A command is a match rule plus decoders: read_cmd recognizes a
telegram on the bus, fields decode its data bytes into named values.
Commands ship as a JSON array; upload via HTTP (doc/commands.md) or
MQTT. They persist in LittleFS and load at restart.
This replaces the old flat format: there is no active flag and no
inline datatype/divider/digits/unit/ha_* keys. Decoding lives
in profiles, commands only reference them.
-
key (
string) — unique id, e.g."01". -
name (
string) — display name and MQTT topic base, e.g."Outside_Temperature". -
read_cmd (
hex string) —ZZ PB SB NN+ data bytes to match (see below). The source addressQQis omitted — the firmware adds its owneBUS addressautomatically. -
write_cmd (
hex string, may be empty) — header template for writes; the encoded value is appended (see below). -
interval (
seconds) —0= passive: only evaluate when the telegram appears on the bus.> 0= active: poll it ourselves everyintervalseconds. (Active =interval > 0; there is no separate flag.) -
master (
boolean) — value lives in the master part (true) or the slave answer (false). -
fields (
array, up to 4) — one entry per decoded value.
Bytes: ZZ PB SB NN D1…Dn. Example 08b509030d1700:
| Byte | Hex | Meaning |
|---|---|---|
| ZZ | 08 |
Destination (heat generator). |
| PB | b5 |
Manufacturer command class. |
| SB | 09 |
Data operation. |
| NN | 03 |
3 data bytes follow. |
| Data | 0d1700 |
Parameter id. |
On the wire the telegram starts with QQ (arbitration), followed by
your ZZ… bytes, CRC, the slave answer, and closes with SYN
(end-of-message; it releases the bus for the next participant). Logs
show both sides: ff08b509030d1700 / 031d0300.
-
name — value name within the command, e.g.
"value". -
profile — data profile reference, e.g.
"data2b_celsius". Profiles bundle datatype, divider, digits, and unit (28 built in, generated at build; seedoc/datatype_mapping.md). This is where the old inlinedatatype/divider/digits/unitkeys went. -
position — 1-based index into the data bytes (after
NN), e.g.1. -
ha_profile — Home Assistant profile reference, e.g.
"sensor_temperature"(21 built in), or""for none. This is where the old flatha_*keys went. -
raw (optional, default false) — skip sentinel-to-null mapping and
always render the raw numeric value (e.g.
UINT160xFFFF→ 65535 instead ofnull). For "no data" diagnosis; graphs will show the extreme. Seedoc/datatype_mapping.md. - min / max (optional) — per-field plausibility overrides.
write_cmd is a header template: the new value is encoded per the
field's profile and appended after the header, then sent. Only commands
with a non-empty write_cmd accept writes (HTTP values/write,
MQTT set/).
Strings (key, name, field names) live in a shared pool: max 256
strings, 2 KB total, each effectively below 255 chars. Past that,
names silently stop resolving — keep names short; ~50 commands with
one field each use roughly half the pool.
read_cmd/write_cmd hold at most 16 bytes (32 hex chars). Up to 4
fields per command.
{
"key": "01",
"name": "Outside_Temperature",
"read_cmd": "fe070009",
"write_cmd": "",
"interval": 0,
"master": true,
"fields": [
{
"name": "value",
"profile": "data2b_celsius",
"position": 1,
"ha_profile": "sensor_temperature"
}
]
}Broadcast (fe…), passive (interval 0), single value from data byte
1, decoded as DATA2B Celsius, exposed to Home Assistant as a
temperature sensor.