Per-zone chime control
Home Assistant integration 0.6.0 · bridge firmware 0.9.0
- One
selectentity per zone with the panel's six chime types (Off, Voice, Voice and ding-dong, Loud ding-dong, Voice and loud ding-dong, Ding-dong), read back from the panel's zone programming table. - New bridge command topic
panel/zone_chime/set({"zone":N,"mode":M}) mapped to the console'szone_chime <zone> <mode>command through the protected, unlock-supervised path. - Requests that already match the panel's current value are skipped so automations never cause needless settings-flash commits.
- The zone table is re-read shortly after each change so the new value is confirmed from the panel, not the command echo.
- Manifest advertises
zone_chime_control.
Firmware must be updated to 0.9.0 for the chime selectors to become available.