Notifications
You must be signed in to change notification settings - Fork 521
WWSTCERT-8756 Add support to frient air quality sensor #2439
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Merged
greens
merged 11 commits into
SmartThingsCommunity:main
from
marcintyminski:Add-support-to-frient-air-quality-sensor
Nov 18, 2025
Merged
Changes from all commits
Commits
Show all changes
11 commits
Select commit
Hold shift + click to select a range
5b34199
added support to frient air quality sensor
marcintyminski 3f4f15f
delete device:add_monitored_attribute from the driver
marcintyminski 93bdfe2
remove unused variable
marcintyminski 5d13c80
Merge branch 'SmartThingsCommunity:main' into Add-support-to-frient-a…
marcintyminski c39b627
change profile
marcintyminski 32a98e3
Merge branch 'SmartThingsCommunity:main' into Add-support-to-frient-a…
marcintyminski ecd4a3d
removed unused health concern value
marcintyminski 8b6b1b6
Merge branch 'Add-support-to-frient-air-quality-sensor' of https://gi…
marcintyminski 435e85f
Merge branch 'main' into Add-support-to-frient-air-quality-sensor
marcintyminski 77dc48b
Merge branch 'SmartThingsCommunity:main' into Add-support-to-frient-a…
marcintyminski dc86e72
removed log statements
marcintyminski File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
52 changes: 52 additions & 0 deletions
52
...Things/zigbee-humidity-sensor/profiles/frient-airquality-humidity-temperature-battery.yml
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,52 @@ | ||
| name: frient-airquality-humidity-temperature-battery | ||
| components: | ||
| - id: main | ||
| capabilities: | ||
| - id: airQualitySensor | ||
| version: 1 | ||
| - id: tvocMeasurement | ||
| version: 1 | ||
| - id: tvocHealthConcern | ||
| version: 1 | ||
| config: | ||
| values: | ||
| - key: "tvocHealthConcern.value" | ||
| enabledValues: | ||
| - good | ||
| - moderate | ||
| - slightlyUnhealthy | ||
| - unhealthy | ||
| - veryUnhealthy | ||
| - id: relativeHumidityMeasurement | ||
| version: 1 | ||
| - id: temperatureMeasurement | ||
| version: 1 | ||
| - id: battery | ||
| version: 1 | ||
| - id: firmwareUpdate | ||
| version: 1 | ||
| - id: refresh | ||
| version: 1 | ||
| preferences: | ||
| - preferenceId: humidityOffset | ||
| explicit: true | ||
| - title: "Humidity Sensitivity (%)" | ||
| name: humiditySensitivity | ||
| description: "Minimum change in humidity level to report" | ||
| required: false | ||
| preferenceType: number | ||
| definition: | ||
| minimum: 1 | ||
| maximum: 50 | ||
| default: 3 | ||
| - preferenceId: tempOffset | ||
| explicit: true | ||
| - title: "Temperature Sensitivity (°)" | ||
| name: temperatureSensitivity | ||
| description: "Minimum change in temperature to report" | ||
| required: false | ||
| preferenceType: number | ||
| definition: | ||
| minimum: 0.1 | ||
| maximum: 2.0 | ||
| default: 1.0 |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
156 changes: 156 additions & 0 deletions
156
drivers/SmartThings/zigbee-humidity-sensor/src/frient-sensor/air-quality/init.lua
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,156 @@ | ||
| local capabilities = require "st.capabilities" | ||
| local util = require "st.utils" | ||
| local data_types = require "st.zigbee.data_types" | ||
| local zcl_clusters = require "st.zigbee.zcl.clusters" | ||
| local TemperatureMeasurement = zcl_clusters.TemperatureMeasurement | ||
| local HumidityMeasurement = zcl_clusters.RelativeHumidity | ||
