Five things, all of them noise or duplication rather than behaviour.

The tick listener

The TICK_60 subscriber echoed the event header and the payload on every tick, and the listener's
stdout was captured as if it were a log stream. It is not — stdout is how an event listener
answers supervisor (READY, RESULT), so a RESULT line joined the pair.

Two lines a minute, forever, in a container whose whole log is 126 lines. Measured over two ticks:

before after
tick noise in docker logs 4 lines 0

The echo now happens only under DEBUG, where it is still useful, and stdout is no longer
captured on either listener. Verified DEBUG=true still prints the events.

supervisord's own log

Written to /app/var/log/supervisord.log and to the container output, which nodaemon already
gives it. Every line existed twice, and the file sat under two rotators at once: supervisor's
own 50 MB × 10, and logrotate, which matches /app/var/log/*.log.

Gone — along with the Dockerfile line that pre-created it, and the stdout_logfile /
stderr_logfile keys under [supervisord], which are program-section options and were inert
there.

The logrotate listener could die quietly

It ran with autorestart=false, so one crash ended rotation for the life of the container while
everything else kept going — the same silent-failure shape as the configuration bug fixed in #58.
It matches the fail-fast listener now.

And a typo

container-entrypoint-cli still reported success as succesfully; the other entrypoint lost that
one a while ago.

Nothing else moved

Rotation still works, both listeners still answer the protocol (RUNNING), supervisor's own output
still reaches the container log, and /app/var/log is empty at boot instead of holding a file
nothing writes.

nginx  prd   24/24
apache prd   24/24

On the assertion

It reuses the container the suite already has running rather than booting one and sleeping past a
tick. By the time it runs a TICK_60 has usually fired already, so it waits out the remainder and
normally costs nothing — the first version added a flat 70 seconds to every job.

Five things, all of them noise or duplication rather than behaviour.

The TICK_60 subscriber echoed the event header and the payload on every tick,
and the listener's stdout was captured as if it were a log stream. It is not:
stdout is how an event listener answers supervisor -- READY, RESULT -- so a
RESULT line joined the pair. Two lines a minute, forever, in a container whose
whole log was 126 lines. Measured over two ticks before and after:

  tick noise in docker logs   4 lines   0 lines

The echo now happens only under DEBUG, where it is still there for anyone
debugging a listener, and stdout is no longer captured on either listener.

supervisord wrote its log to /app/var/log/supervisord.log as well as to the
container output, which nodaemon already gives it. Every line existed twice, and
the file sat under two rotators at once: supervisor's own 50 MB x 10 and
logrotate, which matches /app/var/log/*.log. The file is gone, along with the
Dockerfile line that pre-created it, and the stdout_logfile keys under
[supervisord], which are program-section options and were inert there.

The logrotate listener ran with autorestart=false, so one crash ended rotation
for the life of the container while everything else kept going -- the same
silent-failure shape as the configuration bug fixed in Smals-Webtech#58. It matches the
fail-fast listener now.

And container-entrypoint-cli still reported success as "succesfully"; the other
entrypoint lost that typo a while ago.

Nothing else moved: rotation still works, both listeners still answer the
protocol, supervisor's own output still reaches the container log, and DEBUG=true
still prints the events.

The assertion added to tests.web.bats reuses the container the suite already has
running rather than booting one and sleeping past a tick -- by the time it runs,
a TICK_60 has usually fired already, so it waits out the remainder and normally
costs nothing.
@zebby76
zebby76 merged commit f01a47b into Smals-Webtech:main Sep 3, 2026
19 checks passed
zebby76 added a commit that referenced this pull request Sep 4, 2026
…ise app-init and fix the docs (backport of #62, #63, #64, #65 to 8.4) (#66)

* chore(supervisor): quieten the startup and tick logging (#62)

Five things, all of them noise or duplication rather than behaviour.

