Repository navigation
Troubleshooting
Confirm the plugin JAR is in Fiji.app/plugins/ and restart Fiji. Menu paths are Plugins → srFRC → sFRC, sFSC, and srFRC - resolution mapping.
Check that the plugin and native dependency archives target the same operating system and architecture. Back up incompatible native JARs before replacing them. A separate Fiji copy avoids disruption to unrelated plugins. The macOS ARM64 build has different native and Java-version requirements from Windows/Linux.
Open Image → Properties to inspect the input image's stored calibration. The plugin's editable Pixel Size fields determine the calculation if you enter or confirm different numbers. Use nm for all plugin inputs.
This is intended: Fiji operates on its currently displayed frame/pair. Python and MATLAB default to the first frame in equivalent non-batch modes.
Look at the numeric Float32 map and the displayed colourbar limits. A per-frame colour scale can cause the same nm value to appear in a different colour on another frame. RGB previews are not quantitative data. A colour mismatch between two previews should be investigated as a display-LUT/range issue before assuming numerical differences.
Verify Pixel Size (XY) and Pixel Size (Z), fit angles, cone count and directional cutoffs. Review E_DRI. If the axial result appears implausibly optimistic, compare the manually selected Z Sampling modes; there is no automatic adjustment.
Review the absolute background intensity threshold (0–255 scale) and the sample. Use Monitor Changes to compare background selection on the active frame/pair. Map value 0 is a masked or missing estimate, not an exceptionally sharp region.