| local PowerConfiguration = zcl_clusters.PowerConfiguration | ||
| local device_management = require "st.zigbee.device_management" | ||
| local cluster_base = require "st.zigbee.cluster_base" | ||
| local battery_defaults = require "st.zigbee.defaults.battery_defaults" | ||
| local configurationMap = require "configurations" | ||
|
|
||
| local FRIENT_AIR_QUALITY_SENSOR_FINGERPRINTS = { | ||
| { mfr = "frient A/S", model = "AQSZB-110", subdriver = "airquality" } | ||
| } | ||
|
|
||
| local function can_handle_frient(opts, driver, device, ...) | ||
| for _, fingerprint in ipairs(FRIENT_AIR_QUALITY_SENSOR_FINGERPRINTS) do | ||
| if device:get_manufacturer() == fingerprint.mfr and device:get_model() == fingerprint.model and fingerprint.subdriver == "airquality" then | ||
| return true | ||
| end | ||
| end | ||
| return false | ||
| end | ||
|
|
||
| local Frient_VOCMeasurement = { | ||
| ID = 0xFC03, | ||
| ManufacturerSpecificCode = 0x1015, | ||
| attributes = { | ||
| MeasuredValue = { ID = 0x0000, base_type = data_types.Uint16 }, | ||
| MinMeasuredValue = { ID = 0x0001, base_type = data_types.Uint16 }, | ||
| MaxMeasuredValue = { ID = 0x0002, base_type = data_types.Uint16 }, | ||
| Resolution = { ID = 0x0003, base_type = data_types.Uint16 }, | ||
| }, | ||
| } | ||
|
|
||
| Frient_VOCMeasurement.attributes.MeasuredValue._cluster = Frient_VOCMeasurement | ||
| Frient_VOCMeasurement.attributes.MinMeasuredValue._cluster = Frient_VOCMeasurement | ||
| Frient_VOCMeasurement.attributes.MaxMeasuredValue._cluster = Frient_VOCMeasurement | ||
| Frient_VOCMeasurement.attributes.Resolution._cluster = Frient_VOCMeasurement | ||
|
|
||
| local MAX_VOC_REPORTABLE_VALUE = 5500 -- Max VOC reportable value | ||
|
|
||
| --- Table to map VOC (ppb) to HealthConcern | ||
| local VOC_TO_HEALTHCONCERN_MAPPING = { | ||
| [2201] = "veryUnhealthy", | ||
| [661] = "unhealthy", | ||
| [221] = "slightlyUnhealthy", | ||
| [66] = "moderate", | ||
| [0] = "good", | ||
| } | ||
|
|
||
| --- Map VOC (ppb) to HealthConcern | ||
| local function voc_to_healthconcern(raw_voc) | ||
| for voc, perc in util.rkeys(VOC_TO_HEALTHCONCERN_MAPPING) do | ||
| if raw_voc >= voc then | ||
| return perc | ||
| end | ||
| end | ||
| end | ||
| --- Map VOC (ppb) to CAQI | ||
| local function voc_to_caqi(raw_voc) | ||
| if (raw_voc > 5500) then | ||
| return 100 | ||
| else | ||
| return math.floor(raw_voc*99/5500) | ||
| end | ||
| end | ||
|
|
||
| -- May take around 8 minutes for the first valid VOC measurement to be reported after the device is powered on | ||
| local function voc_measure_value_attr_handler(driver, device, attr_val, zb_rx) | ||
| local voc_value = attr_val.value | ||
| if (voc_value < 65535) then -- ignore it if it's outside the limits | ||
| voc_value = util.clamp_value(voc_value, 0, MAX_VOC_REPORTABLE_VALUE) | ||
| device:emit_event(capabilities.airQualitySensor.airQuality({ value = voc_to_caqi(voc_value)})) | ||
| device:emit_event(capabilities.tvocHealthConcern.tvocHealthConcern(voc_to_healthconcern(voc_value))) | ||
| device:emit_event(capabilities.tvocMeasurement.tvocLevel({ value = voc_value, unit = "ppb" })) | ||
| end | ||
| end | ||
|
|
||
| -- The device sends the value of MeasuredValue to be 0x8000, which corresponds to -327.68C, until it gets the first valid measurement. Therefore we don't emit event before the value is correct. It may take up to 4 minutes | ||
