Skip to content

Releases: bditter/HA-Hidratespark

HA Hidratespark v1.2.6-beta.6

Pre-release

Choose a tag to compare

@bditter bditter released this 23 Jul 20:23

What's new in v1.2.6-beta.6

Added

  • Added disabled-by-default diagnostics for calibrated empty raw weight, full raw weight, active raw-units-per-mL scale, and refill detector armed state.

HA Hidratespark v1.2.6-beta.5

Pre-release

Choose a tag to compare

@bditter bditter released this 23 Jul 20:21

What's new in v1.2.6-beta.5

Fixed

  • Refill counting now re-arms as soon as calibrated weight falls to the low threshold and counts a refill when the mug returns to the fill line, avoiding missed refills after empty-to-fill-line cycles.

HA Hidratespark v1.2.6-beta.4

Pre-release

Choose a tag to compare

@bditter bditter released this 23 Jul 17:24

What's new in v1.2.6-beta.4

Fixed

  • Current fill now snaps to zero when a calibrated raw weight is within 5 mL of the empty anchor, preventing tiny near-empty residuals like 0.07 fl oz.

HA Hidratespark v1.2.6-beta.3

Pre-release

Choose a tag to compare

@bditter bditter released this 23 Jul 13:26

What's new in v1.2.6-beta.3

Fixed

  • Reset totals now re-baselines current fill from the latest calibrated raw weight, preventing an immediate partial fill from being counted as consumed.
  • Weight-based refill counting now requires a low-to-near-full transition, so a fill that climbs in multiple stable weight steps counts as one refill.

HA Hidratespark v1.2.6-beta.2

Pre-release

Choose a tag to compare

@bditter bditter released this 23 Jul 13:02

What's new in v1.2.6-beta.2

Changed

  • When explicit full/empty calibration exists, water totals are now counted from calibrated weight drops instead of raw sip-percent volume.
  • Partial fills now continue to use their raw position in the calibrated full/empty span, so near-full readings can show 99% instead of snapping to 100%.

HA Hidratespark v1.2.6-beta.1

Pre-release

Choose a tag to compare

@bditter bditter released this 22 Jul 16:13

What's new in v1.2.6-beta.1

Added

  • Added disabled-by-default diagnostic sensors for the raw sip percent and raw reported total fields sent by the bottle.

Changed

  • Sip totals are back to using the bottle's raw percent-derived sip volume while the reported-total field is investigated.

HA Hidratespark v1.2.5

Choose a tag to compare

@bditter bditter released this 22 Jul 15:14

What's new in v1.2.5

Fixed

  • Current fill now ignores tiny weight-derived changes under 5 mL so raw sensor jitter does not show up as constant 0.03-0.08 fl oz movement.
  • Volume sensors now publish native two-decimal fluid ounces so the default Home Assistant state is 0.00 rather than 0.000.

HA Hidratespark v1.2.4

Choose a tag to compare

@bditter bditter released this 22 Jul 14:46

What's new in v1.2.4

Fixed

  • Sip totals now use the bottle's cumulative reported mL delta when available, reducing undercount caused by integer percent-based sip volume frames.
  • Volume sensors now suggest two decimal places in Home Assistant so fill values like 887 mL display as 29.99 fl oz instead of rounding to 30.0 fl oz.

HA Hidratespark v1.2.3

Choose a tag to compare

@bditter bditter released this 20 Jul 17:55

What's new in v1.2.3

Added

  • Added a Last update time sensor that records when bottle data was most recently received by the integration.

HA Hidratespark v1.2.2

Choose a tag to compare

@bditter bditter released this 20 Jul 17:23

What's new in v1.2.2

Added

  • Read the standard BLE serial number characteristic when available, expose it as a regular sensor, and use it as the Home Assistant device display name.
  • Added a Reset totals button to clear accumulated water, sip, refill, and lifetime totals without clearing calibration or current fill.