Summary

This release updates the polarization workflow around PPL/XPL, adds a reusable polarizer calibration baseline, and sets validated default acquisition exposures for routine PPL/XPL imaging.

Added

  • Polarization mode naming is now standardized to PPL / XPL across the app, sequence flow, and documentation.
  • Polarizer-angle calibration now performs a coarse scan plus a fine scan around the darkest XPL angle.
  • Calibrated polarizer baseline values are saved and restored on later app launches.
  • Reachable orthogonal-angle handling for PPL derivation from the calibrated XPL angle.
  • scripts/analyze_xpl_exposure_sweep.py for reviewing RAW16 XPL exposure-sweep datasets.
  • Release packaging now stages files before zipping to avoid transient file-lock failures during archive creation.

Changed

  • Default validated acquisition baseline:
    • PPL: 18000 us at polarizer 5 deg
    • XPL: 400000 us at polarizer 95 deg
  • Default polarizer calibration exposure:
    • 200000 us
  • PPL is no longer chosen from a brightness search; it is derived from the reachable orthogonal angle relative to XPL.
  • Sequence output folders now use ppl and xpl.
  • Distribution and implementation docs now match the current PPL/XPL baseline and calibration flow.

Sequence Behavior

  • Live camera preview is paused before sequence capture and restored afterward.
  • Sequence capture remains XI_RAW16 only.
  • Sequence images are saved as Bayer RAW uint16 TIFF.
  • Sequence outputs include:
    • {SampleID}_log.csv
    • {SampleID}_metadata.json
  • CSV logs now include calibration signal metrics used during XPL-angle selection.

Polarizer Calibration

  • The calibration scan searches for the darkest XPL angle first.
  • A coarse scan identifies the minimum region, then a fine scan refines the result around that angle.
  • PPL is assigned as XPL + 90 deg or XPL - 90 deg, whichever stays inside the reachable polarizer range.
  • The resulting baseline is saved for reuse on later runs.

Conversion Tool

  • Converts saved RAW16 TIFF datasets into RGB preview images.
  • Processes the selected folder and its immediate child folders.
  • Saves results into a sibling _rgb folder.
  • Uses demosaic plus fixed white balance plus gamma for preview generation.

Validation

  • python -m py_compile apis\\config.py apis\\io.py apis\\sequence.py apis\\utils.py app\\main.py app\\workers.py scripts\\analyze_xpl_exposure_sweep.py tests\\test_ximea_raw16_sequence.py
  • python -m unittest tests.test_ximea_raw16_sequence tests.test_mock_serial
  • .\build\build.ps1 -Version 0.1.3

Notes

  • Sequence capture is still RAW16-only in this release.
  • Live view and Snapshot behavior are unchanged.
  • Reusing the same SampleID may append to the existing CSV log.