Notifications
You must be signed in to change notification settings - Fork 110
Lights configuration
Laurens edited this page Sep 9, 2026
·
2 revisions
For the lights, the only variation compared to the generic device elements is the dimmable option.
dimmable is an optional boolean defaulting to False that you need to set to True if your device supports dimming. (Only "F418" and "F418U2" DIN modules seem to do to this day)
light:
garage:
where: '01'
name: Garage
dimmable: False
manufacturer: Arnould
model: 64391
dining_room:
where: '17'
name: Dining room
dimmable: False
manufacturer: BTicino
model: F411U2
main_bedroom_1:
where: '23'
interface: '02'
name: Main bedroom
dimmable: True
manufacturer: BTicino
model: F418MyHOME light actuators can run hardware timers directly on the SCS bus. Instead of keeping software delay timers active in Home Assistant (which risk leaving lights ON if Home Assistant restarts or reconnects), you can send native timed turn-on commands (WHAT = 11..18 or Dimension = 2).
See the complete guide and frame syntax in Advanced Uses: Native Bus Timers.