The TICK_60 subscriber echoed the event header and the payload on every tick,
and the listener's stdout was captured as if it were a log stream. It is not:
stdout is how an event listener answers supervisor -- READY, RESULT -- so a
RESULT line joined the pair. Two lines a minute, forever, in a container whose
whole log was 126 lines. Measured over two ticks before and after:

  tick noise in docker logs   4 lines   0 lines

The echo now happens only under DEBUG, where it is still there for anyone
debugging a listener, and stdout is no longer captured on either listener.

supervisord wrote its log to /app/var/log/supervisord.log as well as to the
container output, which nodaemon already gives it. Every line existed twice, and
the file sat under two rotators at once: supervisor's own 50 MB x 10 and
logrotate, which matches /app/var/log/*.log. The file is gone, along with the
Dockerfile line that pre-created it, and the stdout_logfile keys under
[supervisord], which are program-section options and were inert there.

The logrotate listener ran with autorestart=false, so one crash ended rotation
for the life of the container while everything else kept going -- the same
silent-failure shape as the configuration bug fixed in #58. It matches the
fail-fast listener now.

And container-entrypoint-cli still reported success as "succesfully"; the other
entrypoint lost that typo a while ago.

Nothing else moved: rotation still works, both listeners still answer the
protocol, supervisor's own output still reaches the container log, and DEBUG=true
still prints the events.

The assertion added to tests.web.bats reuses the container the suite already has
running rather than booting one and sleeping past a tick -- by the time it runs,
a TICK_60 has usually fired already, so it waits out the remainder and normally
costs nothing.

* chore(nginx): correct the default tuning (#63)

* chore(nginx): correct the default tuning

Seven settings that were inert, disagreed with a neighbouring one, or read the
wrong thing. Measured on smalswebtech/base-php:8.5.9-nginx and on an image built
from this branch.

gzip_types listed application/x-javascript and text/javascript, and mime.types
maps .js to application/javascript. No script this image serves was ever
compressed:

  Accept-Encoding: gzip on a 3 KB .js    no Content-Encoding    Content-Encoding: gzip

worker_processes was auto, which counts the cores nginx can see. A cgroup quota
is not one of them -- only a cpuset is -- so a 500m limit on a large node still
spawned one worker per host core, each carrying its own worker_connections. The
count now comes from the container's CPU allowance, rounded up, and stays auto
when no limit is set:

  --cpus=0.5   8 workers -> 1        --cpus=2.5   8 -> 3
  --cpus=1     8 workers -> 1        no limit     8 -> 8 (auto, 8 host cores)

NGINX_WORKER_PROCESSES overrides it.

client_max_body_size was 1m while PHP's upload_max_filesize is 2M, so nginx
answered 413 on an upload PHP would have accepted -- two limits disagreeing about
the same request. A 1.5 MB body went from 413 to reaching the handler.

/healthcheck and /real-time-status used add_header for their Content-Type, which
appends to the one nginx has already set: two Content-Type headers on the same
response, now one.

location ~ \.php$ cannot match /index.php/fr/blog, so a front controller never
received PATH_INFO and the fastcgi_split_path_info and PATH_INFO lines under it
were dead. apache has always handled this, which left the two variants routing
differently:

  GET /front.php/fr/blog    404    200, path_info=[/fr/blog]

Named captures rather than fastcgi_split_path_info, because try_files resets
$fastcgi_path_info and that is the usual way this ends up empty. try_files still
guards the classic attack: /uploads/photo.jpg/shell.php resolves to a .php that
is not on disk, so it stays a 404 rather than photo.jpg being executed. Asserted
both ways.

limit_req logged a throttled request at error level, dry-run rejections included
-- a policy working as intended filling the error log. NGINX_SOFT_THROTTLE_LOG_LEVEL
defaults to warn.

tcp_nopush only takes effect together with sendfile, which is off by default
here, so it was a setting that did nothing. Left as it was, with a comment
saying so; changing either without the other is what to avoid.

The README also gains the note that both throttling zones key on $remote_addr:
behind a router with NGINX_REAL_IP_ENABLED off, that is the router's address, so
every visitor shares one bucket and the global 20r/s applies to the whole site.

* docs: use the underscore emphasis style the linter expects

MD049: super-linter's markdownlint defaults want underscores, and the note added
alongside NGINX_WORKER_PROCESSES used asterisks.

* fix(app-init): serialise the run-once hooks and document them (#64)

* fix(app-init): serialise the run-once hooks and document them

The marker in /app/var/lock/appinit records whether the hooks have run, not
whether they are running. Replicas sharing the volume it lives on -- an RWX claim
is the usual way sessions and uploads are shared -- read it at the same moment,
all conclude the hooks are pending, and all run them. A migration hook runs once
per replica.

