Appliance:2REF11EIDA__4

Andrzej Szombierski edited this page Mar 22, 2026 · 6 revisions

Brand name: Standard-Depth 4-Door French Door Refrigerator
Official model name: LF29H8330S
ThinQ Model ID: 2REF11EIDA__4 Platform: Thinq2

This is a fridge/freezer, with a flex temp drawer, in door water/ice maker, and a freezer ice maker.

It communicates with the "AABB" protocol.

Common structures

Status block

Several packets contain a 68-byte block describing the appliance's state.

The following bytes have been identified

byte index
(zero-based)
field description
1 fridge temp setpoint Formula = 44 - value (in decimal). E.g. if value is 10, then setpoint is 34 °F
2 freezer temp setpoint Formula: 6 - value (in decimal, for °F). E.g. if value is 12, then setpoint is -6 °F
3 Ice Plus command 1 = off, 2 = on
5 Smart grid command 0 = off, 2 = on
What's 1 then? Power reduced by grid command?
7 Door status 1 = open, 0 = closed
No differentiation between each of the 4 doors/drawers. Set to 1 if any door is open.
8 temperature unit 0=fahrenheit 1=celsius
10 Panel lock command 1=unlocked, 2=locked
13 Flex drawer setpoint Values: 1 - chilled wine. 2 - deli/snacks. 3 - cold drink. 4 - meat/seafood. 5 - freezer
32 In-door ice command 0 = off, 1 = on, 2 = ice full
33 Cubed Ice command
(freezer drawer ice maker)
0 = off, 1 = on, 2 = ice full

(thanks to @jseyfert3 for the analysis)

Packet format

The packets below are described excluding the AA..BB framing. This means that each full packet is 4 bytes longer.

device-to-cloud messages

"10EB" message

This message contains the initial state of the fridge. It consists of a 2-byte header 10EB followed by a 68-byte status block.

Example (whitespace added for clarity):

10EB 0209060202020400000001FFFF0300FFFF00FFFFFFFFFFFFFF020001010100000102FF6161FFFFFF01FF00FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF0078FF0000

"10EC" message

This message notifies of a change in the fridge's state. It consists of a 2-byte header 10EC followed by two copies of the status block. The first copy describes the previous state, the second one - the new state.

Example (whitespace added for clarity):

10EC 0209060202020400000001FFFF0300FFFF00FFFFFFFFFFFFFF020001010100000102FF6161FFFFFF01FF00FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF0078FF0000
     0209060202020401000001FFFF0300FFFF00FFFFFFFFFFFFFF020001010100000102FF6161FFFFFF01FF00FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF0078FF0000

cloud-to-device messages

initial query

The following message needs to be sent before the fridge will produce any useful output:

F0ED1211010000010400

change settings

All the settings appear to be settable with a single complex message.

F017FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF000000FFFF00FFFFFFFF00FFFFFFFFFFFFFFFFFF00FFFFFF1EFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF0AFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF

Skipping the F017 header, the following bytes have been identified, matching the status block precisely.

byte index
(zero-based)
field description
1 fridge temp setpoint same as in the status block
2 freezer temp setpoint same as in the status block
13 Flex drawer setpoint same as in the status block

Setting any of these bytes to 0xff means "leave unchanged".