Anker SOLIX X1 — Home Assistant Integration

HACS Custom Validate Buy Me a Coffee

Local Modbus TCP integration for the Anker SOLIX X1 hybrid inverter / battery (developed and tested on X1-H12K-T). No cloud, no internet — Home Assistant talks directly to the unit on your LAN and exposes it as a single device with monitoring sensors and write controls (charge / discharge / idle, work-mode).

Built by reverse-engineering the unit against Anker's X1 Series Modbus Protocol V1.0.0 plus registers discovered on the device, and ground-truthed against live hardware (X1-H12K-T, both DC- and AC-coupled). The diagnostic scripts used to do that live in tools/.


Features

  • Local & cloud-free — direct Modbus TCP, everything stays on your LAN.
  • One tidy device with auto-detected model, firmware and serial.
  • Live monitoring — power flow, PV strings, SOC/SOH, pack voltage, inverter temperature, daily & lifetime energy, plus an optional external-meter block.
  • Real control — battery power setpoint, work-mode selection, and a master Modbus-control switch, with the inverter's comms watchdog as a safety net.
  • Derived metrics computed in the integration — split charge/discharge power, true daily energy (reset at local midnight), and inverter loss.
  • Topology-aware — auto-adapts its charge-power and loss math to DC-coupled vs AC-coupled installs (see the PV connected option).
  • Version-proof — auto-adapts to the pymodbus version Home Assistant ships (slave= vs device_id=).

Requirements

  • An Anker SOLIX X1 with Modbus TCP enabled — in the Anker Solix Professional app → Communication Settings → toggle Modbus TCP on.
  • A wired LAN connection to the inverter is recommended.
  • Home Assistant 2024.1 or newer.

Installation

HACS (recommended)

  1. HACS → Integrations → ⋮ → Custom repositories.
  2. Add https://github.com/afewyards/anker-x1-ha, category Integration.
  3. Install Anker SOLIX X1, then restart Home Assistant.
  4. Settings → Devices & Services → Add Integration → "Anker SOLIX X1" and enter the inverter's IP (port 502, unit id 1 by default).

Manual

Copy custom_components/anker_x1/ into your HA config/custom_components/ directory and restart, then add the integration as in step 4 above.

Entities

All entities live under one Anker X1 device. The identifiers below are the integration's internal keys — the entity's HA name (and hence its entity_id) can differ, e.g. grid_bought_total shows as Grid Bought Today. Several entities are marked Diagnostic and hidden by default; show them from the device page.

Sensors — power (W)

Entity Notes
battery_power + discharging / − charging
charge_power unsigned charge power (0 when discharging)
discharge_power unsigned discharge power (0 when charging)
pv_power gross DC PV = pv1_power + pv2_power (0 with no DC PV)
usable_pv_power inverter's post-MPPT harvested PV total; ≤ pv_power at low irradiance
pv1_power / pv2_power per-string DC power (V × I)
backup_power EPS / backup-port load
meter_total_power external CHINT meter total (only if a meter is wired)
rechargeable_power / dischargeable_power live charge/discharge headroom (diagnostic)
inverter_loss derived conversion loss (diagnostic — see below)

Sensors — battery, energy, status

Entity Unit Notes
soc / soh % state of charge / health (SOH is diagnostic)
battery_pack_voltage V pack DC voltage (reg 10253; unavailable if unimplemented)
battery_module_count installed 5 kWh modules (diagnostic)
battery_nominal_capacity kWh battery_module_count × 5 kWh (diagnostic)
inverter_temperature °C diagnostic
battery_charge_energy / battery_discharge_energy kWh daily, resets at local midnight (derived)
battery_charge_total / battery_discharge_total kWh lifetime
pv_energy_today / pv_energy_total kWh daily / lifetime
grid_bought_total / grid_fed_in_total kWh daily device counters (named Grid Bought/Fed-in Today)
meter_fwd_energy_total / meter_rev_energy_total kWh lifetime, from the external meter (if present)
meter_total_reactive var external meter reactive power (diagnostic)
plant_status / battery_status text enum
output_mode wiring topology (L/N vs three-phase) — diagnostic
meter_comm_status external meter link state — diagnostic
model / serial diagnostic

PV, meter and pack-voltage sensors appear on every install but only carry real values when the corresponding hardware is present and detected. With no DC PV they read 0 (see the PV connected option); with no external CHINT meter the meter_* sensors stay unavailable.

