200bb99

Changed

  • Layering cleanup LC-3 — alert, throttle, and session-energy analytics moved
    out of the TUI widget into L2 (actop.analytics). New AlertEngine owns the
    per-alert sustain counters, swap-rise window, and cumulative energy integral;
    AlertEngine.feed(snapshot) returns an AlertFrame (thermal/throttle/bw/pkg/
    swap verdicts + swap_rise_gb + session_energy_j). domain_throttling,
    bandwidth_percent, and package_power_percent are now module-level L2
    functions taking explicit reference values. The dashboard widget's
    _compute_alerts shrank to formatting the frame into status-line tokens; no
    alert/throttle/energy math remains in tui/. No visual change.
  • Session energy is now integrated over the real inter-frame dt derived from
    SystemSnapshot.timestamp instead of the fixed sample interval. This is a
    correctness improvement (honest elapsed time), with one behavior note: the
    first frame contributes 0 J (no prior timestamp to diff against), whereas
    the old fixed-interval integral counted the first frame.