Skip to content

Repository files navigation

PRIMED-AI

EchoJEPA + HuBERT-ECG: frozen-embedding, deployment-risk study of multimodal LVEF estimation

criticaldata/PRIMED-AI


Overview

PRIMED-AI studies whether fusing two cardiac foundation models — EchoJEPA-L (echocardiogram video) and HuBERT-ECG (12-lead ECG) — can estimate left ventricular ejection fraction (LVEF) in a way that is ready for real-world deployment, not just benchmark accuracy.

The pipeline uses frozen embeddings only: foundation models act as fixed feature extractors; all task-specific learning happens in lightweight probes on top of cached representations.

ECG is ubiquitous and cheap; echo requires a sonographer and a cart. If we train a fused model but only ECG is available at inference, how much accuracy do we lose — and does the model degrade gracefully or fail silently?


Motivation

LVEF is a core measure of heart pump function, used to diagnose heart failure and guide treatment. Echocardiography is accurate but resource-intensive; ECG is cheap, fast, and available almost everywhere.

Most multimodal ML papers ask whether fusion beats unimodal baselines on a leaderboard. This project asks the deployment-and-risk questions instead:

Question What we evaluate
Does it work? Missing-modality robustness when echo or ECG is unavailable at inference
Is it equitable? Fairness audit of EF error across sex, age, and race
Is it safe? Whether accuracy degrades gracefully or fails silently under shift

Fusion vs. unimodal accuracy is supporting evidence, not the thesis.


Pipeline

Stage Input Output
Cohort construction MIMIC-IV-Echo studies, MIMIC-IV-ECG records, MIMIC-IV demographics Paired rows on subject_id within 24–48h, joined to structured LVEF, split by subject
Embedding extraction Paired cohort only (~few K–tens of K studies, not all 525K echos) Frozen EchoJEPA-L (1024-d) and HuBERT-ECG (768-d) vectors, cached to Parquet
Probes Cached embeddings ECG-only, echo-only (attentive), concat-MLP, and cross-attention fusion heads
Deployment analyses Trained fused checkpoint + held-out test split Missing-modality degradation, fairness stratification, optional calibration

Expensive forward passes run once and are cached; probe training reads only from cache and completes in minutes. Foundation-model weights are never fine-tuned.

See TECHNICAL.md for full pipeline details.


Results

Held-out test split, n = 245. One fused cross-attention checkpoint (M09) trained on both modalities, scored under three inference-time conditions — no separate unimodal models are trained for the dropped conditions.

Condition Inference input LVEF MAE EF≤40% AUROC
full Echo + ECG present 10.28 0.766
ecg_dropped ECG branch masked, echo present 15.13 0.750
echo_dropped Echo branch masked, ECG present 18.57 0.693

Dropping echo costs more than dropping ECG on both metrics. AUROC holds up better than MAE under either drop, which is the graceful-degradation pattern rather than silent failure.

Provenance: real run on cached EchoJEPA (vjepa2.1-vitl-mimic-pt-100) + HuBERT-ECG embeddings, point estimates transcribed from the E02 evaluation into results/missing_modality.json. Bootstrap confidence intervals need per-example predictions and are pending a canonical rerun. results/ is gitignored, so that JSON is not in this repository — see CONTRIBUTING.md for what reproducing these numbers takes.

Reproduce with:

python scripts/evaluate_missing_modality.py

Defaults assume the standard cohort/embedding/checkpoint layout; --help lists the paths. --embed-dim, --echo-dim, and --ecg-dim must match the checkpoint architecture or the state_dict load fails on shape.


Models & data

Component Source
EchoJEPA-L Video JEPA for echo · arXiv:2602.02603 · bowang-lab/EchoJEPA
Echo embeddings Pre-extracted, all 6 checkpoint variants · MITCriticalData/mimic-iv-echo-jepa-embeddings (gated)
HuBERT-ECG Self-supervised 12-lead ECG model · Edoardo-BS/hubert-ecg-baseproduced the reported ECG embeddings
ECG-FM Alternative ECG foundation model · arXiv:2408.05178 · wanglab/ecg-fm — wrapper shipped, not used for reported results
MIMIC-IV-Echo 0.1 Echo DICOM + structured LVEF · PhysioNet
MIMIC-IV-ECG 1.0 12-lead waveforms · PhysioNet
MIMIC-IV 3.1 Demographics for fairness audit · PhysioNet

All MIMIC datasets and the embedding dataset require PhysioNet credentialing and signed Data Use Agreements. docs/embeddings.md covers loading and re-extraction.

Which ECG encoder? The reported results use pre-extracted HuBERT-ECG embeddings. The repo also ships a frozen ECG-FM wrapper (encoders/ecg_fm.py, scripts/extract_ecg_embeddings.py) as an alternative extraction path — it is implemented and unit-tested but did not produce any reported number.

Scope: Task A — continuous LVEF regression + EF≤40% binary clinical gate (HFrEF threshold). Valvular disease and HFpEF phenotyping are out of scope.


Metrics

Metric Purpose
LVEF MAE Continuous regression quality
EF≤40% AUROC Clinical gate for reduced ejection fraction
Missing-modality degradation Δ MAE / Δ AUROC when echo or ECG is dropped at inference
Fairness gap Per-stratum error across sex, age band, and race

Repository guide

Document Contents
TECHNICAL.md Pipeline architecture, probes, deployment analyses, expected artifacts
docs/embeddings.md Embedding sources, loading code, model registry, re-extraction
CONTRIBUTING.md Local setup, tests, linting, data access, reproducibility

Open work lives on the issue tracker.


Status

The work pivoted from a fusion benchmark to a model-agnostic modality-failure analysis framework — failure taxonomy, complementarity matrix, and loud-vs-silent dropout profile. That framework is the main contribution and lives in src/primed_ai/failure/; the fusion pipeline described above is the substrate it is instantiated on.

Still open: PhysioNet credentialing and reserved GPU/storage, both needed for the canonical real-data rerun.


Related work

Work Relationship
EchoJEPA Echo foundation model used in this pipeline
HuBERT-ECG ECG foundation model behind the reported ECG embeddings
ECG-FM Alternative ECG foundation model — wrapper shipped, not used for reported results
EchoingECG Closest prior cross-modal echo+ECG work — differentiated on frozen-embedding fusion + deployment-risk framing

Citation

If you use this work, please cite the repository:

@misc{primedai2026,
  title        = {PRIMED-AI: Deployment-Risk Study of Multimodal LVEF Estimation with EchoJEPA and HuBERT-ECG},
  author       = {Critical Data},
  year         = {2026},
  howpublished = {\url{https://github.com/criticaldata/PRIMED-AI}}
}

License

MIT — see LICENSE.

scripts/embedding_extraction/src/ is vendored V-JEPA code from Meta Platforms and stays under its own MIT license (see scripts/embedding_extraction/src/LICENSE).