Controls

Entity What it does
switch Modbus Control ON hands the battery to HA (VPP mode); OFF returns it to the app
number Battery Setpoint − = charge, + = discharge, 0 = idle; range follows the inverter's live limits
select Work Mode Self-consumption / Time-of-Use / Backup-only / VPP/3rd-party / User-defined / Socket-aggregation / App-managed

Home Assistant Energy dashboard

Settings → Dashboards → Energy expects kWh totals with the total_increasing state class (all of the sensors below have it). Map the dashboard fields to these sensors:

Energy dashboard field Sensor
Grid consumption (electricity grid → consumed from grid) grid_bought_total
Return to grid (electricity grid → returned to grid) grid_fed_in_total
Solar production pv_energy_total
Battery systemsenergy going in to the battery battery_charge_total
Battery systemsenergy coming out of the battery battery_discharge_total

The battery and solar fields use the lifetime *_total sensors — the Energy dashboard buckets them into hours/days itself. The grid sensors (grid_bought_total / grid_fed_in_total) are the device's own daily counters that reset at local midnight; that's still fine here — the Energy dashboard's total_increasing handling detects the daily reset and keeps the running total correct. The derived daily battery_charge_energy / battery_discharge_energy sensors are for cards and automations, not this dashboard.

Have an external CHINT meter? meter_fwd_energy_total / meter_rev_energy_total are lifetime grid totals and can be used for the grid fields instead of the daily device counters. Which one is consumption vs return depends on your meter's CT orientation — verify against a live import/export before committing the mapping.

When you add the battery, HA also offers an optional Type of power measurement step for live monitoring. Choose Standard and set:

Power-measurement field Sensor
Battery power battery_power
Battery state of charge soc

battery_power is signed + discharging / − charging, which is exactly HA's Standard polarity (positive = discharge, negative = charge) — leave it on Standard, not Inverted. These two are optional; the kWh in/out totals above are what actually drive the dashboard.

No PV / AC-coupled solar? If your X1 doesn't measure PV (the PV connected option is off, or your panels feed the grid through a separate AC-coupled inverter), leave Solar production unset here and add that inverter as its own solar source — pv_energy_total would otherwise read 0 (or a phantom value; see Troubleshooting).

Control

The X1 only obeys external power commands once it's handed to Modbus, so control is a two-step sequence the integration performs for you:

  • Modbus Control ON → work mode 10064 = 3 (VPP/3rd-party), which unlocks the setpoint.
  • Battery Setpoint → writes signed watts to 10071: negative = charge, positive = discharge, 0 = idle. Only honored while Modbus Control is ON. Clamped to the inverter's live charge/discharge limits (reg 10036/10038), which default to −6 kW / +6.6 kW when a limit read is missing.
  • Modbus Control OFF → writes 10071 = 0 then 10064 = 20, returning control to the Anker app.

Selecting VPP/3rd-party on the Work Mode select is equivalent to turning Modbus Control ON; any other mode hands the battery back to that mode's logic.

Watchdog: the inverter has a comms watchdog (register 10080) that reverts it to self-consumption if the Modbus master goes quiet — a dead-man's switch, so a crash or removal can't leave the battery stuck on a stale command. HA's 1 s polling keeps the link alive.

At very low SOC the BMS sits in Standby and won't discharge regardless of command.

