Battery System Setup

Tesla Powerwall

PowerSync supports two methods for accessing your Tesla Powerwall. Choose one — you don't need both.

Option 1: Teslemetry (Recommended - ~$4/month)

The easiest setup option. Teslemetry is a third-party proxy service for Tesla API.

Pros
Simple API key authentication No OAuth complexity
Works with localhost No public domain needed
2-minute setup Just copy/paste API key
Reliable service Well-maintained proxy

Setup:

  1. Sign up at https://teslemetry.com
  2. Connect your Tesla account
  3. Copy your API key
  4. Paste into PowerSync settings

Option 2: Tesla Fleet API (Free)

Direct OAuth access to Tesla's Fleet API. Completely free but requires more setup.

Setup:

  1. Install the official Tesla Fleet integration in Home Assistant
    • Settings > Devices & Services > Add Integration > "Tesla Fleet"
    • Follow the OAuth login flow
  2. PowerSync automatically detects your Tesla Fleet credentials
  3. Leave the Teslemetry field empty during PowerSync setup

FoxESS

Supports H1, H3, H3-Pro, H3 Smart, and KH model families via Modbus TCP or RS485 serial. No cloud API required for battery control — all control is done locally via Modbus.

OEM rebrands using identical hardware are also supported — the model family is auto-detected via register probing during setup.

Supported Models

Model Family Type Register Space OEM Rebrands
H1 Single Phase 31xxx/41xxx AIO-H1, a-TroniX AX
H3 Three Phase 31xxx/41xxx AIO-H3, Kuara H3, Sonnenkraft SK-HWR, 1KOMMA5
H3-Pro Three Phase (Higher Power) 37xxx/46xxx/49xxx
H3 Smart Three Phase (Native WiFi) 37xxx/46xxx/49xxx
KH Single Phase Hybrid 31xxx/41xxx

Rebrands: If your inverter is an OEM rebrand (e.g., Kuara, Sonnenkraft, 1KOMMA5), just connect it like any other FoxESS unit. PowerSync identifies the model family automatically from Modbus registers — no special configuration needed.

Connection Options

Modbus TCP (Recommended for H3 Smart)

  • Port: 502 (default)
  • Slave ID: 247 (default)
  • For H3 Smart: Connect directly to the inverter's IP address — no external adapter needed

RS485 Serial

  • Baud rate: 9600 (default)
  • Slave ID: 247 (default)
  • Requires an RS485 adapter (USB or network gateway like Elfin EW11)

H3 Smart Setup

The H3 Smart has a built-in WiFi Modbus TCP server. No external RS485 adapter is needed.

  1. Find the inverter's IP address — it appears as "espressif" on your network (it uses an ESP WiFi module)
  2. Ensure firmware is up to date — the Modbus TCP server requires current firmware
  3. Use default settings — Port 502, Slave ID 247
  4. PowerSync will auto-detect the model as H3 Smart during setup

Troubleshooting: If the connection test fails:

  • Check your router for a device named "espressif" to find the correct IP
  • Update inverter firmware to the latest version
  • Verify port 502 is not blocked by your network

FoxESS Cloud (Optional)

A FoxESS Cloud API key allows PowerSync to sync Amber/Octopus prices as time-based schedules on your inverter (up to 8 periods per day). This is not required for battery control — all control is done locally via Modbus.

Getting your API key:

  1. Log in to foxesscloud.com
  2. Go to User Profile > API Management
  3. Generate a new API key
  4. Enter the API key and your device serial number during PowerSync setup

Note: When Smart Optimization (LP) is enabled, cloud schedule sync is automatically skipped — the LP optimizer controls the inverter directly via Modbus, and uploading schedules to the cloud would conflict.

Work Modes

Mode Value Description
Self Use 0 Default operation
Feed-in First 1 Export priority
Backup 2 Backup mode
Force Charge 3 Force charge from grid
Force Discharge 4 Force discharge/export

Sigenergy

Full support for Sigenergy hybrid inverters with integrated battery storage.

