Repository navigation
Troubleshooting
First step for almost everything: look at the log, and if that doesn't explain it, enable frame logging (see Configuration) to see everything exchanged with the unit.
- The bridge and the unit must be in the same network segment. Broadcasts don't cross VLANs or routers; guest Wi-Fi and client isolation block them too.
- Ask the unit directly:
java -jar midea2mqtt.jar discover-config --ip 192.168.1.50. That uses unicast and works as long as UDP ports 6445 and 20086 get through. - Look the unit up in your router's DHCP list to get its address.
The unit is V3 and token or key is empty, for example right after discover-config. Fetch them with keys and put them into the config: Finding your units.
- Use the account of the app the unit is really paired with:
--cloud msmart,--cloud nethomeor--cloud mideaair. - Try without
--cloud(shared account), or the other way round. - Make sure the unit is paired and online in the app.
- Wait a minute after the start; the first refresh is slow.
- Wrong
host, or the unit lost its Wi-Fi connection. - Another program holds the connection: Home Assistant's
mideaintegration, a second bridge, thewatchcommand. Stop it. - Authentication errors in the log: token and key belong to another unit, or the unit was reset or paired again. Fetch them again.
- Wrong
protocol. Use what discovery reported.
- Check
mqtt.ipandmqtt.port. - Wrong credentials make the broker refuse the connection; check
usernameandpassword. - Two clients with the same
clientIdkick each other off the broker. Give every bridge its own.
- Watch
<base>/<device>/error:mosquitto_sub -v -t 'midea2mqtt/+/error'. - Is the topic right? The device name is case sensitive and must match the entry in
config.yml. Commands for unknown devices are ignored silently. - Was the command published with the retain flag? Then the log says "Ignoring retained command". Publish without
-r. - Some features simply aren't supported by every unit; check
capabilities.
Something else is controlling it: an automation, a second bridge, or a retained command that was delivered before the bridge ignored retained messages. Clear stray retained messages with mosquitto_pub -t <topic> -r -n.
Try powerAnalysisMethod: 2 or 3 in the device's entry and restart. Different units encode energy differently.
The lib folder isn't next to midea2mqtt.jar. Copy the jar together with the whole lib folder from target/.
The Java version is too old for one of the libraries. Use the version the libraries were built for (Java 21, or 25 if your simplyConfiguration build targets it).