Measured with two containers started together, a hook that occupies three
seconds, and only /app/var/lock and /app/var/log shared:

  published 8.5.9   hook ran 2 times
  this branch       hook ran 1 time

The lock is held across the check, the run and the write, and the marker is read
again inside it, so the second replica finds the work already done and skips.
flock releases on process death, so a container that dies mid-init does not wedge
the others; APP_INIT_LOCK_TIMEOUT bounds the wait at 300s and a replica that
gives up fails its boot rather than run someone else's migration alongside them.

The lock is a separate file from the marker: the marker is rewritten, and locking
a file while truncating it is how this goes wrong.

Note for anyone touching it: the flock in this image is BusyBox's, which takes
-s, -x, -u and -n and nothing else. There is no -w, so the bounded wait is a
retry around the non-blocking form. The first version of this used --timeout,
which BusyBox answers with a usage message and a non-zero exit -- every container
then failed its boot with a lock timeout it had never waited for.

The hook mechanism was also undocumented -- no mention of
/opt/bin/container-entrypoint.d anywhere in the README. It now describes the two
kinds of hook and when each runs, and the three things worth knowing before
writing one: they run once per /app/var volume rather than once per image, so an
ephemeral volume runs them at every start; replicas are serialised; and they see
the environment before it is sanitized, secrets included, so a hook that dumps
env publishes them. The cli variant runs no late hooks at all.

The assertion added to tests.web.bats shares only /app/var/lock and /app/var/log.
Sharing /app/var whole is not a realistic deployment and does not work: the two
supervisords fight over one RPC socket and the second container exits before it
ever reaches its init scripts, which makes the race impossible to observe.

* docs: use the term the linter expects

textlint terminology: "filenames", not "file names".

* docs: correct the drifted documentation, and narrow the rendered credentials (#65)

Six statements that did not describe the image, each rechecked against a running
container before being rewritten.

The README said `PHP_APC_ENABLED=false` disables apcu. The per-extension switch
is built from the extension name -- PHP_APCU_ENABLED -- while PHP_APC_ENABLED is
the apc.enabled ini directive, a different setting that does not disable
anything. Someone following the README turned off nothing and got no warning.

docs/php-fpm.md described CONTAINER_HEAP_PERCENT as auto-sizing the memory pools
and emitting a warning at startup. Nothing reads it and no warning exists; it has
never had an effect.

docs/php.md gave opcache.max_accelerated_files as 4000. The image ships 10000 --
opcache is compiled statically here, so the probe reads its real default rather
than the fallback the table was written from.

The AWS section was the furthest from reality. It described ~/.aws/config and
~/.aws/credentials, which do not exist: the files are /opt/etc/aws/*. And it left
unsaid the thing that matters most, that the entrypoint unsets every AWS_*
variable it resolved before handing over -- measured, an application process sees
none of them, so an SDK in PHP code falls through to instance metadata. Also
recorded: AWS_PROFILE changes nothing, only [default] is ever written; and
AWS_S3_ENDPOINT_URL is read by nothing, the CLI's own AWS_ENDPOINT_URL_S3 being
the variable that works because it carries no default and survives the cleanup.

The supervisor table listed SUPERVISOR_XMLRPC_UNIX_SOCKET_CHOWN as a setting.
The template line was commented out, so it did nothing; the variable and its row
are gone rather than left looking functional. Wiring it is a separate question --
it would let a sidecar with another uid reach the socket, which is a decision, not
a documentation fix.

And the credentials themselves are now written 0600. They were 0664 in a tree
copied with --chmod=777, so the password sat world-readable next to a socket that
is 0700. That is defence in depth only: everything in the container runs as uid
1001, php-fpm included, so an application able to run code reaches supervisor
whatever the password is. The README says so plainly now instead of implying a
boundary that does not exist.

Both documentation linters the workflow runs -- markdownlint and textlint -- pass
locally against the same super-linter image, which is how MD013, MD028 and a
terminology error were caught before pushing rather than after.
@zebby76
zebby76 deleted the fix/supervisor-quieten-logging branch September 4, 2026 16:35
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant