Ports shift across reconnects; enums and names do not. A path is resolved live, so it is never wrong, but it may name a different board than it did an hour ago.
  • Use connect, not probe, to check that a board is alive. probe rewrites the registry; connect only reads. After a deploy, mbdeploy connect <target> HELLO and check the exit code.
  • Never reflash a relay implicitly. If you mean to, say --force-relay.