Start with the exact Flow card, variable type, and app version. Change one thing at a time and test with a harmless variable before applying a fix to a production Flow.
- Confirm the Flow is enabled and its trigger event actually occurs.
- Check that the selected variable still exists and has the expected type.
- For A variable changed, confirm the value actually changed; use A variable is set when same-value writes matter.
- For A number variable changed, check direction and minimum amount against old/new values.
- For a sustained trigger, confirm the condition stays true for the entire duration; writes can restart the timer.
- For global/debug triggers, use a selected-variable trigger as a control test. Current source registers a false-returning listener on the global trigger cards, so verify their behavior on your installed version.
- Check that the variable type matches the condition.
- For text conditions, check spaces and case. Comparisons are case-insensitive, but spaces remain significant.
- For number cards, greater-than and less-than are strict; equality is exact.
- Confirm the syntax: Math.js uses
$VariableName$; BLL expressions do not use{[ ]}; embedded text coding does. - Test the expression in BLL settings and check that it returns a boolean.
Variables created through a Flow selector may be removed when no longer referenced by the relevant saved cards. Device and free-text references do not necessarily keep them alive. Create important variables manually in settings, then check type and name before pairing or editing a device.
- BitFlip: verify the variable is boolean.
- NumSlide: verify it is number and within the selected slider range. The driver writes values directly and does not clamp other Flow/API updates.
- Trigger: verify it is still type Trigger.
If the variable is correct, open device settings and re-pair if needed.
Check the output token type and the receiving card’s argument type. A formatted date, number, or duration is text. Base64 is encoded, not encrypted. CSV Base64 has a result-property mismatch in the 4.2.3 development source; use ordinary CSV or test your installed version.