Features

  • Tariff Sync via Cloud API — Uploads pricing to Sigenergy Cloud using 30-minute TOU format
  • Real-Time Energy Data via Modbus — Reads solar, battery, grid power and SOC from your inverter
  • DC Solar Curtailment — Controls DC solar via Modbus TCP during negative prices (load-following mode)

Connection Requirements

Connection Purpose Required
Cloud API Tariff sync to Sigenergy Yes
Modbus TCP Real-time energy data + DC curtailment Yes

Important: Modbus TCP Server must be enabled on your Sigenergy inverter before PowerSync can connect. This setting is typically configured by your installer via the SigenStor app or installer portal.

Device ID Note: If you have an AC Charger installed, it uses Device ID 1 by default. The inverter must be set to a higher ID (e.g., 2).

Getting Cloud API Credentials

What You Need:

Credential Description Where to Find
Email Your Sigenergy account email Your login email
Password Your Sigenergy account password Your normal password
Device ID Optional — usually not needed Leave blank (see note below)
Station ID Your Sigenergy station identifier SigenAI or browser dev tools

Device ID (optional):

Sigenergy no longer requires a Device ID for authentication. Leave this field blank. If authentication fails without it, you can find it by:

  1. Go to https://web-aus.sigencloud.com/ in your browser (don't log in yet)
  2. Open Developer Tools (F12) > Network tab > filter by Fetch/XHR > check "Preserve log"
  3. Log in normally
  4. Find the token POST request > Payload tab > look for userDeviceId (13 digits)

Getting Station ID:

  • Ask SigenAI in the app: "Tell me my StationID"
  • Or find it in dev tools network requests

Sigenergy Configuration

  1. Select Sigenergy as your battery system
  2. Enter Cloud credentials (email, password)
  3. Select your station from the list
  4. Enter your inverter's Modbus IP address
  5. Optionally enable DC solar curtailment

Sungrow SH-series

Full support for Sungrow SH-series hybrid inverters via direct Modbus TCP. No cloud API required.

Features

  • Direct Modbus Control — All control via local Modbus TCP
  • Force Charge/Discharge — Manual or automatic battery control
  • Rate Limiting — Set maximum charge and discharge rates (kW)
  • Export Limit Control — Limit grid export power
  • Backup Reserve — Configure minimum SOC for backup power
  • Battery Health Monitoring — Read SOH directly from BMS
  • AEMO Spike Auto-Discharge — Automatic VPP participation for Globird users

Supported Models

Series Type Battery Control
SH-series Hybrid Inverter Full support
SG-series String Inverter AC curtailment only (no battery)

Connection Settings

Setting Default
Port 502
Slave ID 1

Modbus Registers

Register Function
13021 Battery SOC (0.1%)
13022 Battery SOH (0.1%)
13050 EMS Mode (0=Self-consumption, 2=Forced)
13051 Charge Command (0xAA=Charge, 0xBB=Discharge, 0xCC=Stop)
13059 Minimum SOC / Backup Reserve (0.1%)
13066 Max Discharge Current (0.001A)
13067 Max Charge Current (0.001A)
13074 Export Power Limit (W)

Sungrow with Globird VPP

Globird's VPP program pays premium rates during AEMO price spikes ($3000/MWh or above). PowerSync can automatically participate:

  1. Enable AEMO Spike Auto-Discharge in the mobile app Controls screen
  2. Select your NEM region (NSW1, VIC1, QLD1, SA1, TAS1)
  3. When AEMO prices hit $3000/MWh, PowerSync automatically forces battery discharge
  4. When the spike ends, battery returns to normal operation
  5. Push notifications are sent for both spike start and end

Tip: If you also have a separate AC-coupled solar inverter, configure it in the AC Inverter Curtailment section. PowerSync will validate that your Sungrow battery and AC inverter don't use the same Modbus slave ID.