Derived metrics

  • charge_power / discharge_power — the signed battery_power split into two unsigned sensors (handy for the Energy dashboard and automations).
  • battery_charge_energy / battery_discharge_energy — true daily energy. The device's own "daily" registers don't reset on this firmware, so these are derived from the lifetime totals and reset at local midnight (the baseline is persisted across restarts and re-based if HA was off over midnight).
  • pv_power vs usable_pv_powerpv_power is the gross sum of the two DC strings (V × I per string). usable_pv_power is the inverter's own post-MPPT harvested total (reg 10183); it reads lower than the gross sum at low irradiance and is the steadier, more authoritative figure.
  • inverter_loss — DC↔AC conversion loss + the converter's own draw, computed from the power balance total_pv + battery_power − ac_active_power, where total_pv folds in the inverter's PV registers (native PV plus any externally-metered 3rd-party PV — internal quantities, not their own sensors). PV and the battery share one PCS, so ac_active_power already carries the PV contribution. Floored at 0 to absorb measurement noise. The formula is topology-aware:
    • DC-coupled (PV connected): loss is only observable on discharge (~10% conversion loss, validated against logged data); the registers don't expose the charge/idle loss, so it reports 0 while charging or idle.
    • AC-coupled (PV connected off): the same balance, plus an SoC- calibrated charge-power correction (this firmware under-reports charge power on that topology), and forced to 0 in Standby/Sleep where the converter is idle. On AC-coupled sites the figure is an upper bound — a neighbouring AC-coupled solar inverter's export can poison the balance.

Important: one Modbus client at a time

The X1 accepts only one Modbus TCP connection at a time. While this integration is running, don't point other Modbus clients (the YAML modbus: integration, the tools/ scripts, a second Node-RED Modbus node) at the same device — drive control by calling this integration's entities/services instead.

Calibration notes (for the curious)

  • The little-word-first decode helpers apply only to the native Anker register bank (10000–11134): 32-bit registers use little-endian word order (low word first) and strings are low-byte-first within each register. The embedded SunSpec bank (10698+ / 40000+) uses the opposite, standard big-word-first order and is not touched by this integration.
  • Gains: voltage ÷10, current ÷100, frequency ÷100, temperature ÷10. All energy accumulators are ÷100 on this firmware (PV, battery charge/discharge, and grid bought/fed-in) — the official spec's "gain 10" column is wrong for the energy registers (ground-truthed 2026-07-09: raw 666 = 6.66 kWh).
  • battery_nominal_capacity is battery_module_count (reg 10249) × 5 kWh, the per-module size of every Anker SOLIX X1 pack.
  • pymodbus renamed the per-call slave= kwarg to device_id= in 3.10; the integration detects which one the installed version uses at runtime.

Options

After installation you can reconfigure the integration via Settings → Devices & Services → Anker SOLIX X1 → Configure:

Option Default Notes
Poll interval (seconds) 1 How often to query the inverter over Modbus TCP (1–600 s).
PV connected On Turn off if your X1 has no DC PV strings attached. Some firmware builds misattribute grid overflow to the PV registers (phantom solar), and the per-string registers hold garbage. When disabled, pv_power, usable_pv_power, pv1_power, pv2_power, pv_energy_today, and pv_energy_total are forced to 0; the sensor entities stay visible, and the loss/charge math switches to the AC-coupled branch.

Troubleshooting

  • "Failed to connect over Modbus TCP" — confirm Modbus TCP is enabled in the Professional app, the IP/port are right, and nothing else holds the single Modbus connection (stop the tools/ scripts; remove any YAML modbus: hub pointed at the X1).
  • PV reads a phantom value — on some units the device populates the PV registers even with no/undetected strings (grid overflow misattributed as PV). Disable the PV connected option (Settings → Configure) to pin all PV-derived sensors to 0. This also keeps inverter_loss honest: the loss balance includes PV, so pinning it to 0 stops the phantom value from leaking into the loss figure.
  • meter_* sensors are unavailable — expected unless an external CHINT 3-phase meter is wired to the X1 and communicating (meter_comm_status = Normal).
  • battery_pack_voltage is unavailable — some units don't implement register 10253; the rest of the poll is unaffected.

tools/

Standalone, dependency-free Python diagnostics used to build this: scan.py (register sweep), dashboard.py (live readout), decode.py (register decode helpers), charge_test.py (safe write test), x1_control.py (discharge-on-need loop), and anker_sampler.py + sampler_watchdog.sh (a long-running CSV telemetry sampler for HAOS).

Disclaimer

Not affiliated with or endorsed by Anker. Writing to undocumented registers controls real hardware — use at your own risk. The author accepts no liability for damage or lost energy.

License

MIT

About

Local Modbus TCP Home Assistant integration for the Anker SOLIX X1 hybrid inverter/battery (no cloud).

Topics

Resources

Stars

10 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages