0.1.9
Version 0.1.9
Enhanced Register Coverage & Entity Organization
New Function Controls
-
Added Dry Contactor Multiplex Control: New select entity for configuring dry contactor multiplex modes with proper options:
- 0: null
- 1: RSD
- 2: Dark Start
- 3: Smart load
- 4: Non-critical Load
-
Added External CT Position Control: New 2-bit select entity for configuring external CT position:
- 0: Grid to User
- 1: Inverter Grid Port
-
Added 7-Day Working Mode Switch: New switch for controlling 7-day period work mode selection
-
Added Over Frequency Stop Switch: New switch for controlling over frequency stop function activation
Register Documentation & Code Quality Improvements
-
Complete Register Documentation: Added comprehensive unit and range information for all INPUT and HOLD registers that were previously missing documentation
-
Fixed Register Sequence Gaps: Added proper documentation for undefined register gaps to maintain sequence integrity
-
Register Definition Cleanup:
- Removed duplicate register 77 definition
- Fixed register 161 contradiction documentation
- Resolved register 232/233 bit assignments
-
Enhanced Entity Organization: Improved switch_types.py with better register number comments and clearer organization by register groups
New Power Control
- Added Grid Peak Shaving Power 1: New number entity for setting Grid Peak Shaving Power 1 value (0-65,535W) - register 232 is now properly utilized
Technical Improvements
-
Enhanced Bit Field Controls: Complete coverage of H_FUNCTION_ENABLE_5 register (233) with proper switch and select entities for all bits:
- Bits 0-3, 10: Switch entities
- Bits 4-7: Dry Contactor Multiplex select entity
- Bits 8-9: External CT Position select entity
-
Improved Register Constants: Updated register naming for better clarity and consistency
Upgrading from 0.1.8
This update is fully compatible with existing configurations. After upgrading, you'll have access to:
- New dry contactor multiplex configuration options
- External CT position controls
- Additional working mode and frequency stop controls
- Grid peak shaving power setting