1. Quickstart
Roland Jax edited this page Oct 11, 2026
·
6 revisions
- Connect the adapter to eBUS.
- At least one LED should shine (HW v3.0+) — if not, switch the eBus wires.
Blinking D1 means bus activity. The adapter comes pre-adjusted; if D1 is steadily on or off, re-adjust:
-
v6.0 and newer (web interface): open
http://esp-ebus.local/configand adjustPWM(default130, min1, max255). D1 steadily on → lower the value; steadily off → raise it. -
v5.x and older (trimmer RV1; directions reversed for adapters
purchased via Elecrow):
- Turn counterclockwise to the point between blinking and steadily on.
- Turn clockwise to the point between blinking and steadily off.
- Count the turns between the two points, set the middle with D1 blinking, then disconnect and reconnect the adapter.
- Join the
esp-eBusnetwork — a configuration page opens automatically (default passwordebusebus). - Enter your WiFi SSID and password.
- After reboot,
ping esp-ebus.localshould answer (requires working mDNS on your network).
-
telnet esp-ebus.local 3334shows incoming bytes (unreadable binary = working receiver). Port 3334 is listen-only; anything sent there is discarded. In bridge mode every received byte is forwarded unfiltered; in INTERNAL firmware 3334 carries the framed event stream. - Decode messages with ebusd:
| Port | Mode | ebusd -d option |
|---|---|---|
| 3333 | Raw, read + write | -d esp-ebus.local:3333 |
| 3335 | Enhanced | -d enh:esp-ebus.local:3335 |
Bridge mode → 5. Bridge mode. Standalone operation → 6. INTERNAL firmware (current).