v1.7.6 - I127 SRIM Gap Confirmed Stable
Confirms I127's SRIM stopping-power gap (13%, the largest of the six heavy ions checked in v1.7.5) is a real, stable result rather than a statistics or transcription artifact.
I127 statistics confirmation
- Reran I127's SRIM cross-check at 10x the events (
Macros/run_I127_srim_check_10k.mac, 10000 vs. 1000). - LET moved from 42.736 to 42.782 MeV*cm2/mg (ratio 0.874 -> 0.875) while the mean's standard error shrank from 0.123% to 0.052% of the mean -- essentially no change despite tighter statistics.
- SRIM's 48.92 MeV*cm2/mg value was also independently re-checked and confirmed unchanged.
- The 13% gap is real and stable on both sides -- ordinary Geant4-vs-SRIM stopping-power model variation, not a sampling or data-entry artifact. See
Documentation/PANDA_VALIDATION_SUMMARY.mdSection 1.4.
See README.md for details.