Bug Fixes

Toggling a dishwasher option (ExtraPower, ExtraSilent, etc.) resets all other options

Affected appliance types: Dishwashers where userSelections options are exposed as
switches (e.g. Electrolux 911438465 / model DW-911438465_00).

Symptom: Toggling any userSelections boolean switch — for example turning
Extra Power on or off — would cause all other currently-active options to be
silently reset to false on the appliance. Concretely:

  • Toggle Extra Power ON → Sanitize turns off on the physical panel.
  • Toggle Extra Power OFF → Sanitize turns off on the physical panel.
  • The behaviour was identical regardless of which option was toggled or what the
    new state was.
  • timeToEnd and eco scores changed as a side-effect, confirming the appliance had
    actually received and applied the command.

Root cause — partial userSelections write treated as full replacement

When a switch was toggled, the integration sent a minimal command containing only
programUID plus the single changed field, for example:

{
  "userSelections": {
    "programUID": "ECO",
    "extraPowerOption": true
  }
}

This Electrolux dishwasher firmware interprets a partial userSelections write as a
full replacement: any field absent from the payload is reset to its default value
(false for boolean options). So the command above effectively turned off
sanitizeOption, glassCareOption, autoDoorOpener, and every other option that was
not explicitly listed.

The capability document for this appliance correctly models userSelections as a set of
independent boolean fields (extraPowerOption, extraSilentOption, glassCareOption,
sanitizeOption, autoDoorOpener, …) that are individually "access": "readwrite".
There is no API-level indication that sends partial writes would be destructive, making
this a firmware-level behaviour that must be worked around in the integration.

Fix — send full userSelections payload on every switch toggle

A new helper _build_full_user_selections(changed_attr, new_value) was added to
entity.py. It:

  1. Reads all fields currently present in the reported userSelections dict.
  2. Filters out fields whose capability declares "access": "read" (read-only computed
    fields like ecoScore, energyScore, waterScore) to avoid API validation errors.
  3. Overrides the changed field with the new value (and ensures programUID is always
    present).
  4. Returns the merged dict as the complete userSelections payload.

switch.py now calls this helper for both legacy and DAM appliances whenever
entity_source == "userSelections", so the full current option state is always
preserved on every toggle:

{
  "userSelections": {
    "programUID": "ECO",
    "extraPowerOption": true,
    "sanitizeOption": true,
    "glassCareOption": false,
    "extraSilentOption": false,
    "autoDoorOpener": true,
    "oneRackOption": false,
    "zoneCleanOption": false,
    "sprayZoneOption": false,
    "xtraDryOption": false
  }
}

⚠ Testing required: This change affects all dishwasher (and other appliance type)
userSelections switch entities. After upgrading, please verify:

  • Toggling Extra Power, Sanitize, Glass Care, Extra Silent, or Auto
    Door Opener
    no longer resets the other options on the physical panel.
  • The timeToEnd and eco scores update to values consistent with only the intended
    option change.
  • Programme changes via the select entity continue to work as before.
  • Appliances that do not use userSelections switches are unaffected.