Documented the known_inverters metadata field across device support docs/templates so contributors can record which inverter models have been validated per devcode.
Device support for devcode 2361 (SRNE SR-EOV24-3.5K-5KWh) with sensor mappings and operating mode normalization (thanks to @pjJedi for the CLI analysis data).
Additional sensor definitions (inverter current, load apparent power, PV/inverter radiator temperatures, battery energy charge/discharge counters, accumulated mains load energy, daily/total battery amp-hours, etc.) so devcode-specific mappings can surface the extended telemetry in Home Assistant.
CLI analyze command now pulls control-field metadata and live parameter values so contributors can map diagnostics/configuration sensors without manually querying the API.
Changed
README device-support section now explicitly lists the confirmed inverter pairing for devcodes 2376 (POW-HVM6.2K-48V-LIP) and 6422 (Must PH19-6048 EXP) and clarifies how the generic fallback behaves.
DessMonitor API and config flow now mask usernames, passwords, and tokens in logs and drop unused RC4 helper to avoid leaking sensitive data.
Sensor setup now applies devcode transformations before filtering supported types, preventing SRNE/POW-HVM data from being dropped when titles differ from the canonical names.
Fixed
devcode 2361 operating mode mapping now handles the "Inverter Operation" string reported by SRNE SR-EOV24 collectors so the mode appears in Home Assistant (#3).
Battery Energy Total (Charge/Discharge) sensors use the measurement state class to avoid Home Assistant Recorder warnings when devices report occasional counter decreases (#3).