Notes from bringing up a current-gen LG appliance — an BDH_D30007_US dryer (DeviceType 202, RTK_RTL8720cm Wi-Fi/"CLIP" module, protocolVer 4.9, sw 2.11.263) — fully local on rethink. It now completes SoftAP → /route → cert → MQTT clip, enrolls, and streams telemetry with no LG cloud contact. A couple of things differ from older firmware; this documents them so the next person with a newer module doesn't repeat the rabbit holes.

1. The setup publicKey must have no in-band whitespace (fixed in this branch)

rethink-setup's hardcoded publicKey was a tab-indented template literal, so every base64 line carried a leading \t inside the PEM. Older firmware strips it; the RTL8720cm CLIP parser is strict.

With the indentation, getDeviceInfo comes back as:

encrypt_val: ''
extra: 'POWER_ON|...|encryptRes:ffff'   # the device's RSA-encrypt step failed

The device then can't build a cert request, reboots onto Wi-Fi, polls /route a few times, sends a clean close_notify, and gives up — which looks like a /route problem but is really the setup key.

With a clean PEM (base64 at column 0, same key bytes):

extra: 'POWER_ON|...|encryptRes:0'
encrypt_val: 'frkUhxnfo4kzwExk1zF2...'   # non-empty

…and it proceeds straight through /routeGET /route/certificatePOST /device/:id/certificate → MQTT. See the rethink-setup: strip whitespace from the setup publicKey commit.

2. Unknown models now loosely enroll instead of being dropped (added in this branch)

Previously an unknown modelId was dropped (ha_bridge logged device type ... unknown and returned). A new appliance could provision perfectly and still never appear in HA, get no answer from the cloud side, and leave you with no captured data to build a class from. A generic raw-capture fallback now enrolls any unknown thinq2 device and republishes its raw packet hex to a diagnostic HA sensor, so adding real support becomes a decode exercise against live data. See the ha_bridge: generic raw-capture fallback commit + cloud/devices/generic.ts.

3. Legacy TLS profile (modern Node / OpenSSL 3) (not changed here — see issues #17/#18)

This firmware is TLS-1.2-only and prefers legacy ECDHE-CBC-SHA suites. On Node ≥ 20 / OpenSSL 3 the server defaults are too strict and the handshake fails. A relaxed profile is needed: minVersion/maxVersion: 'TLSv1.2', the legacy ciphers at @SECLEVEL=0, and SSL_OP_ALLOW_UNSAFE_LEGACY_RENEGOTIATION | SSL_OP_LEGACY_SERVER_CONNECT on the HTTPS and MQTTS servers. This is already tracked in issues #17/#18; left out of this PR to keep it focused, but required to reproduce the flow on a current Node.

4. Post-provision: power-cycle the appliance once

After releaseDev the device reboots itself, but on this firmware it then sits in "connecting…", streams monitoring for a few minutes, and publishes clip/provisioning/.../undeploy (we see req_timesync with rssi:-100 = a reboot) — a re-registration loop that never settles. A hard power-cycle of the appliance after provisioning makes it come up clean and hold a stable connection (verified across a full ~50-minute dryer cycle: one MQTT connection, 0 undeploys, ~960 telemetry packets). The firmware's own soft-reset appears insufficient where a cold boot is not. Whether a cloud/setup-triggerable clean reset exists (a reboot opcode after releaseDev, or an AABB reboot command over MQTT) is an open question.

Things that were NOT the problem (so nobody chases them)

  • The fake OTP / shared publicKey. Fine for the local flow: rethink signs the CSR without verifying the ciphertext, and the publicKey is a fixed value (a real cloud-issued key is byte-identical to the one in the repo). A self-generated base64(uuid) OTP also works.
  • The minimal /route body. Upstream returns ssl://<config.hostname>:<port>, which the rethink CA cert covers, so the broker TLS validates fine. (Returning a real per-region AWS mqtt host would break it — the device validates the broker cert against that SNI and rejects it bad_certificate.)
  • svcphase. Our working setup ran svcphase: 'OP' rather than the repo's debug-UART 'QA'; we could not isolate whether OP is required for this firmware, so we left the default alone here. Flagging in case it matters for other newer modules.

Device under test

BDH_D30007_US, did fe8b2ea0-…-3034dbd055fe. Full packet captures + decrypted MQTT clip transcripts available (SoftAP setup, /route, cert, deploy/completeProvisioning/_ack, telemetry).