| local function temperatureHandler(driver, device, attr_val, zb_rx) | ||
| local temp_value = attr_val.value | ||
| if (temp_value > -32768) then | ||
| device:emit_event(capabilities.temperatureMeasurement.temperature({ value = temp_value / 100, unit = "C" })) | ||
| end | ||
| end | ||
|
|
||
| local function device_init(driver, device) | ||
| battery_defaults.build_linear_voltage_init(2.3, 3.0)(driver, device) | ||
| local configuration = configurationMap.get_device_configuration(device) | ||
| if configuration ~= nil then | ||
| for _, attribute in ipairs(configuration) do | ||
| device:add_configured_attribute(attribute) | ||
| end | ||
| end | ||
| end | ||
|
|
||
| local function device_added(driver, device) | ||
| device:emit_event(capabilities.airQualitySensor.airQuality(voc_to_caqi(0))) | ||
| device:emit_event(capabilities.tvocHealthConcern.tvocHealthConcern(voc_to_healthconcern(0))) | ||
| device:emit_event(capabilities.tvocMeasurement.tvocLevel({ value = 0, unit = "ppb" })) | ||
| end | ||
|
|
||
| local function do_refresh(driver, device) | ||
| for _, fingerprint in ipairs(FRIENT_AIR_QUALITY_SENSOR_FINGERPRINTS) do | ||
| if device:get_manufacturer() == fingerprint.mfr and device:get_model() == fingerprint.model then | ||
| device:send(cluster_base.read_manufacturer_specific_attribute(device, Frient_VOCMeasurement.ID, Frient_VOCMeasurement.attributes.MeasuredValue.ID, Frient_VOCMeasurement.ManufacturerSpecificCode):to_endpoint(0x26)) | ||
| device:send(TemperatureMeasurement.attributes.MeasuredValue:read(device):to_endpoint(0x26)) | ||
| device:send(HumidityMeasurement.attributes.MeasuredValue:read(device):to_endpoint(0x26)) | ||
| device:send(PowerConfiguration.attributes.BatteryVoltage:read(device)) | ||
| end | ||
| end | ||
| end | ||
|
|
||
| local function do_configure(driver, device) | ||
| device:configure() | ||
| device:send(device_management.build_bind_request(device, Frient_VOCMeasurement.ID, driver.environment_info.hub_zigbee_eui, 0x26)) | ||
|
|
||
| device:send( | ||
| cluster_base.configure_reporting( | ||
| device, | ||
| data_types.ClusterId(Frient_VOCMeasurement.ID), | ||
| Frient_VOCMeasurement.attributes.MeasuredValue.ID, | ||
| Frient_VOCMeasurement.attributes.MeasuredValue.base_type.ID, | ||
| 60, 600, 10 | ||
| ):to_endpoint(0x26) | ||
| ) | ||
|
|
||
| device.thread:call_with_delay(5, function() | ||
| do_refresh(driver, device) | ||
| end) | ||
| end | ||
|
|
||
| local frient_airquality_sensor = { | ||
| NAME = "frient Air Quality Sensor", | ||
| lifecycle_handlers = { | ||
| init = device_init, | ||
| added = device_added, | ||
| doConfigure = do_configure, | ||
| }, | ||
| zigbee_handlers = { | ||
| cluster = {}, | ||
| attr = { | ||
| [Frient_VOCMeasurement.ID] = { | ||
| [Frient_VOCMeasurement.attributes.MeasuredValue.ID] = voc_measure_value_attr_handler, | ||
| }, | ||
| [TemperatureMeasurement.ID] = { | ||
| [TemperatureMeasurement.attributes.MeasuredValue.ID] = temperatureHandler, | ||
| }, | ||
| } | ||
| }, | ||
| can_handle = can_handle_frient | ||
| } | ||
|
|
||
| return frient_airquality_sensor | ||
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Oops, something went wrong.
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
are you expecting to add more models to this sub-driver?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
There is a possibility that we will need to add another model in the near future.