Repository navigation
sFRC
Choose Plugins → srFRC → sFRC with a 2D image or frame stack open.
| Dialog field | Default/source | What it controls |
|---|---|---|
Pixel Size |
Image properties or user input | Original XY spacing in nm; input value takes precedence |
If SingleFrame |
true |
Complementary images from the active acquisition; false for adjacent acquired frames |
Threshold |
1/7 hard threshold |
Alternative 3-sigma
|
Stack Batch Processing |
true |
All available frames/pairs or active frame/pair |
Apply Correction |
true |
Analytical correction for single-frame resampling bias |
Show Resampled images |
false |
Optional visual inspection of the generated pair |
Some controls appear under Advanced Settings.
Batch ON processes all available frames or adjacent pairs. For N frames, single-frame mode produces N values; paired mode yields N−1 adjacent pairs. Batch OFF processes the currently displayed frame/pair rather than the first frame by default (different from Python/MATLAB). The sFRC correlation figure is for the current frame/pair only.
The Fiji results window reports resolution (nm) and analysis settings. The correlation plot is shown in its own window. The selected threshold and extrapolation status matter when interpreting the displayed result. Fixed 1/7 extrapolation can be attempted when there is no measured crossing; the 3-sigma criterion is not extrapolated.
For direct raw-image analysis, sFRC's internal diagonal sampling reduces spatial sampling frequency. If the input is undersampled, the resulting estimate may be unavailable or model-dependent. Verify the original physical pixel size and inspect the curve, not only the final number.
srFRCj · Repository · Issues · Documentation
Manuscript: Single-acquisition estimation of anisotropic 3D resolution in super-resolution fluorescence microscopy — publication details pending.